2.5 Ton Rheem 14.3 SEER2 R-454B Two-Stage Heat Pump Apartment/Condo System
This AHRI-matched system pairs the Rheem Endeavor Line Classic Series RP14AY30AJ2NA two-stage heat pump with the RF2TY3624STANSJ apartment/condo air handler for 2.5 tons (30,000 BTU) of heating and cooling at 14.3 SEER2 (AHRI #215772208). It fills the gap between 2 and 3 tons for condos that have outgrown a 2 ton unit but would be oversized at 3. Indoors, the 36" tall RF2TY3624 uses a 1/2 HP constant-torque ECM blower that is set on its 2.5 ton speed taps for this pairing. Outdoors, the RP14AY30AJ2NA has a 27" tall cabinet, a 24" fan, and a 99 oz R-454B charge. It is a good fit for roomy two-bedroom apartments and smaller three-bedroom condos with a standard mechanical closet.
Is a 2.5 Ton Condo Heat Pump the Right Size?
As a general guideline, 2.5 tons serves homes of about 1,200 to 1,500 square feet. That covers many larger two-bedroom units and compact three-bedroom floor plans. Because this heat pump handles winter heating as well as summer cooling, base the final size on a load calculation for both seasons.
The half-ton step matters in a condo. Too little capacity leaves rooms warm on peak afternoons, and too much leads to short cycles and clammy air. The two-stage compressor adds flexibility by running on low stage through most of the year. The air handler's 2.5 ton taps keep airflow inside Rheem's recommended 894 to 1,145 CFM range. Check that the existing ducts and return can carry that airflow before the replacement.
Ideal for: Spacious two-bedroom condos, smaller three-bedroom apartments, units that run short on capacity with a 2 ton system, and replacement of 2.5 ton apartment-style closet heat pumps.
Need more capacity? Step up to the 3 Ton Rheem RP14AY36AJ2NA & RF2TY3624STANSJ Heat Pump System. It uses the same air handler cabinet and suits larger units that need more heating and cooling capacity.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, windows, sun exposure, ceiling height, climate, occupancy, and ductwork. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | RP14AY30AJ2NA — 2.5 Ton Endeavor Line Classic Series Two-Stage R-454B Heat Pump |
|---|---|
| Indoor Air Handler | RF2TY3624STANSJ Apartment/Condo Front-Return Air Handler (24-1/2" Cabinet) |
| Application | Split System Heat Pump, Cooling & Heating — 14.3 SEER2, AHRI #215772208 |
| Refrigerant | R-454B |
| Compressor | Two-Stage Scroll Compressor |
| Blower Motor | 1/2 HP Constant Torque ECM, 5-Speed with Two-Stage Airflow |
| Electrical | 208-230V, Single Phase, 60 Hz Condensing Unit |
| Air Handler Electrical | 208-240V, Single Phase, 60 Hz |
The RP14AY30AJ2NA heat pump is 27" tall on a 33-3/4" square base and weighs 189 lb operating. A 36" x 36" heavy-duty condenser pad gives it a full-footprint base. The RF2TY3624STANSJ measures 24-1/2" W x 36" H x 21" D and takes a 20" x 25" x 1" filter. For built-in backup heat, the RF2TY3624STANSJB08417 8 kW air handler is a common middle option. Both units connect at 3/4" suction and 3/8" liquid, which suits an insulated 25 ft 3/4" x 3/8" line set. The Honeywell T6 Pro 3H/2C thermostat is a programmable control option.
Condensing Unit & Air Handler Features
RP14AY30AJ2NA Outdoor Heat Pump
- 2.5 ton (30,000 BTU) two-stage scroll heat pump on R-454B
- 14.4 sq ft outdoor coil with 7mm (0.276") tubing
- 24" three-blade fan, 1/5 HP at 850 RPM, 3,391 CFM
- 99 oz R-454B charge, good for 15 ft of line set
- 20 amp MCA, 30 amp maximum HACR breaker or fuse
- 27" H x 33-3/4" W x 33-3/4" L, 189 lb operating weight
- 72 dBA standard sound rating
- PlusOne Expanded Valve Space with 27 sq in working area
- 15" wide corner service access and individual louver panels
- Accessory options include the RXAD-A08 low ambient control and SK-A1 hard start kit
RF2TY3624STANSJ Apartment/Condo Air Handler
- Field-set to speed taps 2 and 3 for 2.5 ton operation
- Rheem-recommended 894 to 1,145 CFM airflow range at 2.5 tons
- Continuous fan runs at about half of high-stage airflow
- 1/2 HP five-speed constant-torque ECM, 10x8 blower
- 24-1/2" W x 36" H x 21" D steel cabinet
- Front return standard, field-convertible to bottom return
- Thermal expansion valve and aluminum fin/grooved-tube coil
- Integrated A2L sensor and mitigation board
- 1" foil-faced cabinet insulation for quieter operation
- Offered in no-heat, 5, 8, and 10 kW configurations
Specifications & Manuals
Product documentation includes RP14AY heat pump specifications, installation instructions, and brochure, RF2TY air handler specifications and installation instructions, and Rheem warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
Does the RF2TY3624STANSJ need its speed taps changed for a 2.5 ton heat pump?
Yes. Rheem ships every RF2TY air handler on speed taps 4 and 5, which are for the higher tonnage. With the 2.5 ton RP14AY30AJ2NA, the installer moves the blower to speed taps 2 (low static) and 3 (high static) as directed in the RF2TY specifications.
Roughly how many square feet can a 2.5 ton RP14AY30AJ2NA system handle?
About 1,200 to 1,500 square feet is a common guideline. Exterior walls, glass, insulation, and your winter design temperature all shift the real number. A load calculation is the reliable way to choose between 2, 2.5, and 3 tons.
Why does a 2.5 ton system use the larger 24-1/2" RF2TY3624 cabinet?
Rheem builds the RF2TY in two cabinets. The RF2TY24 covers 1.5 and 2 tons, and the RF2TY36 covers 2.5 and 3 tons. The 2.5 ton system uses the larger cabinet with its 1/2 HP motor and 10x8 blower, so plan for a closet that fits a 24-1/2" W x 21" D unit.
How does the RP14AY30AJ2NA outdoor unit differ from the 2 ton RP14AY24AJ2NA?
The 2.5 ton unit is larger: 27" tall on a 33-3/4" base instead of 25" on a 29-3/4" base. It has a 24" fan instead of a 20" fan, carries 99 oz of R-454B instead of 83 oz, and calls for a 30 amp maximum breaker instead of 25 amps. Both are two-stage and use 3/4" suction lines.
Is there a shorter, multi-position version of this 2.5 ton apartment heat pump?
Yes. The 2.5 ton Rheem short apartment heat pump with the RB2TY3621STANMJB uses the same RP14AY30AJ2NA outdoors with a multi-position air handler. The RF2TY3624STANSJ in this system installs in upflow only.
Can I get this 2.5 ton RF2TY setup as a straight air conditioner?
Yes. The 2.5 ton Rheem RA14AY30AJ1NA air conditioner system pairs the same RF2TY3624STANSJ air handler with a cooling-only condenser and uses electric heat strips for heating.
RP14AY Technical Specifications
RP14AY Installation Instructions
RP14AY Brochure
RF2TY Technical Specifications
RF2TY Installation Instructions
Rheem Warranty Certificate