2 Ton Bosch IDS Light 15.2 SEER2 R-454B Heat Pump Inverter System, BOVB-24RTB-M15S, BIVA-24RXB-M15X
This AHRI-certified Bosch IDS Light system pairs the BOVB-24RTB-M15S inverter heat pump condenser with the BIVA-24RXB-M15X multi-position air handler. Together they deliver 24,000 BTU/h of cooling and 24,000 BTU/h of heating at 15.2 SEER2 and 11 EER2, the highest SEER2 rating in the IDS Light matched-system lineup. The outdoor inverter compressor adjusts its speed to the home's load, and the indoor unit includes a factory-installed A2L leak sensor and R-454B TXV. It's a ready-matched way for homeowners and contractors to bring low-GWP R-454B heat pump comfort to condos, smaller homes and additions.
Is a 2 Ton Heat Pump System the Right Size?
This system is rated for about 24,000 BTU/h in both cooling and heating modes, at a rated airflow of 780 CFM. It typically fits smaller homes, condos, townhomes, finished additions and single zones. Because the condenser modulates, it holds steady temperatures at part load instead of cycling on and off the way an oversized single-stage system does.
Square footage is only a starting point. Insulation, window area and orientation, air leakage, duct condition, local climate and your desired indoor temperature all affect the real heating and cooling load. In colder regions, the winter heating load often decides the size. A Manual J calculation confirms whether 2 tons is right and whether you'll need an electric heat kit.
Ideal for: Condos and apartments, smaller single-family homes, room additions and R-410A system replacements sized at about 2 tons.
Need more capacity? Step up to the 3 Ton Bosch IDS Light Heat Pump Inverter System, BOVB-36RTB-M15S, BIVA-36RXB-M15X for homes that need about 34,000 BTU/h.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, air leakage, window area and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | BOVB-24RTB-M15S — 2 Ton IDS Light Heat Pump Inverter Condenser |
|---|---|
| Indoor Air Handler | BIVA-24RXB-M15X — 2 Ton IDS Light Multi-Position Air Handler |
| Application | Ducted Split-System Heat Pump, Heating & Cooling |
| AHRI Rated Performance | 24,000 BTU/h Cooling / 24,000 BTU/h Heating — 15.2 SEER2, 11 EER2 (AHRI No. 215225088) |
| Refrigerant | R-454B (A2L) with Factory A2L Sensor in Air Handler |
| Compressor | Standard Inverter Compressor |
| Defrost | Demand Defrost Control |
| Electrical | 208-230V, Single Phase, 60 Hz Condensing Unit — 21.8 MCA / 35 A Max |
| Air Handler Electrical | 208-230V, Single Phase — 1.8 MCA / 15 A Max (without heat kit) |
| Line Set Size | 3/8" Liquid x 3/4" Suction (not included) |
You get both halves of the system: the BOVB-24RTB-M15S outdoor condenser and the BIVA-24RXB-M15X air handler. Both are R-454B equipment from the same Bosch series, matched under one AHRI certificate. The line set, thermostat, air filter and optional electric heat kit are sold separately. For backup heat, the 2 ton air handler accepts the 5 kW EHK-05B, 7.5 kW EHK-08B or 10 kW EHK-10B Bosch breakered heat strip.
Condensing Unit & Air Handler Features
BOVB-24RTB-M15S Outdoor Condensing Unit
- Standard inverter compressor that adjusts output to the load
- Electronic expansion valve (EEV) for precise refrigerant control
- Heating operation down to 3°F outdoor temperature
- Cooling operation up to 120°F outdoor temperature
- Demand Defrost Control with coil and ambient thermistors
- Compressor crankcase heater for cold-weather starts
- High pressure switch and low pressure transducer
- High/low voltage and over-current protection
- Compact 28" x 28" footprint, 122 lbs. net
- Line runs up to 100 ft with 50 ft of elevation difference
BIVA-24RXB-M15X Multi-Position Air Handler
- Factory-installed A2L refrigerant leak sensor
- Factory-installed R-454B TXV metering device
- All-aluminum, 4-row evaporator coil for corrosion resistance
- 1/5 HP PSC blower with three selectable speeds
- Upflow or horizontal right standard; converts to horizontal left or downflow
- Cabinet sealed to 2% or less air leakage at 1.0" w.c.
- Integrated tool-less filter rack for an 18" x 20" filter
- Polymer horizontal and vertical drain pans with UV inhibitor
- Works with standard 24 VAC heat pump thermostats
- 46-1/2" tall cabinet, 127 lbs. net
Specifications & Manuals
Product documentation includes condenser and air handler technical specifications, installation instructions, parts lists, warranty information and the Bosch product catalog to help with equipment selection, installation and service.
Frequently Asked Questions
Is the 2 ton BOVB-24RTB-M15S and BIVA-24RXB-M15X system AHRI certified?
Yes. This pairing is listed under AHRI Reference No. 215225088 at 15.2 SEER2 and 11 EER2. Utilities and rebate programs often ask for an AHRI certificate to verify a matched system's efficiency.
How does the 2 ton system compare with the 3 ton IDS Light system?
The 2 ton system delivers 24,000 BTU/h at 15.2 SEER2. The 3 ton BOVB-36RTB-M15S / BIVA-36RXB-M15X system delivers 34,200 BTU/h cooling and 34,600 BTU/h heating at 14.3 SEER2. Both use the same cabinet footprints and the same 3/8" x 3/4" line set sizes.
What else do I need to buy to complete the installation?
The system includes the outdoor condenser and the indoor air handler. Plan to buy a 3/8" x 3/4" line set, a 24 VAC heat pump thermostat, an 18" x 20" air filter, a condenser pad, electrical disconnects and wire. Add a heat kit if your climate requires backup heat.
Do I need an electric heat kit with this 2 ton system?
It depends on your climate and heating load. The heat pump operates down to 3°F outdoors, but many installers add a 5, 7.5 or 10 kW Bosch EHK-B kit for supplemental and emergency heat. Those three sizes are the ones Bosch approves for the 2 ton air handler.
Can I reuse my old R-410A line set with this system?
Bosch's installation instructions say lines previously used with another refrigerant, such as R-410A, should be replaced. New lines must be correctly sized, free of leaks and contamination, and brazed rather than soldered.
Who should install the Bosch IDS Light system?
Bosch requires installation by a licensed HVAC contractor certified to handle A2L refrigerants like R-454B. Professional installation and product registration within 90 days also qualifies the system for Bosch's 90-day labor allowance on covered repairs.