RA14AY60AJ1NA, RH2TY6024STANNJ | Maximum Capacity, Maximum Coil — The Full 24.5-Inch Cabinet for 5 Tons of Airflow

5 Ton Rheem 13.8 SEER2 R454B Central System 13.8 RA14AY60AJ1NA, RH2TY6024STANNJ

· SKU 179339 · AHRI 215232991 · Split System
SEER2
13.8
Capacity
60,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,550.00

Sale price:

$4,510.00
You save $1,040.00!
  • SKU: 179339
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    13.8
  • Product Type:
    Split System
  • Tonnage:
    5
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    24.5"
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • 15 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RH1PY, RH2TY, RH2VY, RXBH-1724A15J-1, WRX1502BI
  • 20 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724A20J-1, WRX2002BI
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 5 Ton Rheem 14.3 SEER2 R454B Single Stage Condenser RA14AY60AJ1NA
  • 5 Ton Rheem Two Stage R454B Air Handler RH2TY6024STANNJ
Adding to cart… The item has been added

5 Ton Rheem 13.8 SEER2 R454B Central System RA14AY60AJ1NA, RH2TY6024STANNJ

This is the top of the RA14AY range: 60,000 BTU of cooling at 13.8 SEER2, built on low-GWP R-454B refrigerant and certified under AHRI reference 216011746's sibling listing 215232991. The RA14AY60AJ1NA condenser is matched here to the full-width RH2TY6024STANNJ air handler, a 24.5-inch cabinet that gives the coil and blower the face area to move 5 tons of airflow without straining. When the load calculation says 5 tons and the mechanical room has the room, this is the configuration to specify.

Is a 5 Ton Refrigeration System the Right Size?

Five tons delivers 60,000 BTU per hour and typically serves 2,400 to 3,000 square feet in a hot, humid climate. It is the largest single-phase residential split system commonly installed, and it shows up on large open-plan homes, two-story houses with a single central system, and light commercial spaces such as restaurants, salons, and small warehouses with conditioned office areas.

Five tons is also the size where a single system starts to become the wrong architecture. A 3,000 square foot two-story home served by one 5 ton system will almost always have a comfort imbalance between floors that no amount of capacity fixes. If you are replacing a 5 ton unit that never kept the second floor comfortable, the answer is usually zoning or a second system, not more tonnage.

Ideal for: Large open-plan homes, 2,400 to 3,000 square foot houses, restaurants and retail spaces, salons, and conditioned office areas within light industrial buildings.

Tight on closet width? The 5 Ton Rheem 13.8 SEER2 R454B System RA14AY60AJ1NA, RH2TY6021STANAJ delivers the same capacity in a 21-inch air handler cabinet.

Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, duct design, window area, ceiling height, occupancy, and local design conditions. Run our AC tonnage and BTU calculator, request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit RA14AY60AJ1NA — 5 Ton Endeavor Line Classic Series Air Conditioner
Indoor Air Handler RH2TY6024STANNJ Two-Stage Multiposition Air Handler
Application Residential and Light Commercial Split System, Cool Only with Field-Installed Electric Heat
Refrigerant R-454B
Nominal Capacity 60,000 BTU / 5 Tons
Rated Efficiency 13.8 SEER2
Air Handler Cabinet Width 24.5 inches
AHRI Reference Number 215232991
Electrical 208-230V, Single Phase, 60 Hz

The 24.5-inch RH2TY6024STANNJ is the widest cabinet in the RH2TY family and the preferred choice for new construction or any installation where mechanical room space is not the constraint. The larger coil face area keeps face velocity and pressure drop down at 5 ton airflow, which is exactly what you want on a system that will run long cycles through a Gulf Coast summer.

Condensing Unit & Air Handler Features

RA14AY60AJ1NA Outdoor Condensing Unit

  • 5 ton nominal capacity, 60,000 BTU, rated 13.8 SEER2
  • Largest capacity offered in the RA14AY Endeavor Line series
  • Low-GWP R-454B refrigerant, approximately 78% lower GWP than legacy blends
  • 7mm condenser copper coil for reduced charge and lighter cabinet
  • PlusOne Triple Service Access with 15-inch corner service opening
  • Patented one-box PlusOne Refrigerant Detection System
  • Outdoor unit pauses automatically if excess refrigerant is detected
  • Compatible with any 24V thermostat application
  • Sound-dampening tubing routing, fan blade design, and base pan
  • 10-year conditional parts warranty with Rheem registration

RH2TY6024STANNJ Air Handler

  • 24.5-inch cabinet, the widest in the RH2TY family
  • Maximum coil face area keeps pressure drop low at 5 ton airflow
  • 3/4 HP constant torque ECM blower motor
  • Two-stage airflow with multiple selectable speed taps
  • 1.0 inch foil-faced insulation across the cabinet
  • All-aluminum coil with internally grooved tubing
  • Factory thermal expansion valve matched to R-454B
  • 4-way convertible for upflow, downflow, and horizontal installs
  • Accepts high-capacity field-installed electric heater kits
  • Under 2% cabinet air leakage at 1-inch H2O per ASHRAE 193

Specifications & Manuals

Product documentation includes condenser and air handler technical specifications, submittal data, installation instructions, and warranty information to assist with equipment selection, permitting, installation, and service.

Frequently Asked Questions

What is the difference between the RH2TY6024STANNJ and the RH2TY6021STANAJ?

Cabinet width. The 6024 uses a 24.5-inch chassis and the 6021 uses a 21-inch chassis. Both serve 5 ton applications with the same RA14AY60AJ1NA condenser; the wider cabinet offers more coil face area, while the narrower one fits closets that cannot accommodate 24.5 inches.

Why is 5 ton rated lower than smaller sizes at 13.8 SEER2?

Each matched pair is tested and certified independently. At 5 tons the airflow and refrigerant mass flow through the coil geometry produce a 13.8 SEER2 result, compared with 14.8 at 4 tons and 15.2 through 3.5 tons. All three exceed the federal minimum for the Southeast region.

Should a 3,000 square foot two-story home use one 5 ton system?

Often not. A single system serving two floors usually leaves the upper floor warm regardless of capacity, because the load and the stack effect differ by floor. Zoning or two separate systems generally produces better comfort than adding tonnage.

Is a 5 ton system available in three-phase?

This package is 208-230V single phase. For three-phase requirements, our complete split systems category and commercial equipment sections list the models configured for 3-phase service.

How much airflow does the RH2TY6024STANNJ move?

Nominal airflow for a 5 ton application is in the range of 1,800 CFM. Speed tap selections and external static pressure curves are published in the RH2TY technical specifications linked above; the blower performs best between roughly 0.3 and 0.7 inches W.C.

What filter size does a 5 ton system require?

Filter area should be sized to the airflow rather than the cabinet. At roughly 1,800 CFM, a single undersized return filter will create high pressure drop and noise. Plan on a large-area media filter or multiple returns, and size the grille from the airflow figures in the submittal sheet.