2 Ton Rheem 14.3 SEER2 R-454B Two-Stage Heat Pump Apartment/Condo System
Pairing the Rheem RP14AY24AJ2NA two-stage heat pump with the RF2TY2421STANSJ apartment/condo air handler, this 2 ton (24,000 BTU) R-454B system is AHRI-certified at 14.3 SEER2 (AHRI #215772190). The two-stage scroll compressor runs on low stage most of the time for steadier temperatures and better humidity control, then ramps to high stage on the hottest and coldest days. Inside, the 36" tall RF2TY fits standard apartment mechanical closets with a front or bottom return. It is a practical heat pump upgrade for one- and two-bedroom condos and apartments that want quieter, more even comfort than a single-stage system.
Is a 2 Ton Two-Stage Heat Pump the Right Size?
A 2 ton heat pump commonly serves homes of about 900 to 1,200 square feet, covering many one-bedroom-plus-den and two-bedroom floor plans. Because a heat pump also provides heat, the load calculation should look at winter as well as summer.
Two-stage operation is more forgiving than single-stage when a home falls between sizes, because low stage handles mild days without short cycling. Even so, unit position in the building, window exposure, and climate should drive the final choice. Interior units often need less capacity than top-floor or corner units with more exterior surface.
Ideal for: One- and two-bedroom condos and apartments, rental units being upgraded from older heat pumps, townhome-style units with closet air handlers, and owners who want two-stage comfort at a budget-friendly price.
Need more capacity? Step up to the 2.5 Ton Rheem RP14AY30AJ2NA & RF2TY3624STANSJ Heat Pump System for larger units requiring additional heating and cooling capacity.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, windows, sun exposure, ceiling height, climate, occupancy, and ductwork. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | RP14AY24AJ2NA — 2 Ton Endeavor Line Classic Series Two-Stage R-454B Heat Pump |
|---|---|
| Indoor Air Handler | RF2TY2421STANSJ Apartment/Condo Front-Return Air Handler (21-1/2" Cabinet) |
| Application | Split System Heat Pump, Cooling & Heating — 14.3 SEER2, AHRI #215772190 |
| Refrigerant | R-454B |
| Compressor | Two-Stage Scroll Compressor |
| Blower Motor | 1/3 HP Constant Torque ECM, Two-Stage Airflow |
| Electrical | 208-230V, Single Phase, 60 Hz Condensing Unit |
| Air Handler Electrical | 208-240V, Single Phase, 60 Hz |
The RP14AY24AJ2NA uses the same compact 25" tall, 29-3/4" square cabinet as the 1.5 ton model, with a 1/6 HP fan moving 2,620 CFM and an 83 oz R-454B charge. The RF2TY2421STANSJ steps up to its 800 CFM high-stage airflow for this size; the RF2TY2421STANSJB05417 5 kW air handler is one of four heat options. Both units connect at 3/4" suction and 3/8" liquid, so a 25 ft 3/4" x 3/8" copper line set suits most apartment runs, and the Honeywell Pro 8000 Wi-Fi thermostat supports multi-stage heat pump control.
Condensing Unit & Air Handler Features
RP14AY24AJ2NA Outdoor Heat Pump
- 2 ton two-stage scroll heat pump on R-454B
- Two compressor stages for precise temperature and lower humidity
- Inverted reversing valve reduces joint stress
- 83 oz factory refrigerant charge
- 20" three-blade, 1/6 HP condenser fan at 1,075 RPM
- 16 MCA with 25 amp maximum HACR breaker or fuse
- Composite base pan and powder-coat paint
- External gauge ports and service trays
- Low-ambient capable with RXAD-A08 kit
- Conditional 10-year parts limited warranty, registration required
RF2TY2421STANSJ Apartment/Condo Air Handler
- 800 CFM high-stage / 600 CFM low-stage airflow
- 36" H x 21-1/2" W x 17" D upflow cabinet
- Field-convertible front or bottom return
- Constant-torque ECM blower, 1/3 HP
- TXV metering and aluminum indoor coil
- Factory A2L refrigerant sensor and mitigation board
- Front refrigerant and drain connections
- Fresh air knockouts and supply/return duct flanges
- Concentric knockouts for up to 1-1/2" conduit
- No-heat, 5, 8, or 10 kW configurations offered
Specifications & Manuals
Product documentation includes RP14AY heat pump specifications, installation instructions, and brochure, RF2TY air handler specifications and installation instructions, and Rheem warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
How many square feet does the 2 ton RP14AY24AJ2NA heat pump system cover?
As a general guideline, about 900 to 1,200 square feet. Unit position, windows, and climate change the actual load, so a heating and cooling load calculation is recommended.
What does two-stage operation do for an apartment heat pump?
The RP14AY24AJ2NA has a two-stage scroll compressor with high and low speeds. Low stage handles most conditions for steadier temperatures and better dehumidification, while high stage covers peak heating and cooling demand.
How does this system compare with the 2 ton Rheem short apartment heat pump?
Both use the RP14AY24AJ2NA outdoors. This system uses the 36" tall, upflow-only RF2TY2421STANSJ with front or bottom return, while the 2 ton short apartment system with the RB2TY2417STANMJB uses a 35" multi-position air handler and is rated 14.8 SEER2.
What thermostat does a two-stage RP14AY heat pump need?
Use a heat pump thermostat that supports the system's stages and auxiliary heat. Rheem's PlusOne Refrigerant Detection System is compatible with any 24V thermostat application.
What breaker size does the RP14AY24AJ2NA require?
Rheem lists a 16 amp minimum circuit ampacity and a 25 amp maximum HACR breaker or fuse at 208/230V single phase for the 2 ton RP14AY. The air handler is wired separately based on the heat strip selected.
Who typically chooses the 2 ton Rheem apartment heat pump?
Landlords upgrading rental units, condo owners replacing older heat pumps, and contractors who want an R-454B two-stage system for standard apartment closets. Learn more in our refrigerant transition guide, or compare the 2 ton RA14AY air conditioner version.
RP14AY Technical Specifications
RP14AY Installation Instructions
RP14AY Brochure
RF2TY Technical Specifications
RF2TY Installation Instructions
Rheem Warranty Certificate