decor decor

Summary

Product #179707: $4,499.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 41919 / 5 Ton Rheem R454B Single Stage Condenser RA14AY60AJ1NA (179287) -- 1
  • 45782 / 5 Ton Rheem Two Stage R454B Air Handler RH2TY6021STANAJ (179706) -- 1
4499
$4,499.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
RA14AY60AJ1NA, RH2TY6021STANAJ | Full 5 Tons, Three and a Half Inches Narrower — For Closets That Won't Budge

5 Ton Rheem 13.8 SEER2 R454B Central System RA14AY60AJ1NA, RH2TY6021STANAJ

· SKU 179707 · AHRI 216011746 · Split System
SEER2
13.8
Capacity
60,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,536.00

Sale price:

$4,499.00
You save $1,037.00!
  • SKU: 179707
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    13.8
  • Product Type:
    Split System
  • Tonnage:
    5
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    21"
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • 15 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RH1PY, RH2TY, RH2VY, RXBH-1724A15J-1, WRX1502BI
  • 20 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724A20J-1, WRX2002BI
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 5 Ton Rheem 14.3 SEER2 R454B Single Stage Condenser RA14AY60AJ1NA
  • 5 Ton Rheem Two Stage R454B Air Handler RH2TY6021STANAJ
Adding to cart… The item has been added

5 Ton Rheem 13.8 SEER2 R454B Central System RA14AY60AJ1NA, RH2TY6021STANAJ

Five tons of cooling in a 21-inch air handler cabinet. This Rheem Endeavor Line package pairs the RA14AY60AJ1NA condenser with the RH2TY6021STANAJ, the narrow-chassis version of Rheem's 5 ton air handler, for 60,000 BTU at 13.8 SEER2 on low-GWP R-454B refrigerant under AHRI reference 216011746. It exists for one specific and very common problem: the load calls for 5 tons, but the closet, attic platform, or mechanical chase will not take a 24.5-inch cabinet.

Is a 5 Ton Refrigeration System the Right Size?

Sixty thousand BTU per hour generally covers 2,400 to 3,000 square feet in a hot, humid climate. What makes this particular 5 ton package different is not the capacity but the packaging: the RH2TY6021STANAJ carries 4.5 to 5 ton airflow in a 21.5-inch cabinet, three and a half inches narrower than the standard 5 ton chassis.

That difference decides jobs. Condominium mechanical closets, interior chases in 1970s and 1980s construction, and attic platforms framed between trusses frequently cap out at 21 or 22 inches of usable width. On those installations the choice used to be structural modification or a downsized system that never quite kept up. This model removes that tradeoff, at the cost of slightly less coil face area than the wide-cabinet version.

Ideal for: Retrofits with fixed closet width, condominium and townhouse mechanical chases, attic platforms framed between trusses, and any 5 ton replacement where widening the opening is not practical.

Have the space for a wider cabinet? The 5 Ton Rheem 13.8 SEER2 R454B System RA14AY60AJ1NA, RH2TY6024STANNJ uses the full 24.5-inch air handler for maximum coil face area.

Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, duct design, window area, ceiling height, occupancy, and local design conditions. Run our AC tonnage and BTU calculator, request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit RA14AY60AJ1NA — 5 Ton Endeavor Line Classic Series Air Conditioner
Indoor Air Handler RH2TY6021STANAJ Two-Stage Multiposition Air Handler, Narrow Cabinet
Application Residential and Light Commercial Split System, Cool Only with Field-Installed Electric Heat
Refrigerant R-454B
Nominal Capacity 60,000 BTU / 5 Tons
Rated Efficiency 13.8 SEER2
Air Handler Cabinet Width 21 inches
AHRI Reference Number 216011746
Electrical 208-230V, Single Phase, 60 Hz

The outdoor unit is the same RA14AY60AJ1NA used on the wide-cabinet 5 ton package, so line set sizing, pad requirements, and electrical sizing carry over. Only the indoor cabinet and its AHRI certificate differ. Heat kits, thermostats, and copper are ordered separately.

Condensing Unit & Air Handler Features

RA14AY60AJ1NA Outdoor Condensing Unit

  • 5 ton nominal capacity, 60,000 BTU, rated 13.8 SEER2 in this pairing
  • Engineered for low-GWP R-454B under the 2025 EPA 700 GWP limit
  • 7mm condenser copper coil reduces refrigerant requirements
  • Lighter, more compact cabinet than legacy large-diameter coil designs
  • PlusOne Triple Service Access with two-fastener removable corner
  • Patented one-box PlusOne Refrigerant Detection System
  • Automatic outdoor unit pause on excess refrigerant detection
  • Works with any 24V thermostat application
  • Curved louvered panels and corrosion-resistant composite base pan
  • 10-year conditional parts warranty with Rheem registration

RH2TY6021STANAJ Air Handler

  • 21-inch cabinet rated for 4.5 to 5 ton applications
  • Roughly 3.5 inches narrower than the standard 5 ton chassis
  • 3/4 HP constant torque ECM blower motor
  • Two-stage airflow for longer, quieter part-load cycles
  • 1.0 inch foil-faced insulation for reduced radiated noise
  • All-aluminum coil with internally grooved tubing
  • Factory thermal expansion valve matched to R-454B
  • 4-way convertible for upflow, downflow, and horizontal orientations
  • Field-installed heater kits with UL and cUL compliant breakers
  • Integrated A2L sensor and mitigation board, no field kit needed

Specifications & Manuals

Product documentation includes condenser and air handler technical specifications, submittal data, installation instructions, and warranty information to assist with equipment selection, permitting, installation, and service.

Frequently Asked Questions

Do I give up capacity by choosing the 21-inch cabinet?

No. The RH2TY6021STANAJ is rated for 4.5 to 5 ton applications and this pairing carries a full 60,000 BTU nominal capacity at 13.8 SEER2 under AHRI 216011746, the same rated efficiency as the wide-cabinet version.

What is the actual cabinet width I should plan for?

Rheem lists this chassis in the 21-inch class, with the published dimension at 21.5 inches. Add service and door clearance on top of that when measuring a closet opening, and confirm against the RH2TY submittal sheet before committing to the framing.

Why would a builder choose this over the 24.5-inch model?

Floor plan efficiency. In multi-family and townhouse construction, reclaiming three and a half inches of chase width across dozens of units adds up, and the narrower cabinet lets a 5 ton system fit chases originally detailed for 4 ton equipment.

Is the outdoor unit different from the wide-cabinet 5 ton system?

No. Both packages use the RA14AY60AJ1NA condenser. Pad size, line set sizing, and electrical requirements are identical; the difference is entirely on the indoor side and in the AHRI certificate number.

Can this air handler go in an attic between trusses?

The narrower footprint makes attic placement easier where truss spacing limits width, and the unit supports horizontal left and horizontal right orientations. Attic installs still require a secondary drain pan, a float switch, and code-compliant platform and walkway access.

What should I check on a condo retrofit before ordering?

Measure the closet opening and door width, confirm the supply plenum transition can be adapted, verify condensate routing and the available electrical service, and check any HOA rules on outdoor unit placement and sound. Our team can review the details at 813-885-7999.

Customer Review