4 Ton Bosch IDS Light 14.3 SEER2 R-454B Heat Pump Inverter System, BOVB-60RTB-M15S, BIVA-48RXB-M15X
This 4 ton Bosch IDS Light system pairs the 5 ton BOVB-60RTB-M15S inverter condenser with the 4 ton BIVA-48RXB-M15X air handler. The inverter compressor modulates to match the smaller indoor coil, and Bosch certifies the pair under AHRI Reference No. 215225117 at 46,000 BTU/h cooling, 47,000 BTU/h heating, 14.3 SEER2 and 11 EER2. That 11 EER2 is the highest peak-load efficiency of any IDS Light matched system. Built around R-454B with a factory A2L sensor and TXV indoors, it suits larger homes that need more than 3 tons but not a full 5.
Is a 4 Ton Heat Pump System the Right Size?
The system is rated for about 46,000 BTU/h of cooling and 47,000 BTU/h of heating at 1,470 CFM of rated airflow. It typically fits larger single-family homes, two-story houses on one system or homes with high solar gain. Because a 5 ton condenser drives a 4 ton coil, the compressor has capacity in reserve and spends much of its time at reduced speed.
At this size, ductwork becomes a deciding factor. Return air capacity, trunk sizing and filter area all need to support nearly 1,500 CFM without high static pressure. Have a Manual J load calculation done, and inspect existing ducts, before you choose between this system and the 3 or 5 ton options.
Ideal for: Larger single-family and two-story homes, homes with high cooling loads and 4 ton heat pump replacements converting to R-454B.
Need more capacity? Step up to the 5 Ton Bosch IDS Light Heat Pump Inverter System, BOVB-60RTB-M15S, BIVA-60RXB-M15X for homes needing about 54,000 BTU/h of cooling.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, air leakage, window area and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | BOVB-60RTB-M15S — 5 Ton IDS Light Heat Pump Inverter Condenser |
|---|---|
| Indoor Air Handler | BIVA-48RXB-M15X — 4 Ton IDS Light Multi-Position Air Handler |
| Application | Ducted Split-System Heat Pump, Heating & Cooling |
| AHRI Rated Performance | 46,000 BTU/h Cooling / 47,000 BTU/h Heating — 14.3 SEER2, 11 EER2 (AHRI No. 215225117) |
| Refrigerant | R-454B (A2L) with Factory A2L Sensor in Air Handler |
| Compressor | Standard Inverter Compressor |
| Defrost | Demand Defrost Control |
| Electrical | 208-230V, Single Phase, 60 Hz Condensing Unit — 38.7 MCA / 60 A Max |
| Air Handler Electrical | 208-230V, Single Phase — 4.3 MCA / 15 A Max (without heat kit) |
| Line Set Size | 3/8" Liquid x 7/8" Suction (not included) |
This system includes the BOVB-60RTB-M15S inverter condenser and the BIVA-48RXB-M15X 4 ton air handler, which is Bosch's AHRI-listed way to build a 4 ton IDS Light system. The condenser's 18.25 sq. ft. outdoor coil works against a 5.99 sq. ft. indoor coil, which helps explain the strong 11 EER2 peak efficiency. The 4 ton cabinet accepts every Bosch EHK-B heat kit up to the 20 kW EHK-20B dual-circuit heat strip.
Condensing Unit & Air Handler Features
BOVB-60RTB-M15S Outdoor Condensing Unit
- 5 ton inverter condenser modulating to a 4 ton indoor load
- Large 18.25 sq. ft. two-row outdoor coil
- Outdoor EEV for accurate refrigerant control across the speed range
- Heating operation down to 3°F outdoors
- Demand Defrost Control based on coil temperature, ambient temperature and run time
- Compressor crankcase heater
- High/low pressure and compression ratio protection
- IPM and control board high temperature protection
- 29-1/8" x 29-1/8" x 33-3/16" cabinet, 181 lbs. net
- 7/8" suction connection, up to 100 ft line length
BIVA-48RXB-M15X Multi-Position Air Handler
- 2/5 HP PSC blower with three speed taps
- 5.99 sq. ft., 4-row all-aluminum evaporator coil
- Factory-installed A2L refrigerant sensor
- Factory-installed, non-adjustable R-454B TXV
- Upflow or horizontal right standard; converts to downflow or horizontal left
- Accepts Bosch EHK-05B through EHK-20B heat kits
- Cabinet sealed to 2% or less air leakage
- Integrated filter rack for a 20" x 22" filter
- Electrical entry through the top or either side
- 54-1/2" tall x 22" wide cabinet, 157 lbs. net
Specifications & Manuals
Product documentation includes condenser and air handler technical specifications, installation instructions, parts lists, warranty information and the Bosch product catalog to help with equipment selection, installation and service.
Frequently Asked Questions
Why does a 4 ton system use a 5 ton condenser?
The IDS Light outdoor lineup comes in 2, 3 and 5 ton sizes, with no 4 ton condenser. Bosch AHRI-certifies the 5 ton BOVB-60RTB-M15S with the 4 ton BIVA-48RXB-M15X. The inverter compressor modulates its output so the system delivers its rated 46,000 BTU/h of cooling.
How does the 4 ton system compare with the 3 ton IDS Light system?
This system adds roughly 12,000 BTU/h of cooling, raises rated airflow from 1,160 to 1,470 CFM and improves EER2 from 10 to 11. It uses larger cabinets indoors and out, a 7/8" suction line instead of 3/4", and the condenser needs a 60 A breaker instead of 40 A.
Can this system connect to the Bosch EasyAir app?
Not in this configuration. Bosch states that the condenser's optional IDS Gateway connectivity works only when it's installed with an IDS Premium air handler, a BMXF modular blower or a BGH97 furnace. The BIVA IDS Light air handler is not on that list.
What heat kit sizes can be added to the 4 ton system?
The BIVA-48RXB-M15X accepts Bosch EHK-05B (5 kW), EHK-08B (7.5 kW), EHK-10B (10 kW), EHK-15B (15 kW) and EHK-20B (20 kW) breakered kits. The 15 and 20 kW kits are dual-circuit and need two electrical supply circuits.
How much space do the two units need?
The condenser measures 29-1/8" x 29-1/8" x 33-3/16" tall. The air handler measures 24" deep x 22" wide x 54-1/2" tall and needs 25" of clearance in front for filter and coil service. Check the installation instructions for side clearances and R-454B minimum room area.
What warranty applies to the 4 ton IDS Light system?
Bosch's limited warranty covers the compressor and internal components for 10 years in one- and two-family homes. Registering within 90 days adds a 90-day labor allowance. Commercial installations carry 3 years on the compressor and 1 year on other components.
Bosch IDS Light Condenser Technical Specifications
Bosch IDS Light Condenser Installation Instructions
Bosch IDS Light Condenser Parts List
Bosch IDS Light Warranty
Bosch IDS Light Air Handler Technical Specifications
Bosch IDS Light Air Handler Installation Instructions
Bosch IDS Light Air Handler Parts List
Bosch Catalog