3 Ton Bosch IDS Light 15 SEER2 R-454B Heat Pump Inverter Condenser, BOVB-36RTB-M15S
The 3 ton Bosch BOVB-36RTB-M15S is the mid-size condenser in the IDS Light inverter heat pump lineup and the most flexible to pair. It delivers 34,200 BTU/h nominal cooling and 34,600 BTU/h nominal heating with R-454B refrigerant. Bosch has AHRI-rated it with 3 ton indoor units and also with 2 ton air handlers. Paired with the 2 ton IDS Premium air handler, it reaches 18.0 SEER2, which suits homes that need extra outdoor capacity without oversizing the ductwork. Homeowners in medium-size houses and contractors handling R-410A changeouts get inverter comfort, precise EEV refrigerant control and heating down to 3°F outdoors. Compare it with other heat pump condensers in our catalog.
Is a 3 Ton Heat Pump the Right Size?
A 3 ton heat pump fits homes whose calculated load is about 34,000 BTU/h in both cooling and heating. That typically means a mid-size family home or a larger single-level ranch in a moderate climate. Because the inverter compressor slows down at part load, the BOVB-36RTB-M15S spends most of the season running below full capacity. This keeps temperatures steady and pulls moisture out of the air during long, mild cooling days.
In heating-dominated climates, size for the winter load as well as the summer load. Duct static pressure, attic insulation, glass area, infiltration and the coldest design temperature all matter. If your existing ducts only move enough air for 2 tons, Bosch's AHRI matchup with a 2 ton indoor unit can be the better fit. A load calculation will show which way to go.
Ideal for: Mid-size single-family homes, larger condos and ranch-style houses, and 3 ton R-410A system replacements that are moving to R-454B.
Need more capacity? Step up to the 5 Ton Bosch IDS Light Heat Pump Inverter Condenser, BOVB-60RTB-M15S, rated for 4 and 5 ton indoor matchups in larger homes.
Recommended heat pump applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, air leakage, window area and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Unit | BOVB-36RTB-M15S — 3 Ton IDS Light Heat Pump Inverter Condenser (Bosch Part No. 8733982682) |
|---|---|
| Indoor Unit | Sold separately — matched indoor options listed below |
| Application | Ducted Split-System Heat Pump, Heating & Cooling |
| Refrigerant | R-454B (A2L) — 5 lbs. 11 oz. spec-sheet charge |
| Compressor | Standard Inverter Compressor |
| Defrost | Demand Defrost Control |
| Electrical | 208/230V, Single Phase, 60 Hz — 25.8 MCA / 40 A Max Overcurrent Protection |
| Line Sizes | 3/8" Liquid / 3/4" Suction (5/8" optional) — up to 100 ft line length, 50 ft elevation |
| Dimensions / Weight | 28" x 28" x 24-15/16" — 129 lbs. net |
This listing is for the outdoor condenser only. The BOVB-36RTB-M15S has a two-row outdoor coil with 12.69 sq. ft. of face area, and Bosch lists more AHRI matchups for it than for any other IDS Light size. With IDS Premium air handlers, it rates 17.0 SEER2 on the BIVB-36RCB-M20X and 18.0 SEER2 on the BIVB-24RCB-M20X. With IDS Light air handlers, it rates 14.3 SEER2 on the BIVA-36RXB-M15X and 15.2 SEER2 on the BIVA-24RXB-M15X. Dual-fuel installers can use the Bosch BMAC3036BBTA 17.5" cased coil or the BMAC3036CBTA 21" cased coil, both AHRI-rated at 16.0 SEER2 with a Bosch BGH97 furnace.
Condenser Features & Matched Indoor Options
BOVB-36RTB-M15S Outdoor Inverter Condenser
- 34,200 BTU/h nominal cooling and 34,600 BTU/h nominal heating
- Two-row coil with 12.69 sq. ft. net face area and 17 fins per inch.
- Inverter compressor ramps capacity up and down with the home's load
- EEV expansion device on the outdoor unit
- Heating operation from 3°F to 86°F and cooling operation from 40°F to 120°F outdoors
- Demand Defrost Control based on coil temperature, ambient temperature, run time and high pressure
- DIP switch options for accelerated cooling/heating and adaptive capacity output
- Compressor crankcase heater and IPM/control board high temperature protection
- 1/3 HP condenser fan motor (2.0 FLA), 19 RLA compressor
- Sound rating of 60.4 dB(A) at minimum load and 76.0 dB(A) at full load
IDS Light & IDS Premium Indoor Pairings
- BIVB-24RCB-M20X IDS Premium: 24,000 BTU/h, 18.0 SEER2, 9 HSPF2
- BIVB-36RCB-M20X IDS Premium: 34,200 BTU/h, 17.0 SEER2, 9 HSPF2
- BIVA-24RXB-M15X IDS Light: 15.2 SEER2
- BIVA-36RXB-M15X IDS Light: 14.3 SEER2, 8 HSPF2
- BMAC3036 and BMAC4248 cased coils with a Bosch BGH97 furnace for dual-fuel heat
- Indoor unit must provide refrigerant leak detection for R-454B
- Conventional 24V thermostat wiring; supports 1- or 2-stage electric auxiliary heat
- Optional IDS Gateway accessory (8733982717) for Bosch EasyAir app access
- Set the unit on a level, sturdy condenser pad or wall mount
- Keep at least 12" of clearance on the control board access panel side
Specifications & Manuals
Product documentation includes technical specifications, AHRI matchup data, installation and operating instructions, a parts list, warranty terms and the Bosch product catalog to help with equipment selection, installation and service.
Frequently Asked Questions
Can the BOVB-36RTB-M15S be paired with a 2 ton air handler?
Yes. Bosch's AHRI table lists the BOVB-36RTB-M15S with both the BIVB-24RCB-M20X (18.0 SEER2) and the BIVA-24RXB-M15X (15.2 SEER2) 2 ton air handlers. That makes it an option when existing ductwork is sized for 2 tons.
What changes between the 3 ton BOVB-36RTB-M15S and the 2 ton BOVB-24RTB-M15S?
The 3 ton model adds about 10,000 BTU/h of nominal capacity, uses a two-row outdoor coil instead of one row and holds 5 lbs. 11 oz. of R-454B versus 4 lbs. 13 oz. It also needs a slightly larger 25.8 MCA / 40 A circuit. Cabinet dimensions are the same.
What refrigerant line set does the 3 ton model use?
The standard line set is 3/8" liquid and 3/4" suction, with 5/8" suction listed as an option. Total equivalent length can reach 100 ft with up to 50 ft of vertical separation. Browse copper line sets for your installation.
Can I control this heat pump from my phone?
Yes, with the optional Bosch IDS Gateway accessory (Part No. 8733982717) and the Bosch EasyAir app. Bosch notes that connectivity works only when the condenser is installed with an IDS Premium air handler, a BMXF modular blower or a BGH97 furnace.
What electrical circuit does the BOVB-36RTB-M15S require?
It runs on 208/230V, single phase, 60 Hz power with a 25.8 A minimum circuit ampacity and 40 A maximum overcurrent protection. Bosch calls for time-delay fuses or HACR-type breakers. Size the wire to the National Electrical Code, especially on long runs.
Can this condenser be used in a dual-fuel system with a gas furnace?
Yes. Bosch has AHRI-rated the BOVB-36RTB-M15S with several BMAC cased coils, including the BMAC3036ABTA, BBTA and CBTA and the BMAC4248BBTA and CBTA, installed on Bosch BGH97 gas furnaces. Those matchups are rated at 16.0 SEER2 and 9 HSPF2.
Bosch IDS Light Condenser Technical Specifications
Bosch IDS Light Condenser Installation Instructions
Bosch IDS Light Condenser Parts List
Bosch IDS Light Warranty