1 To 5 ton Vertical Cased Coil

Vertical cased coils are designed for upflow or downflow applications, sitting neatly on top of your furnace or inside a vertical air handler. Their insulated cabinets improve efficiency and reduce condensation, while factory drain pans manage moisture reliably. Service-friendly panels help pros access the coil, TXV, and line connections for quick commissioning and maintenance.

Whether you are a licensed contractor, DIY-capable homeowner, property manager, or running light commercial spaces, these coils solve common needs: replacing a leaking or failed coil, matching the indoor coil to an existing condenser and furnace, and improving cooling performance and dehumidification. Select the nominal tonnage to match your outdoor unit-1 to 5 tons covers roughly 12,000 to 60,000 BTU. For best results and SEER2 performance, use AHRI-matched combinations so the system’s efficiency rating is preserved.

Most models are optimized for modern refrigerants such as R-410A, and select options may support newer blends like R-454B when paired with the correct metering device. Choose the right TXV or piston/orifice kit to match your condenser and ensure stable capacity, superheat, and subcooling. Planning a heat pump? Verify the coil and TXV are heat-pump rated. Always confirm cabinet width, height, and depth to fit your furnace or air handler opening and plenum.

Professional installation is required to protect warranty and ensure safe, code-compliant operation. A licensed technician will braze with nitrogen, evacuate to deep vacuum, pressure test, replace filter-driers, and charge by manufacturer specs for peak comfort and reliability.

Frequently Asked Questions

  • How do I size a vertical cased coil to match my condenser tonnage?

    Match the coil’s nominal tonnage to the outdoor unit. Some AHRI matches allow a slightly larger coil for efficiency, but never undersize. Follow the approved match.

  • Will these coils work with R-410A or newer refrigerants like R-454B?

    Most are R-410A ready. Select models and correct TXVs can support newer A2L refrigerants like R-454B. Confirm coil rating and metering device before installation.

  • What is the difference between vertical cased and horizontal cased coils?

    Vertical cased coils are for upflow/downflow cabinets and include vertical drain pan geometry. Horizontal cased coils are built for side-to-side airflow with multi-position drains.

  • Do I need a TXV or is a piston/orifice included with the coil?

    Many ship with a piston; a model-specific TXV may be required for SEER2 performance or heat pumps. Verify the correct metering device for your condenser.

  • Can I use this coil with a heat pump as well as an AC?

    Yes, if the coil and metering device are heat-pump rated. Ensure an AHRI match and proper check valves or heat pump TXV as specified by the manufacturer.

  • What cabinet dimensions should I check to ensure the coil fits my furnace/air handler?

    Measure cabinet width, height, and depth, the supply opening, and plenum connections. Confirm service clearance and drain orientation for proper installation.

  • Is professional installation required to maintain warranty on a cased coil?

    Yes. Most manufacturers require licensed installation, proper brazing with nitrogen, evacuation, and documented startup to keep the warranty valid.

  • How do I match coil SEER2 ratings with my outdoor unit?

    The coil itself doesn’t have a SEER2 rating; the system rating comes from the matched outdoor unit and furnace/air handler. Use AHRI-listed combinations.

  • Do these coils include a drain pan and insulation?

    Vertical cased coils include an insulated cabinet and corrosion-resistant drain pan. Review product details for materials and multi-position drain options.

  • What else should be replaced when swapping a coil?

    Replace the filter-drier, verify or install the correct TXV/piston, pressure test, evacuate, and assess the line set for flushing or replacement if contaminated.