2 Ton Rheem 16 SEER2 R454B Variable Speed Inverter Heat Pump System RP17AY24AJVCA, RH2VY2417STACNJ
This 2-ton Rheem system pairs the inverter-driven RP17AY24AJVCA condenser with the EcoNet-enabled RH2VY2417STACNJ variable-speed air handler for R-454B refrigerant. When both units communicate over EcoNet, the Constant CFM air handler and inverter compressor auto-adjust together from low capacity to 100%, delivering exceptional humidity control, quiet operation, and an AHRI-certified 16 SEER2 / 11.7 EER2 rating with up to 9.0 HSPF2 heating for smaller homes.
Is the 2 Ton System the Right Size?
A 2-ton system generally suits smaller or well-insulated homes of roughly 900 to 1,300 square feet, though a load calculation, not square footage, is what confirms the fit.
Insulation, windows, ceiling height, ductwork, and climate all move the real load. This fully communicating pairing modulates airflow and capacity in fine steps for excellent comfort even at part load, but a Manual J calculation is the best way to confirm a nominal 2-ton system matches your space.
Ideal for: compact homes, condos, and additions that want the quietest, most precise communicating comfort in a right-sized system.
Need more capacity? Step up to the 3 Ton Rheem RP17AY36AJVCA Variable Speed System for larger family homes.
Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, window load, and air-sealing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condenser | RP17AY24AJVCA – 2 Ton Inverter-Driven Heat Pump |
|---|---|
| Indoor Air Handler | RH2VY2417STACNJ – 2 Ton EcoNet Variable-Speed (Constant CFM) |
| System Efficiency | 16 SEER2 / 11.7 EER2 / 9.0 HSPF2 (AHRI-certified) |
| Cooling Capacity | 22,800 BTU/h (AHRI-matched) |
| Heating Capacity | 22,600 BTU/h @ 47°F / 19,700 BTU/h @ 17°F |
| Refrigerant | R-454B (A2L, low GWP) |
| Air Handler Cabinet | 17.5" wide, 4-way convertible • 1/3 HP ECM |
| Electric Heat Kit | Field-installed RXBH kit – sold separately |
The RH2VY2417STACNJ uses a Constant CFM ECM motor with a TXV, an aluminum indoor coil, and 1-inch foil-faced insulation for quiet operation and less than 2% cabinet air leakage. Both units include an integrated PlusOne Refrigerant Detection System, and the air handler commissions dip-switch-free over Bluetooth.
Condenser & Air Handler Features
RP17AY24AJVCA Condenser
- Inverter-driven PlusOne variable-speed compressor modulates 35%–100%
- Quiet operation as low as 55 dBA with sound blanket and swept-wing fan
- 7mm copper coil and brushless DC condenser motor for efficiency
- EcoNet enabled with PlusOne Diagnostics & Bluetooth
- 10-year conditional parts warranty with registration
RH2VY2417STACNJ Air Handler
- EcoNet-enabled Constant CFM (variable-speed) ECM motor, two-stage airflow
- TXV metering and corrosion-resistant aluminum indoor coil
- 4-way convertible for upflow, downflow, and horizontal left/right
- Dip-switch-free Bluetooth commissioning via the Rheem Contractor App
- Accepts field-installed RXBH electric heat kits
Because both the condenser and the RH2VY air handler are EcoNet enabled, this is a fully communicating system. We recommend installing the Rheem EcoNet Smart Thermostat so the system auto-configures and gradually modulates capacity and airflow together for the best efficiency, humidity control, and quiet operation, plus remote monitoring and service alerts through the EcoNet app.
Specifications & Manuals
Product documentation includes condenser and air handler technical specifications, installation instructions, the R-454B charge chart, and warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
Is this 2-ton system fully communicating?
Yes. Both the RP17AY24AJVCA condenser and the RH2VY2417STACNJ air handler are EcoNet enabled, so with the EcoNet Smart Thermostat they communicate and optimize as one system.
What thermostat should I use with this 2-ton EcoNet system?
Because both units are EcoNet equipped, we recommend the Rheem EcoNet Smart Thermostat, which unlocks automatic configuration, fine modulation, and app-based monitoring.
How does the RH2VY air handler differ from the RH2TY?
The RH2VY uses an EcoNet-enabled Constant CFM variable-speed motor for finer airflow control and communicating operation, while the RH2TY is a non-communicating two-stage constant-torque model.
Why is this 2-ton system rated 16 SEER2?
16 SEER2 with 11.7 EER2 and 9.0 HSPF2 is the AHRI-certified rating for the RP17AY24AJVCA and RH2VY2417STACNJ combination.
Does the RH2VY2417STACNJ include a TXV?
Yes. The air handler uses a factory thermal expansion valve (TXV) as its metering device, matched for R-454B operation.
Can I add electric backup heat to this 2-ton system?
Yes. Field-installed RXBH heater kits with built-in service-disconnect breakers are available separately and sized to your backup-heat needs.


RP17AY Technical Specifications
RP17AY Brochure
RP17AY Charge Chart
RP17AY Submittal Sheet
RP17AY Installation Instructions
RH2VY Technical Specifications
RH2VY Installation Instructions
Rheem Warranty Certificate




