decor decor

Summary

Product #37292: $135.00
  • 43207 / ALL Three R410A, R404A, R22 Gauge with 1/4" SAE Fitting & Hose (26033) -- 1
  • 43882 / Leak Stop Freon R410A Refrigerant 28.2oz Disposable One Step Can (37293) -- 1
135
$135.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
R-410A Leak Stop + Gauge | Seal, Charge & Dye-Trace in One Hookup

Leak Stop Freon R410A Refrigerant 28.2oz Disposable One Step Can With Gauge & Hose 1/4" Connection

· SKU 37292
Refrigerant Type
R-410A
Average Rating:
List price: $275.00

Our price:

$185.00

Sale price:

$135.00
You save $140.00!
  • SKU: 37292
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • Refrigerant Type:
    R-410A
  • ALL Three R410A, R404A, R22 Gauge with 1/4" SAE Fitting & Hose
  • Leak Stop Freon R410A Refrigerant 28.2oz Disposable One Step Can
Adding to cart… The item has been added

R-410A Leak Stop & UV Dye Refrigerant — 28.2 oz One-Step Can with Gauge & Hose, 1/4″ SAE

This kit seals the leak, recharges the system, and marks the leak, all from one can. It's a 28.2 oz (1.8 lb) disposable can of R-410A blended with a polymer-free leak stop and UV dye, packaged with a reusable push-button gauge and a charging hose with a 1/4″ SAE fitting. The leak stop seals small leaks up to 300 microns as the refrigerant goes in, so there's no separate injector. If the leak is too large to seal, the dye shows where it is under a UV light. Already carry your own gauges? The R-410A leak stop can-only refill costs less.

Is the Leak Stop Gauge Kit the Right Choice?

This is the kit for a ducted R-410A air conditioner or heat pump that keeps losing a little charge from a slow leak. Instead of injecting sealant and refrigerant separately, you connect one hose to the system's 1/4″ service port, press the button, and watch the gauge while sealant, dye, and refrigerant go in together.

The leak stop is made for small leaks up to 300 microns. A larger leak needs a real repair, and that's where the UV dye earns its keep: it circulates with the refrigerant and glows at the leak point under UV light, saving time on the next visit. The gauge can be reused once the can is empty.

Ideal for: Ducted R-410A split systems and heat pumps with a 1/4″ service port that have a minor leak and need a top-off.

Need more capacity? Step up to the R-410A 25 lb Jug, Factory Sealed for full system charges once the leak has been repaired.

Leak stop performance depends on leak size and location; leaks larger than 300 microns require mechanical repair. Charging amounts vary with system size, line-set length, and ambient conditions. For use by qualified HVAC/R technicians. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Refrigerant Can R-410A with Leak Stop & UV Dye, 28.2 oz (1.8 lb) One-Step Can
Gauge & Hose R-410A / R-404A / R-22 Push-Button Gauge with 1/4″ SAE Fitting & Hose (reusable)
Leak Stop Polymer-free formula, seals leaks up to 300 microns
Leak Detection UV dye, visible with UV detection tools
Valve / Connection 1/4″ SAE self-sealing valve; connects to 1/4″ service ports
Best For Ducted R-410A split systems and heat pumps
Cylinder DOT-39 approved disposable can
Standard / Origin Meets AHRI 700 • Made in USA

One box handles three jobs: sealing a small leak, topping off the charge, and leaving a dye trail in case the leak needs a mechanical repair later.

Leak Stop Refrigerant & Gauge Kit Features

R-410A Leak Stop & UV Dye Blend

  • R-410A pre-blended with leak stop and UV dye
  • Polymer-free leak stop formula
  • Seals small leaks up to 300 microns
  • No separate injector needed
  • Seal and recharge in one service step
  • UV dye marks leaks too large to seal
  • Works with standard UV detection tools
  • 28.2 oz (1.8 lb) net refrigerant
  • Meets AHRI 700 standards
  • Made in USA

Push-Button Gauge & Hose

  • Reusable push-button charging gauge
  • Gauge reads R-410A, R-404A, and R-22
  • Charging hose with 1/4″ SAE fitting
  • Connects to standard 1/4″ service ports
  • Monitor pressure while you charge
  • 1/4″ SAE self-sealing valve on the can
  • DOT-39 approved disposable cylinder
  • No manifold setup needed for a top-off
  • Gauge works with future refill cans
  • Compact for the service truck

Frequently Asked Questions

How large a leak can the leak stop seal?

The polymer-free formula seals small leaks up to 300 microns. Larger leaks need a mechanical repair; the UV dye helps you find them.

Do I need a separate sealant injector?

No. The leak stop and dye are already blended into the R-410A, so they go in with the refrigerant through the included hose.

How do I find the leak with the UV dye?

After charging, run the system so the dye circulates, then scan joints, coils, and fittings with a UV light. The dye glows where refrigerant escapes. You can confirm it with an electronic tool such as the TradePro refrigerant leak detector.

Can this kit charge a mini split?

Not without an adapter, because mini splits use a 5/16″ service port. The mini split R-410A leak stop kit includes the 5/16″-to-1/4″ adapter.

What if I only need refrigerant without leak stop?

For a leak-free system, choose the standard R-410A 28.2 oz can with gauge and hose, which has no sealant or dye.

Can this go into an R-22, R-32, or R-454B system?

No. This product is R-410A and must only be used in R-410A equipment. Check the refrigerant type on the outdoor unit's data plate before charging.