decor decor

Summary

Product #52207: $2,130.00
  • Heat Strip:
2130
$2,130.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
BIVA-60RXB-M15X, 8733965422 | Full-Size 5-Row Coil Air Handler for Big-Home Heat Pump Systems

5 Ton Bosch IDS Light R-454B Air Handler, BIVA-60RXB-M15X

· SKU 52207 · Air Handler
Capacity
60,000 BTU
Refrigerant
R-454B
Cabinet Width
22"
Average Rating:
List price: $3,108.00

Our price:

$2,280.00

Sale price:

$2,130.00
You save $978.00!
  • SKU: 52207
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • Product Type:
    Air Handler
  • Tonnage:
    5
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    22"
  • Manufacturer Warranty:
    10 Years
  • 5kW Bosch Heat Strip, EHK-05A/WHE0502X
  • 8kW Bosch Heat Strip, EHK-08/WHE0802X
  • 10kW Bosch Heat Strip, EHK-10A/WHE1002X
  • 15kW Bosch Breakered Heat Strip, EHK-15B/WHE1502BX
  • 20kW Bosch Breakered Heat Strip, EHK-20B/WHE2002BX
Adding to cart… The item has been added

5 Ton Bosch IDS Light 15 SEER2 R-454B Multi-Position Air Handler, BIVA-60RXB-M15X

The Bosch BIVA-60RXB-M15X is the largest air handler in the IDS Light series and the only one with a five-row evaporator coil. That extra coil depth, plus a 1/2 HP three-speed PSC blower rated up to 2,157 CFM, gives full-size homes the airflow and coil surface a 5 ton heat pump needs. Matched with the Bosch BOVB-60RTB-M15S 5 ton inverter heat pump, it forms an AHRI-certified system rated at 54,000 BTU/h cooling and 56,000 BTU/h heating. It ships with a factory A2L leak sensor and R-454B TXV and accepts Bosch electric heat kits up to 20 kW, which makes it a good fit for large homes and new construction.

Is a 5 Ton Air Handler the Right Size?

The BIVA-60RXB-M15X is rated for 54,000 BTU/h of nominal cooling and 56,000 BTU/h of nominal heating. It's intended for large homes with heavy calculated loads. A 5 ton system needs roughly 1,500 to 2,250 CFM to stay within Bosch's 300 to 450 CFM per ton range. This blower delivers 1,802 CFM at 0.5" w.c. on high speed, so duct design and static pressure are critical.

Many existing homes have ductwork that can't move 5 tons of air without excess noise or high static. Confirm return sizing, supply trunk capacity and filter area before committing to this size. In some homes, the 4 ton indoor unit on the same condenser is the better match.

Ideal for: Large single-family homes, two-story homes with high loads, new construction and 5 ton heat pump replacements upgrading to R-454B.

Need less capacity? Consider the 4 Ton Bosch IDS Light R-454B Air Handler, BIVA-48RXB-M15X, which also pairs with the BOVB-60RTB-M15S.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, static pressure, air leakage and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Indoor Unit BIVA-60RXB-M15X — 5 Ton IDS Light Multi-Position Air Handler (Bosch Part No. 8733965422)
Matching Outdoor Unit Sold separately — Bosch BOVB-60RTB-M15S IDS Light Inverter Heat Pump
Application Split-System Heat Pump Air Handler — Upflow, Downflow, Horizontal Left or Right
Refrigerant R-454B with Factory-Installed A2L Refrigerant Sensor
Metering Device Factory-Installed R-454B TXV
Blower Motor 1/2 HP PSC, 3 Selectable Speeds
Electrical 208/230V, Single Phase, 60 Hz — 5.0 MCA / 15 A Max Overcurrent (without heat kit)
Line Connections 3/8" Liquid / 7/8" Suction (sweat)
Dimensions / Weight 24" D x 22" W x 54-1/2" H — 163 lbs. net

This listing is for the air handler only. The outdoor heat pump, heat kit and filter are sold separately. Paired with the BOVB-60RTB-M15S, the system is AHRI-rated at 54,000 BTU/h cooling, 56,000 BTU/h heating and 14.3 SEER2. The five-row, 5.99 sq. ft. coil and 1/2 HP blower make it the highest-airflow unit in the IDS Light lineup. Add backup heat with the 15 kW EHK-15B or 20 kW EHK-20B breakered heat strip, and connect to the outdoor unit with 3/8" x 7/8" copper line sets.

Air Handler Features & Matched Heat Pump Options

BIVA-60RXB-M15X IDS Light Air Handler

  • 54,000 BTU/h nominal cooling and 56,000 BTU/h nominal heating
  • Only IDS Light air handler with a 5-row all-aluminum evaporator coil
  • 1/2 HP PSC blower delivering up to 2,157 CFM on high speed
  • Factory-installed A2L refrigerant sensor with a 15-year service life
  • Factory-installed R-454B TXV
  • Large 54-1/2" cabinet with 19-1/2" supply duct opening
  • Cabinet sealed to 2% or less air leakage at 1.0" w.c.
  • Dual front panels and slide-out blower and coil for service
  • 20" x 22" filter in the integrated tool-less filter rack
  • Sound level of 73.7 dB(A) at high speed

Matched BOVB Heat Pump & Accessories

  • BOVB-60RTB-M15S inverter heat pump: 14.3 SEER2, 10 EER2
  • System capacity of 54,000 BTU/h cooling and 56,000 BTU/h heating
  • Accepts Bosch EHK-05B through EHK-20B breakered heat kits
  • Heat kit breakers provide short-circuit protection for each element
  • Compatible with most standard 24 VAC heat pump thermostats
  • Upflow or horizontal right standard; field convertible to horizontal left or downflow
  • Primary and secondary condensate drain fittings
  • Polymer drain pans with UV inhibitor
  • 25" front service clearance required
  • Choose the right air filtration for high-airflow systems

Specifications & Manuals

Product documentation includes technical specifications, airflow and heater kit data, installation instructions, a spare parts list, warranty terms and the Bosch product catalog to help with equipment selection, installation and service.

Frequently Asked Questions

What performance does the BIVA-60RXB-M15X deliver with the BOVB-60RTB-M15S?

Bosch's AHRI table rates the pair at 54,000 BTU/h cooling, 56,000 BTU/h heating, 14.3 SEER2 and 10 EER2. At 1,650 CFM, it is the highest-capacity system in the IDS Light lineup.

What separates the 5 ton BIVA-60RXB-M15X from the 4 ton BIVA-48RXB-M15X?

Both use the same 54-1/2" cabinet, but the 5 ton has a five-row coil instead of four rows and a stronger 1/2 HP blower in place of the 2/5 HP motor. That raises maximum airflow from 1,970 to 2,157 CFM and nominal cooling from 46,000 to 54,000 BTU/h.

How much airflow does a 5 ton system need?

Bosch requires 300 to 450 CFM per ton without electric heat and 350 to 450 CFM per ton with a heat kit. For 5 tons, that means roughly 1,500 to 2,250 CFM, so supply and return ducts must be sized for that volume.

How heavy is the BIVA-60RXB-M15X for attic or platform installs?

It weighs 163 lbs. net and about 195 lbs. packaged. Bosch warns that the supporting structure must be strong enough to carry the unit's weight. The unit should sit level, with up to an additional 1/4" of slope allowed toward the drain.

Does the A2L refrigerant sensor ever need to be replaced?

Yes. Bosch lists a 15-year service life for the R-454B leak sensor and recommends replacing it after that. Only the factory sensor or a Bosch-specified replacement model may be used, and it must stay powered at all times except during service.

What warranty covers the BIVA-60RXB-M15X?

In one- and two-family homes, Bosch warrants internal components for 10 years from the commencement date. Registering the product within 90 days adds a 90-day labor allowance. The unit must be installed and maintained by a licensed HVAC contractor.

Customer Review