decor decor

Summary

Product #180554: $4,299.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Crating :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 47288 / 3 Ton Bosch IDS Light Heat Pump Inverter Condenser, BOVB-36RTB-M15S (52202) -- 1
  • 45526 / 3 Ton Bosch IDS Light R-454B Air Handler, BIVA-36RXB-M15X (52205) -- 1
4299
$4,299.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
BOVB-36RTB-M15S, BIVA-36RXB-M15X | Matched 3-Ton Inverter Comfort Built for the Mid-Size Family Home

3 Ton Bosch IDS Light 14.3 SEER2 R454B Heat Pump Inverter System BOVB-36RTB-M15S, BIVA-36RXB-M15X

· SKU 180554 · AHRI 217895618 · Split System
SEER2
14.3
Capacity
36,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $6,175.00

Our price:

$4,755.00

Sale price:

$4,299.00
You save $1,876.00!
  • SKU: 180554
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.3
  • Product Type:
    Split System
  • Tonnage:
    3
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    19.5"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
Crating
  • Crating
  • 5kW Bosch Heat Strip, EHK-05A/WHE0502X
  • 8kW Bosch Heat Strip, EHK-08/WHE0802X
  • 10kW Bosch Heat Strip, EHK-10A/WHE1002X
  • 15kW Bosch Breakered Heat Strip, EHK-15B/WHE1502BX
  • 20kW Bosch Breakered Heat Strip, EHK-20B/WHE2002BX
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Bosch WiFi Touchscreen 4H/2C Thermostat, BCC110
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2 Ton Bosch IDS Light Heat Pump Inverter Condenser, BOVB-36RTB-M15S
  • 3 Ton Bosch IDS Light R-454B Air Handler, BIVA-36RXB-M15X
Adding to cart… The item has been added

3 Ton Bosch IDS Light 14.3 SEER2 R-454B Heat Pump Inverter System, BOVB-36RTB-M15S, BIVA-36RXB-M15X

This Bosch IDS Light system is a matched set for mid-size homes: the BOVB-36RTB-M15S 3 ton inverter heat pump and the BIVA-36RXB-M15X air handler. Under AHRI Reference No. 215225096, the pair is rated at 34,200 BTU/h cooling and 34,600 BTU/h heating, so it delivers slightly more heat than cooling, which suits mixed climates with real winters. It runs on R-454B with an outdoor electronic expansion valve and an indoor factory TXV and A2L sensor. That makes it a clean, code-ready upgrade for families replacing an aging 3 ton R-410A heat pump.

Is a 3 Ton Heat Pump System the Right Size?

A 3 ton system fits homes with a calculated load of about 34,000 BTU/h, typically a mid-size family home or a larger single-level house. Its rated airflow of 1,160 CFM works out to roughly 340 CFM per ton, well within Bosch's required range. The inverter condenser runs below full speed for most of the year, which helps with humidity control during long cooling days.

Before you commit, check that the existing ductwork can carry about 1,160 CFM without excessive static pressure. Undersized returns are the most common problem in 3 ton changeouts. Also weigh insulation, window exposure and the coldest local design temperature, since heating load drives sizing in many climates.

Ideal for: Mid-size single-family homes, ranch-style houses, larger condos and 3 ton heat pump changeouts converting to R-454B.

Need more capacity? Step up to the 4 Ton Bosch IDS Light Heat Pump Inverter System, BOVB-60RTB-M15S, BIVA-48RXB-M15X for homes with loads near 46,000 BTU/h.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, air leakage, window area and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit BOVB-36RTB-M15S — 3 Ton IDS Light Heat Pump Inverter Condenser
Indoor Air Handler BIVA-36RXB-M15X — 3 Ton IDS Light Multi-Position Air Handler
Application Ducted Split-System Heat Pump, Heating & Cooling
AHRI Rated Performance 34,200 BTU/h Cooling / 34,600 BTU/h Heating — 14.3 SEER2, 10 EER2 (AHRI No. 215225096)
Refrigerant R-454B (A2L) with Factory A2L Sensor in Air Handler
Compressor Standard Inverter Compressor
Defrost Demand Defrost Control
Electrical 208-230V, Single Phase, 60 Hz Condensing Unit — 25.8 MCA / 40 A Max
Air Handler Electrical 208-230V, Single Phase — 3.3 MCA / 15 A Max (without heat kit)
Line Set Size 3/8" Liquid x 3/4" Suction (not included)

This package ships the BOVB-36RTB-M15S 3 ton condenser together with the BIVA-36RXB-M15X air handler. The two are matched for capacity, airflow and metering, so there's no guesswork about compatibility. The outdoor unit's two-row coil and the indoor unit's 1/3 HP three-speed blower are sized to work together at the rated 1,160 CFM. For backup heat, the 3 ton air handler accepts Bosch breakered kits from 5 kW up to the 15 kW EHK-15B heat strip.

Condensing Unit & Air Handler Features

BOVB-36RTB-M15S Outdoor Condensing Unit

  • 34,200 BTU/h cooling and 34,600 BTU/h heating as a matched system
  • Two-row outdoor coil with 17 fins per inch
  • Inverter compressor ramps capacity with demand
  • Outdoor EEV paired with the indoor factory TXV
  • Heats from 3°F to 86°F outdoors
  • Demand Defrost Control limits unnecessary defrost cycles
  • DIP switch options for accelerated heating/cooling mode
  • Compressor crankcase heater and liquid return protection
  • 28" x 28" cabinet, 129 lbs. net
  • 5 lbs. 11 oz. R-454B charge per Bosch spec sheet

BIVA-36RXB-M15X Multi-Position Air Handler

  • 1/3 HP three-speed PSC blower with up to 1,526 CFM available
  • Factory A2L refrigerant sensor runs the blower at maximum speed if a leak is detected
  • Factory-installed R-454B TXV
  • All-aluminum, 4-row evaporator coil
  • Field convertible to downflow or horizontal left
  • Accepts Bosch EHK-05B, EHK-08B, EHK-10B and EHK-15B heat kits
  • Factory-sealed, fully insulated cabinet
  • Tool-less filter door for an 18" x 20" filter
  • Primary and secondary 3/4" NPT drain connections
  • 46-1/2" tall cabinet, 130 lbs. net

Specifications & Manuals

Product documentation includes condenser and air handler technical specifications, installation instructions, parts lists, warranty information and the Bosch product catalog to help with equipment selection, installation and service.

Frequently Asked Questions

Why is the 3 ton system rated 14.3 SEER2 when the 2 ton is 15.2?

Each size is tested as a matched pair under AHRI 210/240. As capacity rises, the ratio of coil surface to cooling output changes, which affects the seasonal efficiency number. The 3 ton pair is certified at 14.3 SEER2 and 10 EER2 while delivering about 10,000 BTU/h more capacity than the 2 ton system.

What changes when stepping up from the 2 ton IDS Light system to this 3 ton?

Capacity rises to 34,200 BTU/h cooling and 34,600 BTU/h heating, and rated airflow increases from 780 to 1,160 CFM. The outdoor coil goes from one row to two, and the air handler blower goes from 1/5 HP to 1/3 HP. Cabinet sizes and line set sizes stay the same.

What electrical circuits does this 3 ton system need?

The condenser requires a 25.8 A minimum circuit ampacity with 40 A maximum overcurrent protection. The air handler alone needs 3.3 MCA on a 15 A circuit, and that rises when a heat kit is installed. Bosch calls for time-delay fuses or HACR-type breakers.

What thermostat works with the BOVB-36RTB-M15S and BIVA-36RXB-M15X?

A standard 24 VAC heat pump thermostat works. Choose a model with 2H for one stage of electric backup heat or 3H for two stages. Browse our thermostats and controls for compatible options.

How well does the 3 ton system heat in winter?

The condenser is rated to operate in heating mode down to 3°F outdoors. As a matched system it delivers 34,600 BTU/h of nominal heating. Where design temperatures drop below what the heat pump can carry alone, a Bosch heat kit of up to 15 kW provides the balance.

How long can the line set be on this system?

Bosch allows up to 100 ft of total equivalent length using the standard 3/8" liquid and 3/4" suction lines, with up to 50 ft of vertical separation. A 5/8" suction line is listed as an optional size. See all copper line sets.