decor decor

Summary

Product #37051: $125.00
  • 43207 / ALL Three R410A, R404A, R22 Gauge with 1/4" SAE Fitting & Hose (26033) -- 1
  • 43722 / Freon R410A Refrigerant 28.2oz Disposable One Step Can (37052) -- 1
125
$125.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
R-410A Can + Gauge & Hose | Quick 1/4″-Port Top-Offs Without a Manifold Setup

Freon R410A Refrigerant 28.2oz Disposable One Step Can With Gauge & Hose 1/4" Connection

· SKU 37051
Refrigerant Type
R-410A
Average Rating:
List price: $280.00

Our price:

$175.00

Sale price:

$125.00
You save $155.00!
  • SKU: 37051
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • Refrigerant Type:
    R-410A
  • ALL Three R410A, R404A, R22 Gauge with 1/4" SAE Fitting & Hose
  • Freon R410A Refrigerant 28.2oz Disposable One Step Can
Adding to cart… The item has been added

R-410A Refrigerant 28.2 oz One-Step Can with Gauge & Hose — 1/4″ Connection

This kit adds refrigerant without a manifold setup. It includes a 28.2 oz (1.8 lb) disposable one-step can of R-410A, a reusable gauge, and a charging hose with a 1/4″ connection. Connect the hose to the can and to the system's service port, press the button, and watch the gauge while you top off. It's built for ducted R-410A air conditioners and heat pumps with a 1/4″ service port. For a ductless unit, the mini split R-410A recharge kit adds the 5/16″ adapter.

Is the R-410A Gauge Kit the Right Choice?

This kit suits a technician who needs to add a small amount of R-410A to a central split system or packaged heat pump, such as finishing a charge after a repair, without unpacking a full manifold set. The gauge shows pressure as you charge, and you keep it for the next can.

It's also a practical starter kit. Buy it once, then refill with the less expensive can-only version. The contents are plain R-410A with no sealant or dye, so it's the right choice once a leak has been repaired.

Ideal for: Topping off ducted R-410A central air conditioners and heat pumps with a 1/4″ service port.

Need more capacity? Step up to the R-410A 25 lb Jug, Factory Sealed for full system charges.

Charging amounts are general guidelines only. Actual requirements depend on system size, line-set length, ambient conditions, and the amount of refrigerant lost. For use by qualified HVAC/R technicians. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Refrigerant Can R-410A Refrigerant 28.2 oz (1.8 lb) Disposable One-Step Can
Gauge & Hose R-410A / R-404A / R-22 Gauge with 1/4″ SAE Fitting & Hose (reusable)
Service Connection 1/4″ SAE
Charging Method One-step push-button charging
Additives None (no leak stop or dye)
Best For Ducted R-410A split systems and heat pumps
Mini Split Use Requires a 5/16″-to-1/4″ adapter (not included)
Global Warming Potential 2,088

Refrigerant and charging tools come in one box, so a quick R-410A top-off on a ducted system doesn't require a full manifold setup.

Refrigerant & Gauge Kit Features

R-410A Refrigerant Can

  • 28.2 oz (1.8 lb) of R-410A
  • No leak stop or dye
  • Disposable one-step can
  • For R-410A air conditioners and heat pumps
  • Sized for top-offs and finishing a charge
  • Compact for ladders and rooftops
  • Can-only refills sold separately
  • No cylinder deposit or return
  • Good after a completed leak repair
  • For qualified HVAC/R technicians

One-Step Gauge & Hose

  • Reusable gauge included
  • Gauge reads R-410A, R-404A, and R-22
  • Charging hose with 1/4″ connection
  • Fits standard 1/4″ service ports
  • Connect, press, and charge
  • Watch pressure while you charge
  • No manifold setup for small top-offs
  • Reuse with future R-410A cans
  • Good starter kit before buying refills
  • Compact enough for a service bag

Frequently Asked Questions

How do I use the one-step can and gauge?

Connect the charging hose to the can and to the system's 1/4″ service port, then press the button to add refrigerant while watching the gauge. Follow the equipment manufacturer's charging procedure.

What gauge comes with this kit?

It includes the R-410A / R-404A / R-22 gauge with 1/4″ SAE fitting and hose, which you can reuse after the can is empty.

Can I use this on a ductless mini split?

Only with an adapter, because mini splits have a 5/16″ port. Add the 5/16″ female to 1/4″ male adapter or choose the complete mini split R-410A kit.

My system is still leaking. Should I use this kit?

Fix the leak first, or use the R-410A leak stop kit with gauge and hose, which seals small leaks up to 300 microns and adds UV dye.

How do I tell if my system uses R-410A?

Check the data plate on the outdoor unit. Only add R-410A to equipment rated for it. R-32 and R-454B systems need their own refrigerant.

What's a good full manifold for more detailed diagnostics?

For superheat and subcooling work beyond a quick top-off, the NAVAC analog manifold gauge covers R-410A, R-22, R-32, and R-454B.