5 Ton Bosch IDS Light 14.3 SEER2 R-454B Heat Pump Inverter System, BOVB-60RTB-M15S, BIVA-60RXB-M15X
At the top of the IDS Light range, this 5 ton system pairs the BOVB-60RTB-M15S inverter heat pump with the BIVA-60RXB-M15X, the only IDS Light air handler with a five-row coil. Certified under AHRI Reference No. 215225118, it delivers 54,000 BTU/h of cooling and 56,000 BTU/h of heating at 14.3 SEER2, with 1,650 CFM of rated airflow, the most in the series. R-454B refrigerant, a factory A2L leak sensor and TXV, and support for up to 20 kW of backup heat make it a complete matched solution for large homes and high-load new construction.
Is a 5 Ton Heat Pump System the Right Size?
This system is built for homes with a calculated load around 54,000 to 56,000 BTU/h. That's typically a large single-family or two-story home, a home in a hot or cold climate with heavy design loads, or new construction with open floor plans and high ceilings. Its heating capacity exceeds its cooling capacity, which helps in regions where winter load drives sizing.
A 5 ton system demands a duct system that can move about 1,650 CFM quietly. Many older homes have returns and trunks sized for less, which leads to high static pressure, noise and lost capacity. A Manual J load calculation and a duct evaluation will confirm whether this system or the 4 ton IDS Light system is the better fit.
Ideal for: Large single-family homes, two-story homes on one system, high-load new construction and 5 ton heat pump replacements upgrading to R-454B.
Need less capacity? Consider the 4 Ton Bosch IDS Light Heat Pump Inverter System, BOVB-60RTB-M15S, BIVA-48RXB-M15X, which uses the same condenser with a 4 ton air handler.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, air leakage, window area and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | BOVB-60RTB-M15S — 5 Ton IDS Light Heat Pump Inverter Condenser |
|---|---|
| Indoor Air Handler | BIVA-60RXB-M15X — 5 Ton IDS Light Multi-Position Air Handler |
| Application | Ducted Split-System Heat Pump, Heating & Cooling |
| AHRI Rated Performance | 54,000 BTU/h Cooling / 56,000 BTU/h Heating — 14.3 SEER2, 10 EER2 (AHRI No. 215225118) |
| Refrigerant | R-454B (A2L) with Factory A2L Sensor in Air Handler |
| Compressor | Standard Inverter Compressor |
| Defrost | Demand Defrost Control |
| Electrical | 208-230V, Single Phase, 60 Hz Condensing Unit — 38.7 MCA / 60 A Max |
| Air Handler Electrical | 208-230V, Single Phase — 5.0 MCA / 15 A Max (without heat kit) |
| Line Set Size | 3/8" Liquid x 7/8" Suction (not included) |
The package combines the BOVB-60RTB-M15S 5 ton condenser with the BIVA-60RXB-M15X 5 ton air handler, which has the series' only five-row coil and its strongest 1/2 HP blower. Together they move the most air and deliver the most heat of any IDS Light pairing. For cold snaps, add the 15 kW EHK-15B or the 20 kW EHK-20B breakered heat strip, and connect the units with a 3/8" x 7/8" copper line set.
Condensing Unit & Air Handler Features
BOVB-60RTB-M15S Outdoor Condensing Unit
- 54,000 BTU/h cooling and 56,000 BTU/h heating in this matchup
- Inverter compressor runs at reduced speed when full capacity isn't needed
- 18.25 sq. ft. outdoor coil with 19 fins per inch
- Electronic expansion valve on the outdoor unit
- Heating range down to 3°F and cooling range up to 120°F outdoors
- Demand Defrost Control triggered by measured frost conditions
- Crankcase heater and compressor high temperature protection
- High/low voltage and over-current protection
- Line runs up to 100 ft with standard 7/8" suction
- Sound rating of 61.3 dB(A) at minimum load
BIVA-60RXB-M15X Multi-Position Air Handler
- Only IDS Light air handler with a 5-row all-aluminum coil
- 1/2 HP three-speed PSC blower, up to 2,157 CFM available
- Factory A2L refrigerant sensor with a 15-year service life
- Factory-installed R-454B TXV
- Accepts Bosch heat kits from 5 kW to 20 kW
- Upflow or horizontal right standard; field convertible to downflow or horizontal left
- Factory-sealed cabinet tested to 2% or less air leakage
- Integrated tool-less rack for a 20" x 22" filter
- Polymer drain pans with UV inhibitor and dual drain fittings
- 54-1/2" tall x 22" wide cabinet, 163 lbs. net
Specifications & Manuals
Product documentation includes condenser and air handler technical specifications, installation instructions, parts lists, warranty information and the Bosch product catalog to help with equipment selection, installation and service.
Frequently Asked Questions
What airflow is the 5 ton IDS Light system rated at?
Bosch's AHRI data lists 1,650 CFM for the BOVB-60RTB-M15S and BIVA-60RXB-M15X pairing. The air handler can deliver up to 2,157 CFM at zero static on high speed, but the duct system should be designed to hit the rated airflow at actual static pressure.
How is the 5 ton system different from the 4 ton system with the same condenser?
Both use the BOVB-60RTB-M15S outdoors. The 5 ton system swaps in the BIVA-60RXB-M15X air handler, which has a five-row coil and a 1/2 HP blower. That lifts capacity from 46,000 to 54,000 BTU/h of cooling and from 47,000 to 56,000 BTU/h of heating, at 14.3 SEER2.
How much do the two units weigh together?
The condenser weighs 181 lbs. net and the air handler 163 lbs. net, for a combined 344 lbs. before packaging. Plan for a sturdy condenser pad outdoors and confirm that attic platforms or stands can support the air handler.
How loud is the 5 ton system indoors and outdoors?
Bosch lists the condenser at 61.3 dB(A) at minimum load and 78.3 dB(A) at full load. The air handler is rated at 73.7 dB(A) on high speed. Because the inverter runs at reduced speed much of the time, typical operation sits closer to the lower figures.
Does registering the system change the warranty?
Yes. The 10-year residential limited warranty on the compressor and internal components applies either way. Registering online or through the Bosch EasyAir app within 90 days of installation adds a 90-day labor allowance for covered repairs.
Is the 5 ton system a good match for new construction?
Yes, when the Manual J load supports 5 tons and the ducts are designed for about 1,650 CFM. New construction makes it easy to size returns and trunks correctly from the start, and the R-454B system meets current refrigerant requirements for new installations.
Bosch IDS Light Condenser Technical Specifications
Bosch IDS Light Condenser Installation Instructions
Bosch IDS Light Condenser Parts List
Bosch IDS Light Warranty
Bosch IDS Light Air Handler Technical Specifications
Bosch IDS Light Air Handler Installation Instructions
Bosch IDS Light Air Handler Parts List
Bosch Catalog