2 Ton Rheem 15.2 SEER2 R454B Central Wall Mount Apartment/Condo Type System RA14AY24BJ1NA, RF2TY2421STANSJ
This 2 ton Rheem Endeavor® Line Classic® system pairs the second-design RA14AY24BJ1NA condenser with the RF2TY2421STANSJ wall mount apartment/condo air handler, AHRI certified at 15.2 SEER2 (#216375622). The RF2TY's constant torque motor and two-stage airflow raise efficiency above the PSC-based RF1PY match. It runs on low-GWP R-454B with Rheem's PlusOne® Refrigerant Detection System™. It's available with no heat or factory-installed 5, 8 or 10 kW breakered heat.
Is a 2 Ton Air Conditioning System the Right Size?
Two tons (24,000 BTU/h) is common in 1- and 2-bedroom apartments and condos around 900–1,200 sq. ft. as a general reference.
Corner units, top floors and large sliding doors raise the load. A Manual J load calculation is the best way to confirm 2 tons before replacing an existing wall mount system.
Ideal for: 1- and 2-bedroom apartments, condos and townhomes with a wall mount air handler closet.
Need more capacity? Step up to the 2.5 Ton Rheem 15.2 SEER2 R454B Central Wall Mount Apartment/Condo Type System RA14AY30AJ1NA, RF2TY3624STANSJ for a larger load.
Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | RA14AY24BJ1NA — 2 Ton Rheem Classic R454B Air Conditioner (B Design) |
|---|---|
| Indoor Air Handler | RF2TY2421STANSJ Wall Mount Apartment/Condo Two-Stage Air Handler (21.5" W x 36" H) |
| Application | Cooling-Only Wall Mount Apartment/Condo Split System (Factory Electric Heat Optional) |
| Refrigerant | R-454B (Low-GWP A2L Refrigerant) |
| Compressor | Single-Stage Scroll Compressor |
| Metering Device | Factory-Installed Expansion Valve on Indoor Coil (TXV) |
| Electrical | 208/230V, Single Phase, 60 Hz Condensing Unit — See Rating Plate (B Design) |
| Air Handler Electrical | 208/240V, Single Phase — 3 MCA / 15A Max (No Heat); Varies with Factory Heater |
The RA14AY24BJ1NA condenser is the second design of Rheem's 2 ton RA14AY; check its rating plate for exact electrical data. The RF2TY2421STANSJ air handler measures 21.5" wide, 36" tall and 17" deep, weighs 95 lbs and uses a 20" x 20" x 1" framed filter. Complete the install with compatible thermostats and copper line sets and fittings.
Condensing Unit & Air Handler Features
RA14AY24BJ1NA Outdoor Condensing Unit
- 24,000 BTU/h nominal cooling capacity
- Single-stage scroll compressor
- 7 mm copper tube condenser coil uses less refrigerant
- 3/8" liquid and 3/4" suction front-seating service valves
- PlusOne® Expanded Valve Space and Triple Service Access
- Composite base pan, powder-coated paint and rust-resistant screws
- Field-installed filter drier and external gauge ports
- 10-year conditional parts limited warranty (registration required)
RF2TY2421STANSJ Wall Mount Two-Stage Air Handler
- Compact 36" tall wall mount cabinet for apartment and condo closets
- 1/3 HP five-speed constant torque (ECM) motor with two-stage airflow
- PlusOne® Refrigerant Detection System™ with factory-installed A2L sensor
- Front or bottom return, vertical upflow installation
- Aluminum fins bonded to internally grooved aluminum tubing
- 1.0" foil-faced cabinet insulation for quieter operation
- Cabinet air leakage under 2% at 1" H₂O (ASHRAE 193)
- Continuous fan tap runs at 50% of the cooling airflow
- Durable framed cleanable 20" x 20" x 1" filter, 600/800 CFM nominal
- Factory-installed breakered heater options of none, 5, 8 or 10 kW
Specifications & Manuals
Documentation includes RA14AY electrical, sound, dimensional and line-size data, condenser installation instructions, the RA14AY brochure, RF2TY dimensions, airflow and heater tables, wall mount air handler installation instructions and the Rheem limited warranty.
Frequently Asked Questions
Why is this 2 ton wall mount rated 15.2 SEER2 while the RF1PY version is 14.3?
The RF2TY's constant torque motor and two-stage airflow use less fan energy than the RF1PY's PSC motor. The same condenser with the RF1PY2421 is AHRI rated 14.3 SEER2; see the RA14AY24BJ1NA, RF1PY2421STANSJ system.
Which speed taps does the RF2TY2421 use for 2 tons?
Rheem ships the RF2TY on speed taps 4 (low static) and 5 (high static), which are the 2 ton settings. No tap change is needed for this match.
Can the RF2TY2421STANSJ use a bottom return?
Yes. Rheem's RF2TY can be set up for a front or bottom return, but it's built for vertical upflow installation only.
Is the RF2TY filter washable?
Rheem supplies the RF2TY with a durable framed, cleanable 20" x 20" x 1" filter for the 21" cabinet. Clean or replace it regularly.
What circuit does the RF2TY2421 need with the 10 kW heater?
Rheem lists a 46/53 amp minimum circuit ampacity and 50/60 amp maximum circuit protection at 208/240V for the RF2TY24 with 10 kW.
Where do I find electrical data for the RA14AY24BJ1NA?
Use the condenser's rating plate. The linked RA14AY spec sheet covers the first-design RA14AY24A, and the B design's electrical values may differ.


RA14AY Technical Specifications
RA14AY Installation Instructions
RA14AY Brochure
RF2TY Technical Specifications
RF2TY Installation Instructions