5 Ton Rheem Select 15.2 SEER2 R454B Two Stage Heat Pump System WP14AY60AJ2NA, RH2TY6024STANNJ
The flagship of the Rheem Select heat pump lineup, this 5 ton system pairs the WP14AY60AJ2NA, the only Select model with a two-row condenser coil and factory crankcase heater, with the 24.5" RH2TY6024STANNJ air handler. Listed at 15.2 SEER2 under AHRI #214803219 on R-454B refrigerant, it brings two-stage, maximum-capacity residential comfort to large homes at a Select-series price.
Is a 5 Ton Heat Pump System the Right Size?
At a nominal 60,000 BTU/h, this system is meant for large homes, houses with extensive glass or high ceilings, and hot climates where smaller systems cannot keep up during peak conditions.
Because it is the largest size, it is also the easiest to oversize. Two-stage operation helps by running on low stage when full capacity is not needed, but sizing should still come from a Manual J calculation, and ductwork must be generous on both supply and return.
Ideal for: Large single-family homes, homes with high ceilings or lots of glass, hot-climate properties with heavy cooling demand, and replacement of an existing 5 ton heat pump.
Need less capacity? Compare the 4 Ton Rheem Select 14.3 SEER2 R454B Two Stage Heat Pump System WP14AY48AJ2NA, RH2TY4821STANNJ if your load calculation comes in below 5 tons.
Recommended system sizes are general guidelines only. Actual heating and cooling requirements depend on insulation, climate, windows, ductwork, ceiling height, and occupancy. A Manual J load calculation is the best way to confirm sizing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | WP14AY60AJ2NA — 5 Ton R-454B Two-Stage Heat Pump |
|---|---|
| Indoor Air Handler | RH2TY6024STANNJ — 5 Ton Two-Stage Multipoise Air Handler with TXV |
| System Rating | 15.2 SEER2, 60,000 BTU/h Nominal, AHRI #214803219 |
| Refrigerant | R-454B (A2L, Low GWP) |
| Compressor | Two-Stage Scroll Compressor |
| Warranty | 5-Year Limited Parts & 5-Year Compressor (WP14AY Outdoor Unit) |
| Electrical | 208/230V, Single Phase, 60 Hz Heat Pump — MCA 33 A, Max Breaker 50 A |
| Air Handler Electrical | 208-240V, Single Phase — 3/4 HP Constant Torque Motor, 24.5" Cabinet |
The WP14AY60AJ2NA steps up to a 26" fan, a two-row coil, a 194 oz R-454B charge, and a factory-standard crankcase heater, all unique to this size in the Select line. Indoors, the RH2TY6024STANNJ uses a 24.5" cabinet for higher airflow. Plan for a 7/8" x 3/8" copper line set, a 50 A maximum breaker, a properly sized air filter, and up to a 20 kW Rheem heat strip.
Heat Pump & Air Handler Features
WP14AY60AJ2NA Outdoor Heat Pump
- Two-stage scroll compressor (25 RLA)
- Two-row 7 mm copper condenser coil
- 26" three-blade fan with 1/5 HP motor
- Factory-standard compressor crankcase heater
- 194 oz R-454B factory charge for 15 feet of line
- Fully louvered steel cabinet
- PlusOne® Refrigerant Detection System
- Inverted reversing valve
- 39-1/8" H x 35-1/2" W x 35-1/2" L cabinet, 303 lbs shipping
- 74 dBA weighted sound power rating
RH2TY6024STANNJ Multi-Position Air Handler
- 5 ton rating in a 24-1/2" wide cabinet
- 3/4 HP two-stage constant torque motor
- Nominal airflow of 1,200 CFM low / 1,600 CFM high
- 55-1/2" cabinet height
- 7/8" vapor and 3/8" liquid sweat connections
- Factory TXV and A2L refrigerant sensor
- Upflow, downflow, or horizontal installation
- Less than 2% cabinet air leakage at 1" H2O
- Slide-out blower design
- Accepts heat strips up to 20 kW on this listing
Specifications & Manuals
Refer to the WP14AY specifications for 5 ton electrical, weight, and line sizing data, the charging chart for field charging, and the RH2TY literature for 24.5" cabinet dimensions and airflow.
Frequently Asked Questions
What size home needs the 5 ton WP14AY60AJ2NA system?
Homes with a load near 60,000 BTU/h, typically large single-family homes or hot-climate homes with heavy cooling demand. A Manual J calculation is essential at this size.
What makes the WP14AY60AJ2NA different from the smaller Select models?
It is the only WP14AY with a two-row condenser coil, a 26" fan, and a factory-standard crankcase heater, and it carries the largest charge at 194 oz.
How much does the 5 ton Select outdoor unit weigh?
Rheem lists a shipping weight of 303 lbs. Plan for a properly rated pad and help setting the unit.
Why does this system use the 24.5 inch RH2TY6024STANNJ?
The wider cabinet supports 5 ton airflow, with nominal airflow of 1,200 CFM on low stage and 1,600 CFM on high stage.
What breaker does the 5 ton WP14AY60AJ2NA require?
Rheem lists a 33 A minimum circuit ampacity and a 50 A maximum overcurrent protection.
Should I choose 5 tons if my load is between 4 and 5?
Two-stage operation helps a 5 ton system run efficiently on low stage, but oversizing still affects comfort and humidity. Request a quote and our team can help you decide.
WP14AY Technical Specifications
RP14AY, WP14AY, RP15AY Installation Instructions
WP14AY Submittal Sheet
WP14AY Warranty Card
WP14AY Brochure
RH2TY Technical Specifications
RH2TY Installation Instructions
Rheem Warranty Certificate