decor decor

Summary

Product #180013: $2,630.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 42067 / 2 Ton EcoTemp R454B Heat Pump Condenser W5H5S24AKAAA (179443) -- 1
  • 45979 / 2 Ton EcoTemp R454B Air Handler FMA5L2400AL ( 179788) -- 1
2630
$2,630.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?

2 Ton EcoTemp 14.5 SEER2 R454B Heat Pump Wall Mount Apartment/Condo Type System W5H5S24AKAAA, FMA5L2400AL

· SKU 180013 · AHRI 214424002 · Split System
SEER2
14.5
Capacity
24,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $3,420.00

Sale price:

$2,630.00
You save $790.00!
  • SKU: 180013
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.5
  • Product Type:
    Split System
  • Tonnage:
    2
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    20.5"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • EcoTemp 5 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK205B/ WFM0502B
  • EcoTemp 7.5 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK208B/ WFM0802B
  • EcoTemp 10 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK210B/ WFM1002B
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2 Ton EcoTemp 14.3 SEER2 R454B Heat Pump Condenser W5H5S24AKAAA
  • 2 Ton EcoTemp R454B Wall Mount Apartment/Condo Type PSC Motor Air Handler FMA5L2400AL
Adding to cart… The item has been added

2 Ton EcoTemp 14.5 SEER2 R454B Heat Pump Wall Mount Apartment/Condo Type System W5H5S24AKAAA, FMA5L2400AL

The EcoTemp W5H5S24AKAAA and FMA5L2400AL make up a matched 24,000 BTU heat pump system for multifamily closets. It carries an AHRI-certified 14.5 SEER2 rating (AHRI #214424002) and runs on low-GWP R-454B. It is the middle size many apartment and condo units are built around: enough capacity for a typical one- or two-bedroom layout, in the same slim 20-1/2" wall-hung cabinet as the 1.5 ton. For landlords and maintenance teams handling turnovers, it offers dependable heating and cooling, a simple PSC blower and front-access service.

Is a 2 Ton Heat Pump System the Right Size?

A 2 ton system fits units whose combined heating and cooling load lands near 24,000 BTU per hour. Building owners often pick this size when a 1.5 ton unit runs constantly on hot afternoons, but a 2.5 ton would short-cycle and leave the space clammy. In apartments, sizing has as much to do with the unit's position in the building as with floor area.

An end unit with three exposed walls and west-facing glass can need noticeably more capacity than an interior unit of the same size. Occupancy, cooking loads, insulation quality and ceiling height matter too. The HVAC sizing calculator is a quick way to check whether 2 tons matches your load.

Ideal for: One-bedroom and smaller two-bedroom apartments, mid-size condos, townhome-style rental units and replacement of existing 2 ton wall-hung fan coil systems.

Need more capacity? Step up to the 2.5 Ton EcoTemp 14.3 SEER2 R454B Heat Pump Wall Mount System W5H5S30AKAAA, FMA5L3000AL for larger units or high-exposure floor plans.

Recommended system sizes are general guidelines only. Actual requirements depend on climate, insulation, unit location within the building, window exposure, occupancy, and installation conditions. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump W5H5S24AKAAA — 2 Ton Single-Stage R-454B Heat Pump
Indoor Fan Coil FMA5L2400AL Wall-Hung Multifamily Fan Coil (PSC Motor)
Application Apartment / Condo Split System Heat Pump, Heating & Cooling
Refrigerant R-454B (Low-GWP A2L)
Compressor Single-Stage Scroll Compressor
Efficiency 14.5 SEER2, AHRI Certified #214424002
Electrical 208/230V, Single Phase, 60 Hz Heat Pump (13.5 MCA / 20 Amp Max Fuse or Breaker)
Fan Coil Electrical 208/230V, Single Phase, 60 Hz

The W5H5S24AKAAA heat pump has a 3,500 CFM vertical-discharge fan and a 19.3 sq. ft. outdoor coil, and it is rated at 71 dBA. The FMA5L2400AL uses the same compact 36-1/2" x 20-1/2" x 15" cabinet as the 1.5 ton model but steps up to a 1/5 HP PSC blower rated at 800 CFM nominal. That lets you upsize the system without reframing an existing closet. Add backup heat with a 5, 7.5 or 10 kW breakered heat kit from the options on this page. For a 2 ton install, 3/4" x 3/8" is an acceptable line size, for example a 25 ft. 3/4 & 3/8 copper line set.

Heat Pump & Fan Coil Features

W5H5S24AKAAA Outdoor Heat Pump

  • Single-stage scroll compressor on low-GWP R-454B refrigerant
  • 71 dBA standard sound rating, or 68 dBA with the optional sound blanket
  • 3,500 CFM vertical-discharge, direct-drive outdoor fan
  • Loss of charge switch and suction line accumulator
  • Internal thermal overload and internal pressure relief valve
  • Front-seating service valves with a field-installed filter drier
  • Long-line rated up to 250 ft. total equivalent length with required accessories
  • Low ambient cooling to 0°F with approved accessory kits
  • Supports both programmable and standard thermostats
  • Durable sheet metal construction with a dense wire coil guard

FMA5L2400AL Wall-Hung Fan Coil

  • 1/5 HP, 3-speed PSC blower delivering 800 CFM nominal
  • Compact 20-1/2" wide cabinet, the same footprint as the 1.5 ton model
  • Factory TXV metering on an all-aluminum coil
  • Integrated refrigerant leak detection for A2L refrigerant
  • Blower motor suspended on rubber grommets for quieter operation
  • Fresh air intake knockouts built into the cabinet
  • Accepts circuit-breaker-protected 5, 7.5 or 10 kW electric heat
  • Upflow wall-hung installation with brackets included
  • Front-return design, field-convertible to bottom return
  • 15.5" x 19.5" x 0.75" filter and 3/4" FPT primary and secondary drains

Specifications & Manuals

Documentation covers W5H5S heat pump performance and installation data, FMA5L fan coil specifications, wiring, service procedures, warranty terms, and product literature for selection, installation, and maintenance.

Frequently Asked Questions

How do I confirm a 2 ton heat pump is right for my condo unit?

Start with a load estimate that accounts for your unit's exposed walls, windows, floor level and insulation. If the result is near 24,000 BTU, the W5H5S24AKAAA / FMA5L2400AL is a good match. Our team can help with free sizing if you send the unit details.

What changes when stepping up from the 1.5 ton to the 2 ton W5H5S24AKAAA system?

The fan coil cabinet stays the same size, but the FMA5L2400AL's 1/5 HP blower moves 800 CFM nominal versus 650 CFM on the 1.5 ton. Outdoors, the W5H5S24AKAAA has a larger coil and a 3,500 CFM fan. This pairing is also rated slightly higher, at 14.5 SEER2 compared with 14.3 SEER2 for the 1.5 ton W5H5S18AKAAA system.

What breaker size does the W5H5S24AKAAA outdoor unit require?

The W5H5S24AKAAA lists a minimum circuit ampacity of 13.5 amps and a maximum time-delay fuse or circuit breaker of 20 amps at 208/230V single phase. The fan coil, plus any electric heat kit, is wired on its own circuit. Size it from the fan coil and heater data.

Which electric heat strips are available for the FMA5L2400AL?

The FMA5L2400AL accepts circuit-breaker-protected electric heaters in 5, 7.5 or 10 kW. On this page they're listed as EHK205B, EHK208B and EHK210B. Larger kits give more backup and emergency heat in colder weather.

How loud is the W5H5S24AKAAA heat pump outdoors?

The W5H5S24AKAAA has a standard sound power rating of 71 dBA. With the optional accessory sound blanket it drops to 68 dBA, which helps where units sit close to balconies, patios or neighboring windows.

Why is R-454B used in this 2 ton EcoTemp system instead of R-410A?

R-454B is a non-ozone-depleting refrigerant with much lower global warming potential, and it meets current requirements for new residential heating and cooling equipment. Because it is an A2L refrigerant, the FMA5L2400AL fan coil includes a refrigerant leak detection system.

Customer Review