5 Ton Rheem 13.8 SEER2 R454B Single Stage Central System RA14AY60AJ1NA, RH1AY6024STANNJ
This Rheem Endeavor® Line Classic® system pairs the RA14AY60AJ1NA condenser with the RH1AY6024STANNJ single-stage-airflow air handler in the full-size 24.5" cabinet, AHRI certified at 13.8 SEER2 (#217232254). It's the standard 5 ton RA14AY match for homes with room for the wider air handler. The condenser includes a factory crankcase heater. It uses low-GWP R-454B with Rheem's PlusOne® Refrigerant Detection System™. It's cooling only, with Rheem electric heat strips up to 20 kW offered.
Is a 5 Ton Air Conditioning System the Right Size?
A 5 ton system provides 60,000 BTU/h of nominal cooling, the largest size for most residential split systems. It's often used in homes around 2,500–3,000+ sq. ft. as a general guide, and in some light commercial spaces.
Large single-stage systems can short-cycle if they're oversized. Confirm the load with a Manual J calculation and make sure the duct system can carry the airflow a 5 ton system needs.
Ideal for: Large single-family homes, two-story homes on one system and light commercial spaces.
Need a narrower air handler? See the 5 Ton Rheem 13.8 SEER2 R454B Single Stage Central System RA14AY60AJ1NA, RH1AY6021STANAJ with the 21" air handler.
Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | RA14AY60AJ1NA — 5 Ton Rheem Classic R454B Air Conditioner |
|---|---|
| Indoor Air Handler | RH1AY6024STANNJ Single-Stage Airflow Multipoise Air Handler (24.5" Wide) |
| Application | Cooling-Only Central Air Split System (Electric Heat Kit Optional) |
| Refrigerant | R-454B (Low-GWP A2L Refrigerant) |
| Compressor | Single-Stage Scroll Compressor |
| Metering Device | Factory-Installed Expansion Valve on Indoor Coil (TXV) |
| Electrical | 208/230V, Single Phase, 60 Hz Condensing Unit — 31 MCA / 50A Max Overcurrent |
| Air Handler Electrical | 208/240V, Single Phase — 6 MCA / 15A Max Overcurrent (No Heat Kit) |
The RA14AY60AJ1NA condenser is 45" tall on a 35.75" x 35.75" base and weighs 266 lbs (operating), with a 26" Swept Wing fan and a 76 dBA sound rating. The RH1AY6024STANNJ air handler is 24.5" wide and 55.5" tall and weighs 161 lbs, with a 3/4 HP motor. For comparison, see the 5 ton Rheem Select WA14AY60AJ1NA, RH1AY6024STANNJ system.
Condensing Unit & Air Handler Features
RA14AY60AJ1NA Outdoor Condensing Unit
- 60,000 BTU/h nominal cooling capacity
- Single-stage scroll compressor
- 76 dBA weighted sound power rating
- 7 mm copper tube condenser coil uses less refrigerant
- 192 oz. factory R-454B charge for 15 ft. of line set
- 26" three-blade Swept Wing fan with 1/5 HP motor
- 3/8" liquid and 7/8" suction front-seating service valves
- Factory-installed crankcase heater (44-103663-16)
- PlusOne® Expanded Valve Space and Triple Service Access
- 10-year conditional parts limited warranty (registration required)
RH1AY6024STANNJ Single-Stage Air Handler
- Single-stage airflow with a constant torque (ECM) motor
- 3/4 HP constant torque motor, 1,200/1,600 CFM nominal airflow
- PlusOne® Refrigerant Detection System™ with factory-installed A2L sensor
- Aluminum fins bonded to internally grooved aluminum tubing
- 4-way convertible: upflow, downflow, horizontal left or right
- 1.0" foil-faced cabinet insulation for quieter operation
- Cabinet air leakage under 2% at 1" H₂O (ASHRAE 193)
- Slide-out blower and factory leak-tested coil
- Expansion valve on indoor coil for AC or heat pump use
- Field-installed heater kits up to 20 kW with UL/cUL-listed breakers
Specifications & Manuals
Documentation includes RA14AY electrical, sound, dimensional and line-size data, condenser and air handler installation instructions, the RA14AY brochure, RH1AY airflow and heater tables and the Rheem limited warranty.
Frequently Asked Questions
What airflow range does the RH1AY6024STANNJ cover?
Rheem lists nominal airflow of 1,200 CFM on low and 1,600 CFM on high. The installer selects the speed tap and checks static pressure to match the 5 ton condenser.
Which combustible floor base fits the 24.5" RH1AY6024?
Rheem's RXHB-24 combustible floor base fits the 24.5" cabinet and is required for downflow installs on combustible floors.
Is there a two-stage airflow version of this 5 ton system?
Yes. The 5 ton RA14AY60AJ1NA, RH2TY6024STANNJ system uses the same condenser with a two-stage-airflow RH2TY air handler in the same 24.5" width.
How does this compare to the Rheem Select 5 ton RH1AY system?
The Rheem Select WA14AY60AJ1NA, RH1AY6024STANNJ system uses the same air handler with a Select-series condenser. The RA14AY60 adds Classic features like Triple Service Access and a composite base pan.
How much does the RH1AY6024STANNJ weigh?
Rheem lists a 161 lb unit weight and a 178 lb shipping weight, the heaviest in the RH1AY line.
What sound cover fits the RA14AY60AJ1NA?
Rheem lists compressor sound cover 68-23427-25 for the RA14AY60. It can help lower noise where the condenser sits near bedrooms or patios.
RA14AY Technical Specifications
RA14AY Installation Instructions
RA14AY Brochure
RH1AY Technical Specifications
RH1AY Installation Instructions
Rheem Warranty Certificate