2.5 Ton DiamondAir 14.3 SEER2 R32 Heat Pump System D1430HCL32A, D1430HAEAL32A
The DiamondAir 2.5 ton heat pump system pairs the D1430HCL32A outdoor unit with the D1430HAEAL32A air handler. It is rated at 27,400 BTU/h cooling and 26,400 BTU/h heating at 14.3 SEER2 with R-32 refrigerant (AHRI #218350148). It is the only size in this DiamondAir line with a DC outdoor fan motor, and its 910 CFM air handler moves more air than the smaller models. This system is aimed at homeowners and contractors serving mid-size family homes that need dependable all-electric heating and cooling.
Is a 2.5 Ton Heat Pump System the Right Size?
A 2.5 ton heat pump is one of the most common sizes for mid-size single-family homes. It works where a 2 ton system would run constantly on peak days but a 3 ton unit would cool the home too fast and leave humidity behind.
Real-world sizing should consider how well the attic and walls are insulated, the amount of west- and south-facing glass, duct size and leakage, occupancy, and local design temperatures. Hot, humid climates and homes with large windows often push the load higher, while tight, newer construction can bring it down.
Ideal for: Three-bedroom homes, ranch-style houses, larger townhomes, and small offices converted from residential space that need balanced heating and cooling.
Need more capacity? Step up to the 3 Ton DiamondAir R32 Heat Pump System D1436HCL32A, D1436HAEAL32A for homes with larger living areas or heavier summer heat gain.
Recommended sizing is a general guideline only. Actual system requirements depend on insulation, climate, ductwork, windows, occupancy, and home layout. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | D1430HCL32A — 2.5 Ton R-32 Heat Pump Condenser |
|---|---|
| Indoor Air Handler | D1430HAEAL32A Air Handler with PSC Blower |
| Application | Residential Split System Heat Pump (Heating & Cooling) |
| Refrigerant | R-32 |
| Compressor | Scroll Compressor with Crankcase Heater |
| Efficiency | 14.3 SEER2 — AHRI #218350148 |
| Electrical | 208-230V, Single Phase, 60 Hz Outdoor Unit |
| Air Handler Electrical | 208-230V, Single Phase, 60 Hz |
This matched set includes the D1430HCL32A outdoor heat pump with a 1/6 HP DC fan motor and the D1430HAEAL32A air handler with a 3/10 HP blower rated at 910 CFM. The outdoor cabinet stays at 25 inches tall and fits on a 23-5/8" square pad. Add a 5, 8, or 10 kW heat strip, an insulated copper line set, or a flush kit when you configure the system. Explore other DiamondAir products to complete your installation.
Heat Pump & Air Handler Features
D1430HCL32A Outdoor Heat Pump
- 27,400 BTU/h cooling and 26,400 BTU/h heating (rated)
- 1/6 HP DC outdoor fan motor
- Scroll compressor with crankcase heater
- Copper tube and aluminum fin coil
- 18 A minimum circuit ampacity, 30 A max overcurrent protection
- 63 dB(A) rated sound level
- 25" H x 23-5/8" W x 23-5/8" D cabinet
- 168 lb shipping weight
- 3/8" liquid, 3/4" suction line sizes
- Heats down to 5°F and cools up to 120°F outdoor ambient
D1430HAEAL32A Air Handler
- 910 CFM nominal airflow
- 3/10 HP PSC blower motor
- 11" metal centrifugal blower
- All-aluminum tube-and-fin coil
- Rated at 0.5 in. w.c. external static pressure
- 2.79 A MCA, 3 A MOP (without heat strip)
- 45-3/4" H x 19-11/16" W x 22" D
- 53 dB(A) rated sound level
- 3/4" FPT drain connection
- Heat strip ready: 5, 8, or 10 kW options
Specifications & Manuals
Product documentation includes outdoor unit and air handler technical specifications, installation manuals, heat strip installation instructions, piston replacement instructions, and DiamondAir warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
What kind of home typically uses a 2.5 ton heat pump like the D1430HCL32A?
Mid-size single-family homes, often three bedrooms, are common candidates. A load calculation is the best way to confirm 2.5 tons is right for your home and climate.
What makes the D1430HCL32A outdoor fan different from the other sizes?
The 2.5 ton D1430HCL32A uses a 1/6 HP DC fan motor, while the other sizes in this DiamondAir R-32 line use PSC fan motors, per the manufacturer's spec sheet.
How much more capacity does the 2.5 ton system offer than the 2 ton?
The D1430HCL32A is rated at 27,400 BTU/h cooling versus 22,600 for the D1424HCL32A, and its air handler moves 910 CFM compared with 820 CFM.
Will the 2.5 ton DiamondAir heat pump keep heating in cold weather?
The outdoor unit's published heating operating range extends down to 5°F outdoor temperature. In colder climates, an optional heat strip provides supplemental heat.
What kind of indoor coil does the D1430HAEAL32A use?
The air handler uses a tube-and-fin evaporator coil with aluminum tubing (9/32" tube size), according to DiamondAir's air handler specifications.
Should I flush the old line set when replacing an older system with this R-32 heat pump?
Flushing is commonly recommended when reusing existing refrigerant lines, and an RF11 one-step flush kit is offered as an option with this system. Follow the installation manual and have a qualified technician make the final call.


Click On Links Below For Documents:
DiamondAir R32 Heat Pump Condenser Technical Specifications
DiamondAir R32 SEER2 Air Handler Technical Specs
DiamondAir R32 SC, HP Condenser Installation Manual
D1418-D1460HAEAL32A R32 Air Handler Installation Manual
D1418-D1460HAEAL32A R32 Heat Strip Installation Manual
R32 Piston Replacement and Installation Instructions
DiamondAir Warranty Certificate