decor decor

Summary

Product #179373: $4,710.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 41941 / 4 Ton Rheem Two Stage R454B Air Handler RH2TY4821STANNJ (179309) -- 1
  • 41963 / 4 Ton Rheem Two Stage R454B Heat Pump Condenser RP15AY48AJ2NA (179331) -- 1
4710
$4,710.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
RP15AY48AJ2NA, RH2TY4821STANNJ | 4 Ton Two-Stage Heat Pump with Up to 20 kW Backup Heat

4 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY48AJ2NA, RH2TY4821STANNJ

· SKU 179373 · AHRI 215415452 · Split System
SEER2
15.2
Capacity
48,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,727.00

Sale price:

$4,710.00
You save $1,017.00!
  • SKU: 179373
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    4
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    21"
  • AHRI Number:
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • 15 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RH1PY, RH2TY, RH2VY, RXBH-1724A15J-1, WRX1502BI
  • 20 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724A20J-1, WRX2002BI
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • Honeywell T6 Pro Thermostat 3H/2C Programmable TH6320U2008
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Honeywell T10 Pro Smart Wi-Fi Touchsrceen Thermostat 3H/2C Programmable w/ Sensor, THX321WFS2001W
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 4 Ton Rheem Two Stage R454B Air Handler RH2TY4821STANNJ
  • 4 Ton Rheem 15 SEER2 Two Stage R454B Heat Pump Condenser RP15AY48AJ2NA
Adding to cart… The item has been added

4 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY48AJ2NA, RH2TY4821STANNJ

For homes in colder service areas or with high heating demand, this 4 ton Rheem system pairs the RP15AY48AJ2NA two-stage heat pump with the RH2TY4821STANNJ air handler and supports up to a 20 kW breakered backup heat strip. Rated 15.2 SEER2 under AHRI #215415452 on R-454B refrigerant, it serves larger two-story homes and high-load spaces that need strong airflow and dependable heat on the coldest mornings.

Is a 4 Ton Heat Pump System the Right Size?

Rheem rates this match at 45,500 BTU/h of cooling, 44,000 BTU/h of heating at 47°F, and 29,600 BTU/h at 17°F. That fits larger homes, houses with high ceilings or extensive glass, and hot-climate homes with long cooling seasons.

Airflow is the make-or-break factor at 4 tons. Supply and return ducts must be sized to carry the higher airflow without whistling registers or a noisy return. Insulation, climate, and how the home is used still drive the load, so confirm with a calculation before choosing between 3.5, 4, and 5 tons.

Ideal for: Larger two-story homes, homes with vaulted ceilings or lots of glass, colder-climate homes needing larger backup heat, and replacement of an existing 4 ton heat pump.

Need more capacity? Step up to the 5 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY60AJ2NA, RH2TY6024STANNJ, the largest system in this series.

Recommended system sizes are general guidelines only. Actual heating and cooling requirements depend on insulation, climate, windows, ductwork, ceiling height, and occupancy. A Manual J load calculation is the best way to confirm sizing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump RP15AY48AJ2NA — 4 Ton R-454B Two-Stage Heat Pump
Indoor Air Handler RH2TY4821STANNJ — 3.5-4 Ton Two-Stage Multipoise Air Handler with TXV
System Rating 15.2 SEER2, 11.7 EER2, 7.8 HSPF2, 45,500 BTU/h Cooling, AHRI #215415452
Refrigerant R-454B (A2L, Low GWP)
Compressor Two-Stage Scroll Compressor
Defrost Demand Defrost Control
Electrical 208/230V, Single Phase, 60 Hz Heat Pump — MCA 27 A, Max Breaker 45 A
Air Handler Electrical 208-240V, Single Phase — 3/4 HP Constant Torque Motor, 21" Cabinet

This package uses the same RH2TY4821STANNJ air handler and 39" outdoor cabinet as the 3.5 ton system but adds a larger compressor and opens up a 20 kW breakered Rheem heat strip option. Plan for a 7/8" x 3/8" copper line set (offered on this listing), a 45 A maximum breaker, and a solid condenser pad for the 240 lb outdoor unit.

Heat Pump & Air Handler Features

RP15AY48AJ2NA Outdoor Heat Pump

  • Two-stage scroll compressor (20 RLA, 141 LRA)
  • 29,600 BTU/h heating at 17°F per Rheem tested data
  • 7 mm copper tube condenser coil
  • Demand defrost control
  • 130 oz R-454B factory charge
  • 7/8" suction and 3/8" liquid service valves
  • PlusOne® Refrigerant Detection System
  • PlusOne® Triple Service Access
  • 39" H x 35-3/4" W x 35-3/4" L cabinet, 240 lbs
  • Internal pressure relief valve and thermal overload

RH2TY4821STANNJ Multi-Position Air Handler

  • Full 4 ton rating with two-stage airflow
  • 3/4 HP constant torque (ECM) motor
  • Nominal airflow of 1,400 CFM low / 1,600 CFM high
  • 21" wide cabinet
  • Factory TXV and A2L refrigerant sensor
  • 4-way convertible installation
  • 1" foil-faced insulation
  • Heater kits include circuit breakers for service disconnect
  • Side or top electrical connection provisions
  • Accepts heat strips up to 20 kW breakered on this listing

Specifications & Manuals

Documentation includes RP15AY 4 ton capacity and electrical data, cold-weather heating performance, RH2TY airflow and heater kit tables, plus installation and warranty details.

Frequently Asked Questions

When does a 4 ton RP15AY48AJ2NA heat pump make sense?

When a load calculation shows roughly 48,000 BTU/h, which is common in larger two-story homes, homes with high ceilings, and hot climates with long cooling seasons.

What is the difference between the 3.5 ton and 4 ton RP15AY systems?

Both use the RH2TY4821STANNJ and the same 39" outdoor cabinet with a 130 oz charge. The 4 ton adds about 5,500 BTU/h of cooling, supports a 20 kW heat strip, and needs a 45 A maximum breaker versus 40 A.

What size breaker does the RP15AY48AJ2NA need?

Rheem lists a 27 A minimum circuit ampacity and a 45 A maximum overcurrent protection using an HACR breaker or fuse.

Can this 4 ton system help with humidity control?

Yes. Two-stage operation runs longer at low speed for better moisture removal, and Rheem's installation instructions include wiring for two-stage thermostats with dehumidification.

What is the largest heat strip for the 4 ton system?

This listing offers up to a 20 kW breakered heat strip (RXBH-1724A20J-1), along with 5, 8, 10, and 15 kW options.

What airflow does the RH2TY4821STANNJ deliver?

Rheem lists nominal airflow of 1,400 CFM on low stage and 1,600 CFM on high stage for the RH2TY4821 air handler.