2 Ton Bosch IDS Light 15 SEER2 R-454B Multi-Position Air Handler, BIVA-24RXB-M15X
The Bosch BIVA-24RXB-M15X is the 2 ton indoor half of the Bosch IDS Light inverter heat pump system, built for R-454B and ready to install out of the box. It comes with a factory-installed A2L refrigerant sensor and a factory-installed R-454B TXV, so it's set up for today's A2L refrigerant requirements. Its all-aluminum, four-row evaporator coil resists corrosion, and a 1/5 HP three-speed PSC blower moves air through a factory-sealed cabinet rated at 2% or less air leakage. Paired with the Bosch BOVB-24RTB-M15S 2 ton inverter heat pump, it forms an AHRI-certified 15.2 SEER2 system for condos, smaller homes and additions.
Is a 2 Ton Air Handler the Right Size?
The BIVA-24RXB-M15X is rated for 24,000 BTU/h of nominal cooling and heating. It should be sized to the home's calculated load, not just its square footage. At high speed it moves up to 1,134 CFM with no external static pressure, enough to deliver the 300 to 450 CFM per ton Bosch requires for a properly operating 2 ton heat pump system.
Duct design affects real-world airflow more than any other factor. Undersized returns, long flex runs, restrictive filters and added electric heat all raise static pressure and lower delivered CFM. Confirm the load with a Manual J, check the ducts against Bosch's airflow table, and use the control board DIP switch to set the blower speed tap that delivers the correct airflow.
Ideal for: Condos and apartments, smaller single-family homes, room additions and closet, attic or crawlspace installations that need a 2 ton R-454B heat pump air handler.
Need more capacity? Step up to the 3 Ton Bosch IDS Light R-454B Air Handler, BIVA-36RXB-M15X for homes that need about 34,000 BTU/h of heating and cooling.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, static pressure, air leakage and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Indoor Unit | BIVA-24RXB-M15X — 2 Ton IDS Light Multi-Position Air Handler (Bosch Part No. 8733965419) |
|---|---|
| Matching Outdoor Unit | Sold separately — Bosch BOVB-24RTB-M15S or BOVB-36RTB-M15S IDS Light Inverter Heat Pump |
| Application | Split-System Heat Pump Air Handler — Upflow, Downflow, Horizontal Left or Right |
| Refrigerant | R-454B with Factory-Installed A2L Refrigerant Sensor |
| Metering Device | Factory-Installed R-454B TXV |
| Blower Motor | 1/5 HP PSC, 3 Selectable Speeds |
| Electrical | 208/230V, Single Phase, 60 Hz — 1.8 MCA / 15 A Max Overcurrent (without heat kit) |
| Line Connections | 3/8" Liquid / 3/4" Suction (sweat) |
| Dimensions / Weight | 21-5/8" D x 19-5/8" W x 46-1/2" H — 127 lbs. net |
This listing is for the air handler only. The outdoor heat pump, electric heat kit and air filter are sold separately. Bosch's AHRI table rates the BIVA-24RXB-M15X at 15.2 SEER2 with either the BOVB-24RTB-M15S or the BOVB-36RTB-M15S 3 ton condenser. For supplemental or emergency heat, the 2 ton cabinet accepts Bosch breakered kits up to 10 kW, such as the 5 kW EHK-05B heat strip or the 10 kW EHK-10B heat strip.
Air Handler Features & Matched Heat Pump Options
BIVA-24RXB-M15X IDS Light Air Handler
- 24,000 BTU/h nominal cooling and heating capacity
- Factory-installed A2L refrigerant sensor for R-454B leak detection
- Factory-installed R-454B thermostatic expansion valve (TXV)
- All-aluminum, 4-row evaporator coil with 4.02 sq. ft. face area
- 1/5 HP PSC blower motor with three selectable speed taps
- Factory-sealed cabinet tested to 2% or less air leakage at 1.0" w.c.
- Upflow or horizontal right standard; field convertible to horizontal left or downflow
- Polymer horizontal and vertical drain pans with UV inhibitor
- Integrated filter rack with tool-less door for an 18" x 20" filter
- Fully insulated cabinet, slide-out blower and coil, AHRI and ETL listed
Matched BOVB Heat Pumps & Accessories
- BOVB-24RTB-M15S 2 ton inverter heat pump: 15.2 SEER2 AHRI rating
- BOVB-36RTB-M15S 3 ton inverter heat pump: 15.2 SEER2, 12 EER2 AHRI rating
- Works with most standard 24 VAC heat pump thermostats
- Accepts Bosch EHK-05B, EHK-08B (7.5 kW) and EHK-10B heat kits
- Every Bosch EHK heat kit includes a circuit breaker for each element
- Electrical entry through the top or either side of the cabinet
- 3/4" NPT primary and auxiliary drain connections
- Requires 25" of front clearance for filter and coil service
- Field-supplied air filter required — shop HVAC filtration
- Pair with a compatible heat pump thermostat
Specifications & Manuals
Product documentation includes technical specifications, airflow and heater kit data, installation instructions, a spare parts list, warranty terms and the Bosch product catalog to help with equipment selection, installation and service.
Frequently Asked Questions
Which outdoor heat pumps are matched with the BIVA-24RXB-M15X?
Bosch's AHRI table pairs this air handler with the BOVB-24RTB-M15S 2 ton and BOVB-36RTB-M15S 3 ton IDS Light inverter heat pumps. Both combinations are rated at 15.2 SEER2 and 24,000 BTU/h of cooling.
How does the 2 ton BIVA-24RXB-M15X compare with the 3 ton BIVA-36RXB-M15X?
Both share the same 46-1/2" tall cabinet, 18" x 20" filter size and 3/4" suction connection. The 2 ton model uses a smaller 1/5 HP blower (versus 1/3 HP), draws less power (1.8 MCA versus 3.3 MCA) and accepts heat kits up to 10 kW instead of 15 kW.
What does the factory-installed A2L refrigerant sensor do?
It watches for R-454B leaks inside the air handler. If it detects a leak, the blower runs at maximum speed to disperse the refrigerant and the compressor stops. Bosch states that the sensor must stay powered at all times and has a 15-year service life.
What size electric heat kit fits the 2 ton air handler?
Bosch lists the EHK-05B (5 kW), EHK-08B (7.5 kW) and EHK-10B (10 kW) breakered heat kits for the 2 ton cabinet. The 15 kW and 20 kW kits are not approved for this size.
Does the BIVA-24RXB-M15X come with an air filter?
No. Filters are field supplied. The cabinet has a built-in filter rack with a tool-less door that takes an 18" x 20" filter. Bosch recommends sizing filtration for no more than 300 feet per minute of air velocity.
Can this air handler be installed in a closet?
Yes, provided Bosch's clearance and minimum room area requirements for R-454B are met. Leave 25" of clearance in front of the unit for filter and coil maintenance, and check the installation instructions for the minimum room area based on the system's total refrigerant charge.
Bosch IDS Light Air Handler Technical Specifications
Bosch IDS Light Air Handler Installation Instructions
Bosch IDS Light Air Handler Parts List
Bosch Catalog