2 Ton Rheem 17 SEER2 R454B Inverter Heat Pump System RP17AY24AJVCA, RH2TY2417STANNJ
This complete 2-ton Rheem heat pump system pairs the inverter-driven RP17AY24AJVCA outdoor condenser with the RH2TY2417STANNJ two-stage air handler for R-454B refrigerant. The inverter compressor modulates from 35% to 100% capacity while the constant-torque ECM air handler moves conditioned air efficiently, giving smaller homes, condos, and additions a factory-matched, AHRI-certified system rated at 17 SEER2 and up to 9.5 HSPF2.
Is the 2 Ton System the Right Size?
A 2-ton system generally fits smaller or well-insulated homes of roughly 900 to 1,300 square feet, but the correct capacity always comes from a load calculation rather than square footage alone.
Insulation, window area, ceiling height, ductwork, and climate all move the real load. Because the RP17AY24AJVCA is inverter-driven, the system holds temperature precisely even at part load, but a Manual J calculation is the best way to confirm a nominal 2-ton system is right for your space.
Ideal for: compact single-family homes, condos, townhomes, and additions that want a complete, quiet, right-sized inverter system.
Need more capacity? Step up to the 3 Ton Rheem RP17AY36AJVCA Heat Pump System for larger family homes.
Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, window load, and air-sealing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condenser | RP17AY24AJVCA – 2 Ton Inverter-Driven Heat Pump |
|---|---|
| Indoor Air Handler | RH2TY2417STANNJ – 2 Ton Two-Stage Constant-Torque ECM |
| System Efficiency | 17 SEER2 (AHRI-certified matched system) |
| Nominal Capacity | 2 Tons (24,000 BTU class) |
| Heating Output | Up to 22,600 BTU/h @ 47°F / up to 9.5 HSPF2 |
| Refrigerant | R-454B (A2L, low GWP) |
| Electric Heat Kit | Field-installed (5/8/10 kW) – sold separately |
The RH2TY2417STANNJ is a compact multi-position air handler (upflow, downflow, and horizontal) with a factory-ready A2L refrigerant detection location. The outdoor unit ships with a bi-flow liquid-line filter drier and the integrated PlusOne Refrigerant Detection System.
Condenser & Air Handler Features
RP17AY24AJVCA Condenser
- Inverter-driven PlusOne variable-speed compressor modulates 35%–100%
- Quiet operation as low as 55 dBA with sound blanket and swept-wing fan
- 7mm copper coil and brushless DC condenser motor for efficiency and reliability
- EcoNet-capable outdoor control with PlusOne Diagnostics & Bluetooth
- 10-year conditional parts warranty with registration
RH2TY2417STANNJ Air Handler
- Two-stage constant-torque ECM motor for steady, efficient airflow
- Multi-position cabinet for flexible upflow, downflow, or horizontal installs
- Built for R-454B with a factory A2L refrigerant-detection location
- Accepts field-installed electric heat kits for supplemental heat
- Non-communicating design controlled by a standard 24V thermostat
Because the RH2TY air handler is not EcoNet enabled, this system is controlled by a conventional 24V thermostat. We recommend the ecobee Smart Thermostat Lite (EB-STATE7P-01). Using the Rheem algorithm, the inverter condenser delivers full variable-speed operation with the utility 1 & 2 jumpers installed, or two-stage (70% and 100%) operation without them. To move up to full EcoNet communicating control with the Rheem EcoNet Smart Thermostat, pair the condenser with the variable-speed RH2VY2417STACNJ EcoNet air handler instead.
Specifications & Manuals
Product documentation includes condenser and air handler technical specifications, installation instructions, the R-454B charge chart, and warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
What is included in this 2-ton RP17AY24AJVCA / RH2TY2417STANNJ system?
It is a matched split system with the RP17AY24AJVCA inverter-driven outdoor condenser and the RH2TY2417STANNJ two-stage air handler. An electric heat kit is optional and sold separately.
Is the RH2TY2417STANNJ air handler EcoNet enabled?
No. It is a two-stage constant-torque ECM air handler that is non-communicating, so it operates with a conventional 24V thermostat rather than the EcoNet communicating platform.
Which thermostat is recommended for this 2-ton system?
Because the air handler is not EcoNet enabled, we recommend the ecobee Smart Thermostat Lite, model EB-STATE7P-01, which works well with this inverter condenser on a standard 24V connection.
Can I still get variable-speed operation with the RH2TY air handler?
Yes. Using the Rheem algorithm, the RP17AY24AJVCA runs full variable speed when the utility 1 and 2 jumpers are installed, or two-stage (70% and 100%) operation when they are not.
Does the 2-ton air handler include an electric heat kit?
No. Field-installed electric heat kits (commonly 5, 8, or 10 kW) are available separately and selected based on your backup-heat requirements.
What SEER2 is this matched 2-ton system rated at?
The RP17AY24AJVCA and RH2TY2417STANNJ combination is AHRI-certified at 17 SEER2.


RP17AY Technical Specifications
RP17AY Brochure
RP17AY Charge Chart
RP17AY Submittal Sheet
RP17AY Installation Instructions
RH2TY Technical Specifications
RH2TY Installation Instructions
Rheem Warranty Certificate