2.5 Ton Rheem 15.2 SEER2 R454B Central System RA14AY30AJ1NA, RH2TY3617STANNJ
At 30,000 BTU and 15.2 SEER2, this Rheem Endeavor Line package sits in the middle of the residential range and solves a problem homeowners hit constantly: needing more than 2 tons without the wider indoor cabinet that usually comes with it. The RA14AY30AJ1NA condenser is matched to the RH2TY3617STANNJ air handler — a 36-size coil in a 17.5-inch chassis — under AHRI reference 215232493. For a retrofit where the closet is fixed and the load calculation came back at 2.5 tons, this is the combination that fits.
Is a 2.5 Ton Refrigeration System the Right Size?
Thirty thousand BTU per hour typically serves 1,200 to 1,500 square feet in a hot, humid climate. This is the size that frequently shows up on three-bedroom ranch homes, older Florida block construction with moderate insulation, and 1,300 square foot homes that have added attic insulation or impact windows since the original system was installed.
The half-ton steps matter more than people expect. A home that has been re-roofed with radiant barrier or had its ductwork sealed can legitimately drop from 3 tons to 2.5 without losing comfort, and the smaller system will hold humidity better because it runs longer cycles. Conversely, adding conditioned square footage or replacing shade trees often pushes a 2.5 ton home into 3 ton territory. Confirm with a load calculation rather than matching the old nameplate.
Ideal for: Three-bedroom ranch homes, mid-size single-story houses, well-insulated 1,400 square foot homes, and retrofits where the existing closet cannot be widened.
Need more capacity? Step up to the 3 Ton Rheem 15.2 SEER2 R454B System RA14AY36AJ1NA, RH2TY3617STANNJ, which uses this exact air handler with a larger outdoor unit.
Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, duct design, window area, ceiling height, occupancy, and local design conditions. Run our AC tonnage and BTU calculator, request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | RA14AY30AJ1NA — 2.5 Ton Endeavor Line Classic Series Air Conditioner |
|---|---|
| Indoor Air Handler | RH2TY3617STANNJ Two-Stage Multiposition Air Handler |
| Application | Residential Split System, Cool Only with Field-Installed Electric Heat |
| Refrigerant | R-454B |
| Nominal Capacity | 30,000 BTU / 2.5 Tons |
| Rated Efficiency | 15.2 SEER2 |
| Air Handler Cabinet Width | 17.5 inches |
| AHRI Reference Number | 215232493 |
| Electrical | 208-230V, Single Phase, 60 Hz |
The RH2TY3617STANNJ is the largest coil Rheem builds into the narrow 17.5-inch cabinet, and it steps the blower up to a 1/2 HP constant torque ECM motor. That extra motor capacity is what allows a 2.5 or 3 ton load to be served without moving to a 21-inch chassis. Electric heat kits, line sets, and controls are ordered separately.
Condensing Unit & Air Handler Features
RA14AY30AJ1NA Outdoor Condensing Unit
- 2.5 ton nominal capacity rated at 15.2 SEER2
- Built for low-GWP R-454B refrigerant under the 2025 EPA GWP limit
- 7mm condenser coil lowers refrigerant charge and unit weight
- PlusOne Triple Service Access with 15-inch corner service opening
- Two-fastener removable corner speeds diagnostics
- Patented one-box PlusOne Refrigerant Detection System
- Pauses outdoor operation automatically on excess refrigerant detection
- Curved louvered panels shield the coil from yard debris and impact
- Corrosion-resistant composite base pan with powder coat finish
- 10-year conditional parts warranty with Rheem registration
RH2TY3617STANNJ Air Handler
- Serves 2.5 and 3 ton applications in a 17.5-inch cabinet
- 1/2 HP constant torque ECM blower motor
- Two-stage airflow for longer, quieter dehumidification cycles
- 1.0 inch foil-faced cabinet insulation
- Aluminum fins bonded to internally grooved aluminum tubing
- Factory-installed TXV matched to R-454B operation
- 4-way convertible for upflow, downflow, and horizontal installs
- Accepts field-installed auxiliary heater kits with integral breakers
- Less than 2% cabinet air leakage at 1-inch H2O per ASHRAE 193
- Integrated A2L sensor and mitigation board
Specifications & Manuals
Product documentation includes condenser and air handler technical specifications, submittal data, installation instructions, and warranty information to assist with equipment selection, permitting, installation, and service.
Frequently Asked Questions
Why does a 2.5 ton system use a 36-size air handler?
Rheem builds the RH2TY3617STANNJ to cover both 2.5 and 3 ton applications. The 36 in the model refers to the coil family, not a fixed 3 ton output. Paired with the RA14AY30AJ1NA, the certified capacity for this combination is 2.5 tons under AHRI 215232493.
My old system was 3 tons. Can I drop to 2.5?
Often yes, particularly if the home has gained attic insulation, impact or low-E windows, a radiant barrier, or sealed ductwork since the original install. Downsizing correctly improves humidity control. Downsizing on a guess does not, so run a load calculation first.
What blower motor is in the RH2TY3617STANNJ?
It uses a 1/2 HP constant torque ECM motor, a step up from the 1/3 HP motor in the 17-size cabinet. That additional capacity is what lets the narrow 17.5-inch chassis carry 2.5 and 3 ton airflow.
Will this system dehumidify better than my old single-stage unit?
Two-stage airflow generally produces longer run times at lower speed, and longer run times remove more moisture per hour of operation than short high-speed cycles. Actual results depend on correct sizing, duct sealing, and thermostat setup.
Does the 10-year parts warranty apply automatically?
Rheem's 10-year conditional parts coverage requires product registration within the period stated on the warranty certificate linked above. Without registration, a shorter standard term applies. Register the serial numbers as soon as the system is commissioned.
What other Rheem equipment does Budget Heating carry?
Our full Rheem product catalog covers condensers, air handlers, furnaces, package units, and parts, and the complete split systems category lists every matched indoor and outdoor pairing we stock.
RA14AY Technical Specifications
Rheem Condenser Brochure
RA14AY Submittal Sheet
RH2TY Technical Specifications
RH2TY Installation Instructions
RH2TY Submittal Sheet
Rheem Warranty Certificate