3 Ton Bosch IDS Light 15 SEER2 R-454B Multi-Position Air Handler, BIVA-36RXB-M15X
The Bosch BIVA-36RXB-M15X is a 3 ton, multi-position air handler that pairs with two IDS Light inverter heat pumps, which makes it one of the most adaptable indoor units in the series. Bosch has AHRI-rated it with the 3 ton BOVB-36RTB-M15S condenser and also with the 5 ton BOVB-60RTB-M15S. The 5 ton pairing reaches 14.6 SEER2 and 35,200 BTU/h of heating, which helps in colder climates where the heating load runs higher than the cooling load. The unit includes a factory-installed A2L leak sensor and R-454B TXV, a 1/3 HP three-speed PSC blower and an all-aluminum four-row coil, and it accepts electric heat kits up to 15 kW.
Is a 3 Ton Air Handler the Right Size?
This air handler is rated for 34,200 BTU/h of nominal cooling and 34,600 BTU/h of nominal heating. It fits mid-size homes whose calculated load falls near 3 tons. At high speed the blower moves up to 1,526 CFM at zero static pressure and still delivers more than 1,180 CFM at 0.5" w.c. That gives most 3 ton duct systems enough room to stay within Bosch's 300 to 450 CFM per ton requirement.
Pick the outdoor pairing based on your heating needs. Homes in mild climates usually match it with the BOVB-36RTB-M15S. Homes where winter heating drives the design may benefit from the BOVB-60RTB-M15S pairing and its higher heating output. A Manual J load calculation will show which pairing fits your home.
Ideal for: Mid-size single-family homes, larger condos, ranch-style houses and 3 ton heat pump replacements moving to R-454B.
Need more capacity? Step up to the 4 Ton Bosch IDS Light R-454B Air Handler, BIVA-48RXB-M15X for homes with a load near 46,000 BTU/h.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, static pressure, air leakage and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Indoor Unit | BIVA-36RXB-M15X — 3 Ton IDS Light Multi-Position Air Handler (Bosch Part No. 8733965420) |
|---|---|
| Matching Outdoor Unit | Sold separately — Bosch BOVB-36RTB-M15S or BOVB-60RTB-M15S IDS Light Inverter Heat Pump |
| Application | Split-System Heat Pump Air Handler — Upflow, Downflow, Horizontal Left or Right |
| Refrigerant | R-454B with Factory-Installed A2L Refrigerant Sensor |
| Metering Device | Factory-Installed R-454B TXV |
| Blower Motor | 1/3 HP PSC, 3 Selectable Speeds |
| Electrical | 208/230V, Single Phase, 60 Hz — 3.3 MCA / 15 A Max Overcurrent (without heat kit) |
| Line Connections | 3/8" Liquid / 3/4" Suction (sweat) |
| Dimensions / Weight | 21-5/8" D x 19-5/8" W x 46-1/2" H — 130 lbs. net |
This listing is for the air handler only. The outdoor heat pump, heat kit and filter are sold separately. With the BOVB-36RTB-M15S, the system is AHRI-rated at 34,200 BTU/h cooling, 34,600 BTU/h heating and 14.3 SEER2. With the BOVB-60RTB-M15S 5 ton condenser, it rises to 14.6 SEER2, 11 EER2 and 35,200 BTU/h heating. For backup heat, add the Bosch EHK-08B breakered heat strip or step up to the 15 kW EHK-15B dual-circuit heat strip.
Air Handler Features & Matched Heat Pump Options
BIVA-36RXB-M15X IDS Light Air Handler
- 34,200 BTU/h nominal cooling and 34,600 BTU/h nominal heating
- 1/3 HP three-speed PSC blower, up to 1,526 CFM at high speed
- Factory-installed A2L refrigerant leak sensor
- Factory-installed R-454B TXV metering device
- All-aluminum, 4-row evaporator coil for corrosion resistance
- Same compact 46-1/2" tall cabinet as the 2 ton model
- Cabinet sealed to 2% or less air leakage at 1.0" w.c.
- Dual front panels with slide-out blower and coil for easy service
- Primary and secondary condensate drain fittings
- Sound level of 69.7 dB(A) at high speed
Matched BOVB Heat Pumps & Accessories
- BOVB-36RTB-M15S 3 ton inverter heat pump: 14.3 SEER2
- BOVB-60RTB-M15S 5 ton inverter heat pump: 14.6 SEER2, 35,200 BTU/h heat
- Bosch EHK-05B, EHK-08B (7.5 kW), EHK-10B and EHK-15B heat kits
- EHK-15B uses two heater elements on two separate circuits
- DIP switch speed tap on the control board for airflow setup
- Compatible with most standard 24 VAC heat pump thermostats
- 18" x 20" filter in an integrated, tool-less filter rack
- Multiple high- and low-voltage electrical entry points
- Run 3/8" x 3/4" copper line sets to the outdoor unit
- AHRI and ETL listed
Specifications & Manuals
Product documentation includes technical specifications, airflow and heater kit data, installation instructions, a spare parts list, warranty terms and the Bosch product catalog to help with equipment selection, installation and service.
Frequently Asked Questions
Why would I pair the BIVA-36RXB-M15X with a 5 ton BOVB-60RTB-M15S?
Bosch rates this combination at 14.6 SEER2 with 35,200 BTU/h of heating, compared with 34,600 BTU/h using the 3 ton BOVB-36RTB-M15S. That extra outdoor capacity can help homes with a heavier heating load while keeping a 3 ton indoor unit and ductwork.
What is different between the BIVA-36RXB-M15X and the 2 ton BIVA-24RXB-M15X?
The cabinets are the same size, but the 3 ton unit has a stronger 1/3 HP blower that moves up to 1,526 CFM versus 1,134 CFM. It also accepts heat kits up to 15 kW. Its minimum circuit ampacity without a heat kit is 3.3 A, compared with 1.8 A on the 2 ton.
Can the BIVA-36RXB-M15X be converted to downflow or horizontal left?
Yes. It ships for upflow or horizontal right. For horizontal left or downflow, the installer repositions the coil and the A2L refrigerant sensor following the steps in Bosch's installation instructions.
What circuit does the 3 ton air handler need without a heat kit?
Without electric heat, it needs a 3.3 A minimum circuit ampacity and 15 A maximum overcurrent protection at 208/230V single phase. Adding a heat kit raises those numbers. For example, the EHK-10B requires 54.7 MCA at 240V.
How is the blower speed set on this air handler?
The PSC motor has low, medium and high speed taps, selected with a DIP switch on the control board. Installers choose the tap that delivers the correct CFM at the system's measured static pressure, using Bosch's airflow performance table.
How loud is the BIVA-36RXB-M15X?
Bosch lists a sound level of 69.7 dB(A) at high blower speed. Lower speed taps, well-sized return ducts and a properly balanced duct system all help reduce airflow noise inside the home.
Bosch IDS Light Air Handler Technical Specifications
Bosch IDS Light Air Handler Installation Instructions
Bosch IDS Light Air Handler Parts List
Bosch Catalog