decor decor

Summary

Product #180017: $3,080.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 42067 / 2 Ton EcoTemp R454B Heat Pump Condenser W5H5S24AKAAA (179443) -- 1
  • 45974 / 2 Ton EcoTemp R454B Air Handler FMA5X2400AL ( 179784) -- 1
3080
$3,080.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?

2 Ton EcoTemp 15.5 SEER2 R454B Heat Pump Wall Mount Apartment/Condo Type System W5H5S24AKAAA, FMA5X2400AL

· SKU 180017 · AHRI 214424066 · Split System
SEER2
15.5
Capacity
24,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $3,999.00

Sale price:

$3,080.00
You save $919.00!
  • SKU: 180017
  • Availability:
    CURRENTLY UNAVAILABLE
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    15.5
  • Product Type:
    Split System
  • Tonnage:
    2
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    20.5"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • EcoTemp 5 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK205B/ WFM0502B
  • EcoTemp 7.5 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK208B/ WFM0802B
  • EcoTemp 10 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK210B/ WFM1002B
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2 Ton EcoTemp 14.3 SEER2 R454B Heat Pump Condenser W5H5S24AKAAA
  • 2 Ton EcoTemp R454B Wall Mount Apartment/Condo Type ECM Motor Air Handler FMA5X2400AL
Adding to cart… The item has been added

2 Ton EcoTemp 15.5 SEER2 R454B Heat Pump Wall Mount Apartment/Condo Type System W5H5S24AKAAA, FMA5X2400AL

At 15.5 SEER2 (AHRI #214424066), this 24,000 BTU EcoTemp package ties with the 3 ton ECM system for the highest efficiency in the multifamily heat pump lineup. It matches the W5H5S24AKAAA R-454B heat pump with the FMA5X2400AL wall-hung fan coil and its constant-torque ECM blower. It suits condo owners who want lower utility bills and quieter, steadier airflow, and property managers trying to cut energy costs across a building of mid-size units.

Is a 2 Ton Heat Pump System the Right Size?

This system is built for loads around 24,000 BTU per hour, the sweet spot for many one-bedroom and modest two-bedroom units. Getting the size right is especially important with a high-efficiency system. Rated SEER2 savings only show up when the heat pump runs full, steady cycles, rather than short-cycling because it is oversized.

Look at more than floor area. Count exterior walls, note the direction of the main windows, check whether the unit sits under a roof, and consider how many people live there. Estimate your load with the BTU and tonnage calculator, and read the SEER2 efficiency guide to see how this rating compares.

Ideal for: One-bedroom and compact two-bedroom condos, owner-occupied units focused on energy savings, and efficiency upgrades from older 2 ton fan coil systems.

Need more capacity? Step up to the 2.5 Ton EcoTemp 15.2 SEER2 R454B Heat Pump Wall Mount System W5H5S30AKAAA, FMA5X3000AL for larger units that need more ECM airflow.

Recommended system sizes are general guidelines only. Actual requirements depend on climate, insulation, unit location within the building, window exposure, occupancy, and installation conditions. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump W5H5S24AKAAA — 2 Ton Single-Stage R-454B Heat Pump
Indoor Fan Coil FMA5X2400AL Wall-Hung Multifamily Fan Coil (ECM Motor)
Application Apartment / Condo Split System Heat Pump, Heating & Cooling
Refrigerant R-454B (Low-GWP A2L)
Compressor Single-Stage Scroll Compressor
Efficiency 15.5 SEER2, AHRI Certified #214424066
Electrical 208/230V, Single Phase, 60 Hz Heat Pump (13.5 MCA / 20 Amp Max Fuse or Breaker)
Fan Coil Electrical 208/230V, Single Phase, 60 Hz

The FMA5X2400AL ships with its 1/3 HP ECM blower on Tap 5, the highest of its five speeds, to deliver the 800 CFM nominal a 2 ton heat pump needs. It is housed in the compact 20-1/2" wide cabinet shared with the 1.5 ton size. The W5H5S24AKAAA outdoor unit has a 19.3 sq. ft. coil and a 3,500 CFM fan. A 3/4" x 3/8" line set such as the 50 ft. 3/4 & 3/8 copper line set is an acceptable size for this system. The outdoor unit is also available separately as the W5H5S24AKAAA heat pump condenser. Optional 5, 7.5 and 10 kW breakered heat kits are available on this page.

Heat Pump & Fan Coil Features

W5H5S24AKAAA Outdoor Heat Pump

  • Part of a 15.5 SEER2 AHRI-certified match with the FMA5X2400AL
  • Single-stage scroll compressor on R-454B refrigerant
  • 19.3 sq. ft. single-row coil with 20 fins per inch
  • 3,500 CFM vertical-discharge fan with a 1/10 HP motor
  • 71 dBA rating, or 68 dBA with the optional sound blanket
  • Loss of charge switch, accumulator and internal pressure relief
  • Front-seating service valves and a field-installed filter drier
  • Optional hard start, time delay relay and cycle protector kits
  • Low ambient cooling capability to 0°F with kit
  • Long line capable up to 250 ft. total equivalent length

FMA5X2400AL Wall-Hung Fan Coil

  • 1/3 HP 5-speed constant-torque ECM blower
  • Tap 5 factory setting delivers 800 CFM nominal
  • Compact 36-1/2" x 20-1/2" x 15" wall-hung cabinet
  • Integrated refrigerant leak detection for A2L safety
  • TXV-metered all-aluminum coil
  • Motor mounted on rubber grommets to reduce vibration
  • Primary and secondary 3/4" FPT drains exit from the bottom
  • Free-air return design for qualifying single-level applications
  • Insulated galvanized cabinet for conditioned spaces
  • Accepts 5, 7.5 or 10 kW circuit-breaker-protected heat

Specifications & Manuals

Documentation for this 2 ton ECM system includes heat pump and fan coil specifications, blower performance tables, installation and wiring instructions, a service manual, and warranty terms.

Frequently Asked Questions

What size condo is a 2 ton 15.5 SEER2 heat pump typically considered for?

It suits condos and apartments with a calculated load near 24,000 BTU, often one-bedroom and smaller two-bedroom layouts. The load depends on exposure, insulation and occupancy, so confirm with a sizing calculation before ordering.

How is the 2 ton FMA5X2400AL system different from the 1.5 ton FMA5X version?

Both use the same 20-1/2" cabinet and 1/3 HP ECM motor. The 2 ton FMA5X2400AL ships on Tap 5 for 800 CFM nominal, while the 1.5 ton FMA5X1800AL system ships on Tap 3 for 650 CFM. The 2 ton pairing is also rated higher, at 15.5 SEER2 versus 15.2.

Is there a cooling-only version of this 2 ton wall-mount system?

Yes. If the building uses another heat source, the 2 Ton EcoTemp W5A5S24AKAWA, FMA5X2400AL air conditioning system uses the same ECM fan coil with an AC-only condenser. This heat pump version provides both heating and cooling.

What is the factory blower setting on the FMA5X2400AL?

The 2 ton FMA5X2400AL ships on Tap 5 of its 5-speed ECM motor. The manufacturer's blower tables list airflow at each tap across a range of external static pressures, so installers can fine-tune airflow if the duct system needs it.

What thermostat works with the W5H5S24AKAAA heat pump?

The system has a 24V control circuit and supports both programmable and standard thermostats. Choose a heat pump-compatible model that can control the reversing valve and any auxiliary heat. Several options are available on this page.

Where do the condensate drains connect on the FMA5X2400AL?

Primary and secondary 3/4" FPT drain connections exit from the bottom of the cabinet, with an access panel in the bottom. This layout makes it easy to tie into an existing closet drain or a secondary safety line.

Customer Review