4 Ton Bosch IDS Light 15 SEER2 R-454B Multi-Position Air Handler, BIVA-48RXB-M15X
There's no 4 ton IDS Light condenser, so the Bosch BIVA-48RXB-M15X is how you build a 4 ton IDS Light system. Bosch AHRI-rates it with the BOVB-60RTB-M15S inverter heat pump at 46,000 BTU/h cooling, 47,000 BTU/h heating and 14.3 SEER2. It uses the larger 54-1/2" IDS Light cabinet, with a 5.99 sq. ft. all-aluminum coil, a 2/5 HP three-speed PSC blower and a 7/8" suction connection. Like every IDS Light air handler, it ships with a factory-installed A2L sensor and R-454B TXV, and it accepts electric heat kits up to 20 kW for larger homes in colder areas.
Is a 4 Ton Air Handler the Right Size?
The BIVA-48RXB-M15X is rated for 46,000 BTU/h of cooling and 47,000 BTU/h of heating. That suits larger homes that need more than a 3 ton system but don't call for a full 5 tons. At high speed, its blower delivers up to 1,970 CFM at zero static and about 1,580 CFM at 0.5" w.c., which keeps most 4 ton duct systems inside Bosch's 300 to 450 CFM per ton window.
Because the matching outdoor unit is the 5 ton BOVB-60RTB-M15S, the inverter compressor modulates down to the 4 ton indoor load. Duct sizing still decides real performance. A 4 ton system typically needs larger supply and return trunks than a 3 ton system. Check static pressure before you reuse old ductwork.
Ideal for: Larger single-family homes, two-story houses on one system and 4 ton heat pump replacements that are converting to R-454B.
Need more capacity? Step up to the 5 Ton Bosch IDS Light R-454B Air Handler, BIVA-60RXB-M15X for homes needing about 54,000 BTU/h of cooling.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, static pressure, air leakage and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Indoor Unit | BIVA-48RXB-M15X — 4 Ton IDS Light Multi-Position Air Handler (Bosch Part No. 8733965421) |
|---|---|
| Matching Outdoor Unit | Sold separately — Bosch BOVB-60RTB-M15S IDS Light Inverter Heat Pump |
| Application | Split-System Heat Pump Air Handler — Upflow, Downflow, Horizontal Left or Right |
| Refrigerant | R-454B with Factory-Installed A2L Refrigerant Sensor |
| Metering Device | Factory-Installed R-454B TXV |
| Blower Motor | 2/5 HP PSC, 3 Selectable Speeds |
| Electrical | 208/230V, Single Phase, 60 Hz — 4.3 MCA / 15 A Max Overcurrent (without heat kit) |
| Line Connections | 3/8" Liquid / 7/8" Suction (sweat) |
| Dimensions / Weight | 24" D x 22" W x 54-1/2" H — 157 lbs. net |
This listing is for the air handler only. The outdoor heat pump, heat kit and filter are sold separately. Matched with the BOVB-60RTB-M15S, Bosch rates the system at 46,000 BTU/h cooling, 47,000 BTU/h heating, 14.3 SEER2 and 11 EER2. The 4 ton cabinet takes the full Bosch breakered heat kit range, from 5 kW up to the 20 kW EHK-20B dual-circuit heat strip. Browse all Bosch electric heat strips to choose the right backup heat for your climate.
Air Handler Features & Matched Heat Pump Options
BIVA-48RXB-M15X IDS Light Air Handler
- 46,000 BTU/h nominal cooling and 47,000 BTU/h nominal heating
- Larger 5.99 sq. ft., 4-row all-aluminum evaporator coil
- 2/5 HP PSC blower with low, medium and high speed taps
- Factory-installed A2L refrigerant sensor triggers maximum blower speed on a leak
- Factory-installed, non-adjustable R-454B TXV
- 7/8" suction and 3/8" liquid sweat connections
- Fully insulated cabinet sealed to 2% or less air leakage
- Integrated tool-less filter rack sized for 20" x 22" filters
- Horizontal and vertical polymer drain pans with UV inhibitor
- Sound level of 72.4 dB(A) at high speed
Matched BOVB Heat Pump & Accessories
- BOVB-60RTB-M15S inverter heat pump: 14.3 SEER2, 11 EER2
- System capacity of 46,000 BTU/h cooling and 47,000 BTU/h heating
- Accepts Bosch EHK-05B, EHK-08B, EHK-10B, EHK-15B and EHK-20B kits
- 15 and 20 kW kits use two heater elements on two circuits
- Standard 24 VAC heat pump thermostat compatible
- 2H thermostats run single-stage auxiliary heat; 3H thermostats run two stages
- Electrical entry through the top or either side
- 3/4" NPT primary and auxiliary drain connections
- 25" front clearance required for filter and coil access
- Pair with a compatible heat pump thermostat or control
Specifications & Manuals
Product documentation includes technical specifications, airflow and heater kit data, installation instructions, a spare parts list, warranty terms and the Bosch product catalog to help with equipment selection, installation and service.
Frequently Asked Questions
Which condenser do I use with a 4 ton BIVA-48RXB-M15X?
The IDS Light series doesn't include a 4 ton condenser. Bosch pairs this air handler with the BOVB-60RTB-M15S inverter heat pump, which modulates to deliver an AHRI-rated 46,000 BTU/h of cooling and 47,000 BTU/h of heating with the 4 ton indoor unit.
How is the 4 ton BIVA-48RXB-M15X different from the 3 ton BIVA-36RXB-M15X?
The 4 ton unit uses a larger 54-1/2" tall, 22" wide cabinet with a 5.99 sq. ft. coil, compared with 4.02 sq. ft. It has a 2/5 HP blower instead of 1/3 HP, a 7/8" suction connection instead of 3/4", and takes a 20" x 22" filter instead of an 18" x 20".
Does the 4 ton air handler support 15 kW and 20 kW heat kits?
Yes. Bosch lists the EHK-15B and EHK-20B for the 4 ton cabinet. Both are dual-circuit kits with two heater elements, so plan for two supply circuits. Bosch notes that these larger kits run with the blower on high speed.
Do I need a special thermostat for the BIVA-48RXB-M15X?
No. Bosch states that this air handler works with most standard 24 VAC heat pump thermostats. Choose a 3H thermostat if you plan to run a two-stage electric heat kit.
Why does cabinet air leakage matter on this air handler?
Air that leaks from the cabinet never reaches your rooms and can pull in unconditioned attic or garage air. Bosch factory-seals this cabinet and certifies it at 2% or less leakage at 1.0" of water column, which helps the system deliver its rated capacity.
Is the metering device already installed?
Yes. A non-adjustable R-454B thermostatic expansion valve comes installed from the factory, so no field metering kit is needed when pairing with the BOVB-60RTB-M15S.