decor decor

Summary

Product #179374: $5,299.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 41943 / 5 Ton Rheem Two Stage R454B Air Handler RH2TY6024STANNJ (179311) -- 1
  • 41964 / 5 Ton Rheem Two Stage R454B Heat Pump Condenser RP15AY60AJ2NA (179332) -- 1
5299
$5,299.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
RP15AY60AJ2NA, RH2TY6024STANNJ | Top-of-Line 5 Ton Two-Stage Heat Pump for Large Homes

5 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY60AJ2NA, RH2TY6024STANNJ

· SKU 179374 · AHRI 215415470 · Split System
SEER2
15.2
Capacity
60,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $6,299.00

Sale price:

$5,299.00
You save $1,000.00!
  • SKU: 179374
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    5
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    24.5"
  • AHRI Number:
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • 15 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RH1PY, RH2TY, RH2VY, RXBH-1724A15J-1, WRX1502BI
  • 20 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724A20J-1, WRX2002BI
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • Honeywell T6 Pro Thermostat 3H/2C Programmable TH6320U2008
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Honeywell T10 Pro Smart Wi-Fi Touchsrceen Thermostat 3H/2C Programmable w/ Sensor, THX321WFS2001W
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 5 Ton Rheem Two Stage R454B Air Handler RH2TY6024STANNJ
  • 5 Ton Rheem 15 SEER2 Two Stage R454B Heat Pump Condenser RP15AY60AJ2NA
Adding to cart… The item has been added

5 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY60AJ2NA, RH2TY6024STANNJ

The largest system in Rheem's RP15AY two-stage lineup, this 5 ton package pairs the RP15AY60AJ2NA heat pump, built with a two-row condenser coil and 26" fan, with the 24.5" RH2TY6024STANNJ air handler. Rated 15.2 SEER2 under AHRI #215415470 on R-454B refrigerant, it delivers maximum single-system residential capacity for large homes and high-demand spaces.

Is a 5 Ton Heat Pump System the Right Size?

Rheem rates this combination at 57,000 BTU/h of cooling, 55,000 BTU/h of heating at 47°F, and 32,000 BTU/h at 17°F. It is meant for large homes, houses with extensive glass or high ceilings, and hot climates where smaller systems cannot keep up during peak conditions.

Because it is the biggest size, it is also the easiest to oversize. Two-stage operation helps by running on low stage when full capacity is not needed, but sizing should still come from a Manual J calculation. Ductwork for 5 tons must be generous on both supply and return.

Ideal for: Large single-family homes, homes with high ceilings or lots of glass, hot-climate properties with heavy cooling demand, and replacement of an existing 5 ton heat pump.

Need less capacity? Compare the 4 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY48AJ2NA, RH2TY4821STANNJ if your load calculation comes in below 5 tons.

Recommended system sizes are general guidelines only. Actual heating and cooling requirements depend on insulation, climate, windows, ductwork, ceiling height, and occupancy. A Manual J load calculation is the best way to confirm sizing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump RP15AY60AJ2NA — 5 Ton R-454B Two-Stage Heat Pump
Indoor Air Handler RH2TY6024STANNJ — 5 Ton Two-Stage Multipoise Air Handler with TXV
System Rating 15.2 SEER2, 11.7 EER2, 7.8 HSPF2, 57,000 BTU/h Cooling, AHRI #215415470
Refrigerant R-454B (A2L, Low GWP)
Compressor Two-Stage Scroll Compressor
Defrost Demand Defrost Control
Electrical 208/230V, Single Phase, 60 Hz Heat Pump — MCA 33 A, Max Breaker 50 A
Air Handler Electrical 208-240V, Single Phase — 3/4 HP Constant Torque Motor, 24.5" Cabinet

The RP15AY60AJ2NA is the only model in the series with a two-row outdoor coil, a 26" fan, and a factory-standard compressor crankcase heater. Indoors, the RH2TY6024STANNJ uses the widest 24.5" cabinet for its higher airflow. Plan for a 7/8" x 3/8" copper line set, a 50 A maximum breaker, a properly sized air filter, and up to a 20 kW breakered Rheem heat strip.

Heat Pump & Air Handler Features

RP15AY60AJ2NA Outdoor Heat Pump

  • Two-stage scroll compressor (25 RLA)
  • Two-row 7 mm copper tube condenser coil
  • 26" three-blade fan with 1/5 HP motor
  • Factory-standard compressor crankcase heater
  • 234 oz R-454B factory charge for 15 feet of line
  • Demand defrost control
  • PlusOne® Refrigerant Detection System
  • PlusOne® Expanded Valve Space and Triple Service Access
  • 39" H x 35-3/4" W x 35-3/4" L cabinet, 275 lbs
  • Optimized venturi airflow with powder-coated finish

RH2TY6024STANNJ Multi-Position Air Handler

  • 5 ton rating in a 24-1/2" wide cabinet
  • 3/4 HP two-stage constant torque motor
  • Nominal airflow of 1,200 CFM low / 1,600 CFM high
  • 55-1/2" cabinet height
  • 7/8" vapor and 3/8" liquid sweat connections
  • Factory TXV and A2L refrigerant sensor
  • Upflow, downflow, or horizontal installation
  • Less than 2% cabinet air leakage at 1" H2O
  • Slide-out blower design
  • Accepts heat strips up to 20 kW breakered on this listing

Specifications & Manuals

Refer to the RP15AY specifications for 5 ton electrical, weight, and line sizing data, and the RH2TY literature for 24.5" cabinet dimensions, airflow tables, and heater kit information.

Frequently Asked Questions

What size home needs the 5 ton RP15AY60AJ2NA two-stage system?

Homes with a load near 60,000 BTU/h, typically large single-family homes, homes with high ceilings or lots of glass, or hot-climate homes with heavy cooling demand.

What is unique about the RP15AY60AJ2NA outdoor unit?

It is the only RP15AY model with a two-row condenser coil, a 26" fan, and a factory-standard compressor crankcase heater. It also carries the largest charge at 234 oz of R-454B.

How much does the 5 ton outdoor unit weigh?

Rheem lists an operating weight of 275 lbs and a shipping weight of 282 lbs. Plan for a properly rated pad and help setting the unit.

Why does the 5 ton system use the 24.5 inch RH2TY6024STANNJ?

The wider cabinet supports the higher airflow 5 tons requires, with nominal airflow of 1,200 CFM on low stage and 1,600 CFM on high stage.

What electrical service does the 5 ton system need?

Rheem lists a 33 A minimum circuit ampacity and a 50 A maximum overcurrent protection for the RP15AY60AJ2NA. The air handler and heat strip need their own circuit.

What if my load falls between 4 and 5 tons?

Two-stage operation helps a 5 ton system run efficiently on low stage when the full load is not needed, but oversizing still affects comfort. Request a quote and our team can help you choose.

Customer Review