5 Ton Rheem 15.2 SEER2 R-454B Two Stage Heat Pump System RP14AY60AJ2NA, RH2TY6024STANNJ
This is the highest-rated match in the RP14AY heat pump family. Pairing the 60,000 BTU RP14AY60AJ2NA with the wide-body RH2TY6024STANNJ air handler produces a certified 15.2 SEER2 system rather than the 14.3 SEER2 that the narrower coils yield, because the 24.5 inch cabinet carries enough evaporator surface to lower the refrigerant-side temperature difference. If the mechanical space can accept a 24.5 inch wide cabinet, this is the efficient way to buy five tons of Rheem heat pump capacity.
Is a 5 Ton Heat Pump System the Right Size?
Five tons produces 60,000 BTU per hour and generally serves 2,300 to 3,000 square feet of conditioned space in a hot climate. It is the largest residential split capacity Rheem builds in this series, and above it the correct answer is usually two systems rather than one larger one.
A five ton system needs roughly 2,000 CFM of airflow, which is more than many existing duct systems were ever designed to carry. Before committing, check return air free area, trunk line sizing and filter face velocity; a five ton system strangled by a 3.5 ton duct layout will run high static, use more energy and deliver less capacity than a properly ducted four ton. The wide 24.5 inch cabinet used here helps, since its larger coil and return opening reduce pressure drop across the equipment itself.
Ideal for: Large single-family homes, two-story houses on a single system, open-plan builds with high ceilings, and light commercial spaces in the 2,300 to 3,000 square foot range that have duct capacity to match.
Tight on closet width? The 5 Ton RP14AY60AJ2NA, RH2TY6021STANAJ system uses the same outdoor unit with a 21.5 in. air handler and a 14.3 SEER2 rating. Want more efficiency instead? Compare the 5 Ton Rheem RP15AY60AJ2NA system.
Recommended capacity ranges are general guidelines only. Actual system requirements depend on insulation, window area, duct design, air infiltration, and local climate. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | RP14AY60AJ2NA — 5 Ton / 60,000 BTU Two-Stage Heat Pump |
|---|---|
| Indoor Air Handler | RH2TY6024STANNJ — 24.5 in. Wide Multiposition Air Handler |
| Application | Residential and Light Commercial Split System Heat Pump |
| Refrigerant | R-454B Low GWP (A2L) |
| Compressor | Two-Stage Scroll |
| Rated Efficiency | 15.2 SEER2 as matched |
| AHRI Reference | 214803216 |
| Condenser Electrical | 208/230V, Single Phase, 60 Hz — 33 MCA / 50 A Max Fuse or Breaker |
| Air Handler Electrical | 208/240V, Single Phase, 60 Hz |
| Line Set Connections | 3/8 in. Liquid, 7/8 in. Vapor |
The 15.2 SEER2 rating belongs to this specific pairing, not to the outdoor unit alone. Substituting a narrower air handler changes the certified rating, which is why the AHRI reference number above is tied to the RH2TY6024STANNJ. Run a 7/8 in. x 3/8 in. copper line set and set the condenser on a 40 x 40 hurricane-rated condenser pad.
Condenser & Air Handler Features
RP14AY60AJ2NA Outdoor Heat Pump
- 60,000 BTU two-stage scroll compressor, the largest capacity in the RP14AY series
- Low stage handles shoulder-season load at reduced sound and power draw
- Largest condenser coil and cabinet in the lineup for better heat rejection at high ambient
- Inverted reversing valve with gravity-assisted shifting for dependable defrost cycles
- PlusOne Triple Service Access keeps the 15 in. corner opening even on the largest cabinet
- PlusOne Expanded Valve Space for recovery, evacuation and charging equipment
- Integrated PlusOne Refrigerant Detection System with a single A2L sensor and mitigation board
- Works with conventional 24V two-stage heat pump thermostats
- R-454B refrigerant meets the EPA 2025 GWP limit of 700 for residential HVAC
- 33 amp minimum circuit ampacity with 50 amp maximum overcurrent protection
RH2TY6024STANNJ Air Handler
- 24.5 in. wide cabinet, the widest RH2TY body, with the largest coil face area
- Extra coil surface is what lifts this match to a 15.2 SEER2 certified rating
- 3/4 HP constant-torque ECM blower sized for full five-ton airflow
- 25 x 20 in. filter opening lowers face velocity and extends filter life
- Accepts field-installed heat kits to 21.6 kW at 208V or 28.8 kW at 240V
- Multiple-circuit heat kit configurations available for large auxiliary heat loads
- Four-way convertible for upflow, downflow, horizontal left and horizontal right
- Aluminum fin and internally grooved aluminum tube coil construction
- 1.0 in. foil-faced insulation with under 2 percent cabinet leakage per ASHRAE 193
- Factory-integrated A2L refrigerant detection with automatic system shutdown
Specifications & Manuals
Because the certified efficiency of this package depends on the specific outdoor and indoor pairing, the technical specifications and submittal sheets for both units are provided together, along with installation instructions, the RP14AY brochure, and Rheem warranty terms. The RH2TY documents include the airflow and electric heat kit tables for the 24.5 in. cabinet.
Frequently Asked Questions
Why is this 5 ton match rated 15.2 SEER2 when the rest of the line is 14.3?
Efficiency is certified for the pair, not the condenser alone. The 24.5 in. RH2TY6024STANNJ carries more coil face area than the narrower cabinets, which reduces the temperature difference the compressor has to work against and raises the certified rating to 15.2 SEER2.
How wide is the RH2TY6024STANNJ air handler?
It uses the 24.5 in. wide RH2TY cabinet. Confirm closet or platform width plus service clearance against the dimensional drawings in the submittal sheet before ordering, since this is the widest body in the family.
What is the difference between this system and SKU 179708?
Same RP14AY60AJ2NA outdoor unit. SKU 179708 substitutes the 21.5 in. RH2TY6021STANAJ air handler for tighter mechanical spaces, and that narrower coil produces a 14.3 SEER2 certified rating instead of 15.2.
What size home needs a 5 ton heat pump?
Generally 2,300 to 3,000 square feet in a warm climate, though high ceilings, large glass areas and poor insulation can push a smaller home into this range. Above roughly 3,000 square feet, two systems usually outperform one large one.
What electrical service does the RP14AY60AJ2NA require?
208/230V single phase, 60 Hz, with a 33 amp minimum circuit ampacity and 50 amp maximum overcurrent protection. Auxiliary electric heat runs on its own circuits, and a large kit in this cabinet can require multiple circuits.
Can the RH2TY6024STANNJ be installed in a downflow application?
Yes. It converts in the field to upflow, downflow, horizontal left or horizontal right. Downflow installations over a combustible floor require the appropriate subbase and must follow the installation instructions and local code.
RP14AY Technical Specifications
RP14AY Brochure
RP14AY Installation Instructions
RP14AY Submittal Sheet
RH2TY Technical Specifications
RH2TY Installation Instructions
RH2TY Submittal Sheet
Rheem Warranty Certificate