2.5 Ton Rheem 15.2 SEER2 R454B Central Wall Mount Apartment/Condo Type System RA14AY30AJ1NA, RF2TY3624STANSJ
This Rheem Endeavor® Line Classic® system pairs the RA14AY30AJ1NA condenser with the RF2TY3624STANSJ wall mount apartment/condo air handler, AHRI certified at 15.2 SEER2 (#215769993). The 24.5" RF2TY3624 uses a constant torque motor with two-stage airflow, and the condenser adds Rheem's quieter Swept Wing fan. It runs on low-GWP R-454B with Rheem's PlusOne® Refrigerant Detection System™. It's available with no heat or factory-installed 5, 8 or 10 kW breakered heat.
Is a 2.5 Ton Air Conditioning System the Right Size?
A 2.5 ton system provides 30,000 BTU/h of nominal cooling. It's often used in larger 2-bedroom condos and townhome-style units around 1,200–1,500 sq. ft. as a rough guide.
Ceiling height, glass area and how many exterior walls the unit has all shape the load. A Manual J load calculation gives a reliable answer.
Ideal for: Larger 2-bedroom condos and townhome-style units with a wall mount closet.
Need more capacity? Step up to the 3 Ton Rheem 15.2 SEER2 R454B Central Wall Mount Apartment/Condo Type System RA14AY36AJ1NA, RF2TY3624STANSJ, which uses the same air handler.
Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | RA14AY30AJ1NA — 2.5 Ton Rheem Classic R454B Air Conditioner |
|---|---|
| Indoor Air Handler | RF2TY3624STANSJ Wall Mount Apartment/Condo Two-Stage Air Handler (24.5" W x 36" H) |
| Application | Cooling-Only Wall Mount Apartment/Condo Split System (Factory Electric Heat Optional) |
| Refrigerant | R-454B (Low-GWP A2L Refrigerant) |
| Compressor | Single-Stage Scroll Compressor |
| Metering Device | Factory-Installed Expansion Valve on Indoor Coil (TXV) |
| Electrical | 208/230V, Single Phase, 60 Hz Condensing Unit — 17 MCA / 25A Max Overcurrent |
| Air Handler Electrical | 208/240V, Single Phase — 4 MCA / 15A Max (No Heat); Varies with Factory Heater |
The RA14AY30AJ1NA condenser is 25" tall on a 33.75" x 33.75" base and weighs 163 lbs (operating), with a 24" Swept Wing fan. The RF2TY3624STANSJ air handler measures 24.5" wide, 36" tall and 21" deep, weighs 95 lbs and uses a 20" x 25" x 1" framed filter. Complete the install with compatible thermostats and copper line sets and fittings.
Condensing Unit & Air Handler Features
RA14AY30AJ1NA Outdoor Condensing Unit
- 30,000 BTU/h nominal cooling capacity
- Single-stage scroll compressor
- 71 dBA weighted sound power rating
- 7 mm copper tube condenser coil uses less refrigerant
- 112 oz. factory R-454B charge for 15 ft. of line set
- 24" three-blade Swept Wing fan with 1/6 HP motor
- 3/8" liquid and 3/4" suction front-seating service valves
- PlusOne® Expanded Valve Space and Triple Service Access
- Composite base pan, powder-coated paint and rust-resistant screws
- 10-year conditional parts limited warranty (registration required)
RF2TY3624STANSJ Wall Mount Two-Stage Air Handler
- Compact 36" tall wall mount cabinet for apartment and condo closets
- 1/2 HP five-speed constant torque (ECM) motor with two-stage airflow
- PlusOne® Refrigerant Detection System™ with factory-installed A2L sensor
- Front or bottom return, vertical upflow installation
- Aluminum fins bonded to internally grooved aluminum tubing
- 1.0" foil-faced cabinet insulation for quieter operation
- Cabinet air leakage under 2% at 1" H₂O (ASHRAE 193)
- Continuous fan tap runs at 50% of the cooling airflow
- Durable framed cleanable 20" x 25" x 1" filter, 1,000/1,200 CFM nominal
- Factory-installed breakered heater options of none, 5, 8 or 10 kW
Specifications & Manuals
Documentation includes RA14AY electrical, sound, dimensional and line-size data, condenser installation instructions, the RA14AY brochure, RF2TY dimensions, airflow and heater tables, wall mount air handler installation instructions and the Rheem limited warranty.
Frequently Asked Questions
Why is a 3 ton wall mount air handler used with the 2.5 ton RA14AY30?
The RF2TY3624 covers 2.5 and 3 ton matches. For this 2.5 ton condenser, the installer moves it from the factory taps 4 and 5 to speed taps 2 and 3.
How deep is the RF2TY3624STANSJ?
Rheem lists it at 21" deep, 24.5" wide and 36" tall. Measure the closet depth and allow 24" in front for service.
What return air opening does the RF2TY3624 need?
Rheem lists a 23" x 21-3/8" return air opening for the 24.5" RF2TY cabinet, with front or bottom return options.
What sound rating does the RA14AY30AJ1NA have?
Rheem rates the RA14AY30 at 71 dBA weighted sound power, helped by its Swept Wing fan blade and composite base pan.
What is the maximum electric heat for the RF2TY3624?
Rheem allows up to 10 kW on the RF2TY3624, with a minimum of 976 CFM for electric heat and a maximum 44°F heat rise.
How does this compare to the 2.5 ton short apartment RB2TY system?
The RA14AY30AJ1NA, RB2TY3621STANMJB short apartment/condo system uses the same condenser and is also listed at 15.2 SEER2, with a different air handler style.


RA14AY Technical Specifications
RA14AY Installation Instructions
RA14AY Brochure
RF2TY Technical Specifications
RF2TY Installation Instructions
Rheem Warranty Certificate