decor decor

Summary

Product #180062: $3,345.00
  • Air Handler Heat Strip Option:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 41914 / 2 Ton Rheem R454B Single Stage Condenser RA14AY24BJ1NA (179282) -- 1
3345
$3,345.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
RA14AY24BJ1NA, RF2TY2421STANSJ | Higher-Efficiency 2 Ton Wall Mount Upgrade with an ECM Two-Stage Blower

2 Ton Rheem 15.2 SEER2 R454B Central Wall Mount Apartment/Condo Type System RA14AY24BJ1NA, RF2TY2421STANSJ

· SKU 180062 · AHRI 216375622 · Split System
SEER2
15.2
Capacity
24,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $4,350.00

Sale price:

$3,345.00
You save $1,005.00!
  • SKU: 180062
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    2
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    21"
  • Manufacturer Warranty:
    10 Years
  • 2 Ton Rheem R454B Wall Mount Apartment/Condo Type ECM Motor Air Handler RF2TY2421STANSJN00417
  • 2 Ton Rheem R454B Wall Mount Apartment/Condo Type ECM Motor Air Handler RF2TY2421STANSJB05417
  • 2 Ton Rheem R454B Wall Mount Apartment/Condo Type ECM Motor Air Handler RF2TY2421STANSJB08417
  • 2 Ton Rheem R454B Wall Mount Apartment/Condo Type ECM Motor Air Handler RF2TY2421STANSJB10417
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2 Ton Rheem 14.3 SEER2 R454B Single Stage Condenser RA14AY24BJ1NA
Adding to cart… The item has been added

2 Ton Rheem 15.2 SEER2 R454B Central Wall Mount Apartment/Condo Type System RA14AY24BJ1NA, RF2TY2421STANSJ

This 2 ton Rheem Endeavor® Line Classic® system pairs the second-design RA14AY24BJ1NA condenser with the RF2TY2421STANSJ wall mount apartment/condo air handler, AHRI certified at 15.2 SEER2 (#216375622). The RF2TY's constant torque motor and two-stage airflow raise efficiency above the PSC-based RF1PY match. It runs on low-GWP R-454B with Rheem's PlusOne® Refrigerant Detection System™. It's available with no heat or factory-installed 5, 8 or 10 kW breakered heat.

Is a 2 Ton Air Conditioning System the Right Size?

Two tons (24,000 BTU/h) is common in 1- and 2-bedroom apartments and condos around 900–1,200 sq. ft. as a general reference.

Corner units, top floors and large sliding doors raise the load. A Manual J load calculation is the best way to confirm 2 tons before replacing an existing wall mount system.

Ideal for: 1- and 2-bedroom apartments, condos and townhomes with a wall mount air handler closet.

Need more capacity? Step up to the 2.5 Ton Rheem 15.2 SEER2 R454B Central Wall Mount Apartment/Condo Type System RA14AY30AJ1NA, RF2TY3624STANSJ for a larger load.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit RA14AY24BJ1NA — 2 Ton Rheem Classic R454B Air Conditioner (B Design)
Indoor Air Handler RF2TY2421STANSJ Wall Mount Apartment/Condo Two-Stage Air Handler (21.5" W x 36" H)
Application Cooling-Only Wall Mount Apartment/Condo Split System (Factory Electric Heat Optional)
Refrigerant R-454B (Low-GWP A2L Refrigerant)
Compressor Single-Stage Scroll Compressor
Metering Device Factory-Installed Expansion Valve on Indoor Coil (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit — See Rating Plate (B Design)
Air Handler Electrical 208/240V, Single Phase — 3 MCA / 15A Max (No Heat); Varies with Factory Heater

The RA14AY24BJ1NA condenser is the second design of Rheem's 2 ton RA14AY; check its rating plate for exact electrical data. The RF2TY2421STANSJ air handler measures 21.5" wide, 36" tall and 17" deep, weighs 95 lbs and uses a 20" x 20" x 1" framed filter. Complete the install with compatible thermostats and copper line sets and fittings.

Condensing Unit & Air Handler Features

RA14AY24BJ1NA Outdoor Condensing Unit

  • 24,000 BTU/h nominal cooling capacity
  • Single-stage scroll compressor
  • 7 mm copper tube condenser coil uses less refrigerant
  • 3/8" liquid and 3/4" suction front-seating service valves
  • PlusOne® Expanded Valve Space and Triple Service Access
  • Composite base pan, powder-coated paint and rust-resistant screws
  • Field-installed filter drier and external gauge ports
  • 10-year conditional parts limited warranty (registration required)

RF2TY2421STANSJ Wall Mount Two-Stage Air Handler

  • Compact 36" tall wall mount cabinet for apartment and condo closets
  • 1/3 HP five-speed constant torque (ECM) motor with two-stage airflow
  • PlusOne® Refrigerant Detection System™ with factory-installed A2L sensor
  • Front or bottom return, vertical upflow installation
  • Aluminum fins bonded to internally grooved aluminum tubing
  • 1.0" foil-faced cabinet insulation for quieter operation
  • Cabinet air leakage under 2% at 1" H₂O (ASHRAE 193)
  • Continuous fan tap runs at 50% of the cooling airflow
  • Durable framed cleanable 20" x 20" x 1" filter, 600/800 CFM nominal
  • Factory-installed breakered heater options of none, 5, 8 or 10 kW

Specifications & Manuals

Documentation includes RA14AY electrical, sound, dimensional and line-size data, condenser installation instructions, the RA14AY brochure, RF2TY dimensions, airflow and heater tables, wall mount air handler installation instructions and the Rheem limited warranty.

Frequently Asked Questions

Why is this 2 ton wall mount rated 15.2 SEER2 while the RF1PY version is 14.3?

The RF2TY's constant torque motor and two-stage airflow use less fan energy than the RF1PY's PSC motor. The same condenser with the RF1PY2421 is AHRI rated 14.3 SEER2; see the RA14AY24BJ1NA, RF1PY2421STANSJ system.

Which speed taps does the RF2TY2421 use for 2 tons?

Rheem ships the RF2TY on speed taps 4 (low static) and 5 (high static), which are the 2 ton settings. No tap change is needed for this match.

Can the RF2TY2421STANSJ use a bottom return?

Yes. Rheem's RF2TY can be set up for a front or bottom return, but it's built for vertical upflow installation only.

Is the RF2TY filter washable?

Rheem supplies the RF2TY with a durable framed, cleanable 20" x 20" x 1" filter for the 21" cabinet. Clean or replace it regularly.

What circuit does the RF2TY2421 need with the 10 kW heater?

Rheem lists a 46/53 amp minimum circuit ampacity and 50/60 amp maximum circuit protection at 208/240V for the RF2TY24 with 10 kW.

Where do I find electrical data for the RA14AY24BJ1NA?

Use the condenser's rating plate. The linked RA14AY spec sheet covers the first-design RA14AY24A, and the B design's electrical values may differ.


 