3 Ton DiamondAir 14.3 SEER2 R32 Heat Pump System D1436HCL32A, D1436HAEAL32A
For larger family homes, the DiamondAir 3 ton heat pump system combines the D1436HCL32A outdoor heat pump with the D1436HAEAL32A air handler in an AHRI-certified pairing (AHRI #218350149). It is rated at 32,400 BTU/h cooling and 33,000 BTU/h heating at 14.3 SEER2 with R-32 refrigerant. A wider 29-1/8" outdoor cabinet and a 1,060 CFM air handler handle the larger load, and this is the first size in the line that offers a 15 kW breakered heat strip. It's a strong choice for homeowners and contractors replacing a 3 ton system with modern R-32 equipment.
Is a 3 Ton Heat Pump System the Right Size?
The 3 ton DiamondAir heat pump is aimed at homes with an open floor plan, multiple bedrooms, and higher seasonal loads. Choosing it should come from a heating and cooling load calculation, not just the size of the system it replaces, since past systems are often oversized.
Attic insulation, window efficiency, duct design, room count, how much the home is shaded, and your local summer and winter design temperatures all change the right answer. A 3 ton system on undersized ductwork can also lose airflow, so it pays to confirm the duct system can carry about 1,060 CFM.
Ideal for: Three- to four-bedroom single-family homes, two-story homes with open layouts, and properties replacing an existing 3 ton heat pump.
Need more capacity? Step up to the 3.5 Ton DiamondAir R32 Heat Pump System D1442HCL32A, D1442HAEAL32A for homes whose calculated load exceeds what a 3 ton system can deliver.
Recommended sizing is a general guideline only. Actual system requirements depend on insulation, climate, ductwork, windows, occupancy, and home layout. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | D1436HCL32A — 3 Ton R-32 Heat Pump Condenser |
|---|---|
| Indoor Air Handler | D1436HAEAL32A Air Handler with PSC Blower |
| Application | Residential Split System Heat Pump (Heating & Cooling) |
| Refrigerant | R-32 |
| Compressor | Scroll Compressor with Crankcase Heater |
| Efficiency | 14.3 SEER2 — AHRI #218350149 |
| Electrical | 208-230V, Single Phase, 60 Hz Outdoor Unit |
| Air Handler Electrical | 208-230V, Single Phase, 60 Hz |
The D1436HCL32A outdoor unit steps up to a 29-1/8" square cabinet for more condenser coil surface, while the D1436HAEAL32A air handler keeps the 19-11/16" wide cabinet used by the smaller sizes, which helps when replacing equipment in an existing closet. Heat strip options run from 5 kW up to a 15 kW breakered kit. Compare all of our heat pump split systems to see other brands and sizes.
Heat Pump & Air Handler Features
D1436HCL32A Outdoor Heat Pump
- 32,400 BTU/h rated cooling
- 33,000 BTU/h rated heating
- Scroll compressor (13.5 RLA / 86 LRA)
- Crankcase heater standard
- Larger 29-1/8" W x 29-1/8" D cabinet, 25" tall
- 1/7 HP PSC fan motor
- 19.5 A MCA, 30 A max overcurrent protection
- Copper tube and aluminum fin coil
- 3/8" liquid and 3/4" suction connections
- 63 dB(A) rated sound level
D1436HAEAL32A Air Handler
- 1,060 CFM nominal airflow
- 3/10 HP PSC blower, 865 RPM rated
- Metal centrifugal blower wheel, 11" x 11"
- Aluminum tube-and-fin evaporator coil
- 0.5 in. w.c. external static pressure rating
- 19-11/16" wide x 45-3/4" tall cabinet
- 17-7/8" supply duct opening
- 3/4" FPT condensate drain
- 55 dB(A) rated sound level
- Heat strip options: 5, 8, 10, or 15 kW breakered
Specifications & Manuals
Product documentation includes outdoor unit and air handler technical specifications, installation manuals, heat strip installation instructions, piston replacement instructions, and DiamondAir warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
Is a 3 ton DiamondAir heat pump enough for a two-story home?
It can be, depending on the home's calculated load and duct design. Many three- to four-bedroom homes fall in the 3 ton range, but a load calculation should confirm it.
What changes when stepping up from the 2.5 ton to the 3 ton DiamondAir system?
The D1436HCL32A moves to a larger 29-1/8" square outdoor cabinet, rated cooling rises to 32,400 BTU/h, and airflow increases from 910 to 1,060 CFM.
Is a heat strip included with the 3 ton package, or is it optional?
Heat strips are optional. For this size you can choose 5, 8, or 10 kW kits, or a 15 kW breakered heat strip (WHE1502BX).
Will the D1436HAEAL32A fit in my existing air handler closet?
The air handler measures 45-3/4" H x 19-11/16" W x 22" D. Compare those dimensions to your closet and allow the service clearances shown in the installation manual.
What size condensate drain does the 3 ton air handler use?
The D1436HAEAL32A has a 3/4" FPT coil drain connection, per the manufacturer's specifications.
How much does the D1436HCL32A outdoor unit weigh for shipping?
DiamondAir lists a shipping weight of 181 lb (82.1 kg) for the 3 ton outdoor unit.


Click On Links Below For Documents:
DiamondAir R32 Heat Pump Condenser Technical Specifications
DiamondAir R32 SEER2 Air Handler Technical Specs
DiamondAir R32 SC, HP Condenser Installation Manual
D1418-D1460HAEAL32A R32 Air Handler Installation Manual
D1418-D1460HAEAL32A R32 Heat Strip Installation Manual
R32 Piston Replacement and Installation Instructions