decor decor

Summary

Product #184038: $2,345.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 46111 / 2.5 Ton DiamondAir R32 A/C Condenser, D1430ACL32A (191023) -- 1
  • 46088 / 2.5 Ton R32 DiamondAir SEER2 Air Handler, D1430HAEAL32A (202031) -- 1
2345
$2,345.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
D1430ACL32A, D1430HAEAL32A | Mid-Size R-32 Cooling with a 15-Year-Rated Refrigerant Leak Sensor

2.5 Ton DiamondAir 14.3 SEER2 R32 Central System D1430ACL32A, D1430HAEAL32A (F)

· SKU 184038 · AHRI 218350141 · Split System
SEER2
14.3
Capacity
30,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $3,166.00

Sale price:

$2,345.00
You save $821.00!
  • SKU: 184038
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.3
  • Product Type:
    Split System
  • Tonnage:
    2.5
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    19.5"
  • Manufacturer Warranty:
    5 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for DiamondAir 'D' air handlers  EHK-05 / WHE-05 WHE0502X
  • 8 KW heat strip for DiamondAir 'D' air handlers EHK-08 / WHE-08 WHE0802X
  • 10 KW heat strip for DiamondAir 'D' air handlers EHK-10 / WHE-10 WHE1002X
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • 2.5 Ton DiamondAir 14.3 SEER2 R32 A/C Condenser, D1430ACL32A (F)
  • 2.5 Ton R32 DiamondAir SEER2 Air Handler, D1430HAEAL32A
Adding to cart… The item has been added

2.5 Ton DiamondAir 14.3 SEER2 R32 Central System D1430ACL32A, D1430HAEAL32A

This DiamondAir system pairs the D1430ACL32A condenser with the D1430HAEAL32A multipoise air handler, AHRI certified at 14.3 SEER2 (#218350141). It runs on R-32, a low-GWP A2L refrigerant, and the air handler includes a factory-installed R-32 leak sensor that shuts down the compressor and electric heat if a leak is detected. It's cooling only, with optional 5, 8 or 10 kW electric heat kits.

Is a 2.5 Ton Air Conditioning System the Right Size?

A 2.5 ton system fits many 2- to 3-bedroom homes around 1,200–1,500 sq. ft. as a rough guide, though climate shifts that range a lot.

West-facing glass and vaulted ceilings can push a home toward 3 tons, while a tight, shaded home may need less. Confirm with a Manual J load calculation.

Ideal for: 2- to 3-bedroom homes, townhomes and mid-size ranch homes.

Need more capacity? Step up to the 3 Ton DiamondAir 14.3 SEER2 R32 Central System D1436ACL32A, D1436HAEAL32A for a larger load.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit D1430ACL32A — 2.5 Ton DiamondAir R32 Air Conditioner
Indoor Air Handler D1430HAEAL32A R32 Multipoise Air Handler (19-11/16" Wide)
Application Cooling-Only Central Air Split System (Electric Heat Kit Optional)
Refrigerant R-32 (Low-GWP A2L Refrigerant)
Compressor Single-Stage Scroll Compressor
Metering Device Piston (Fixed Orifice) Metering at Indoor Coil, Field Replaceable
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit — 16.7 MCA / 25A Max Overcurrent
Air Handler Electrical 208/230V, Single Phase — 2.79 MCA / 3A MOP (Blower Only, per Spec Sheet)

The D1430ACL32A condenser is 25" tall on a 23-5/8" x 23-5/8" base and ships at 148 lbs, with a 63 dB(A) sound level. The D1430HAEAL32A air handler is 45-3/4" tall, 19-11/16" wide and 22" deep and ships at 140 lbs. Complete the install with compatible thermostats and copper line sets and fittings.

Condensing Unit & Air Handler Features

D1430ACL32A Outdoor Condensing Unit

  • 27,800 BTU/h rated cooling capacity
  • Scroll compressor (11 RLA)
  • 63 dB(A) sound level
  • Copper tube and aluminum fin condenser coil
  • 1/5 HP PSC condenser fan motor
  • 3/8" liquid and 3/4" suction line connections
  • Cooling operation from 55°F to 120°F outdoor ambient
  • Operates on 187–253V, 208/230V single phase
  • Low-GWP R-32 refrigerant
  • 5-year parts limited warranty (licensed installation required)

D1430HAEAL32A R32 Multipoise Air Handler

  • Multipoise: upflow, downflow, horizontal left or right
  • Factory-installed R-32 refrigerant leak sensor
  • 3/10 HP multi-speed PSC direct drive blower motor
  • 11" x 11" metal centrifugal blower wheel
  • Aluminum tube and fin evaporator coil
  • 910 CFM nominal airflow at 0.5" external static
  • 3/4" FPT primary and auxiliary drain connections
  • 17-7/8" supply duct opening
  • External return filter required (not factory installed)
  • Field-installed electric heat kits, 5, 8 or 10 kW

Specifications & Manuals

Documentation includes DiamondAir R32 condenser and air handler specifications, condenser, air handler and heat strip installation manuals, piston replacement instructions and the DiamondAir limited warranty.

Frequently Asked Questions

How loud is the D1430ACL32A condenser?

DiamondAir lists a 63 dB(A) sound level for the 2.5 ton condenser, compared with 60 dB(A) for the 1.5 and 2 ton models.

What circuit does a 10 kW heat kit need in the D1430HAEAL32A?

DiamondAir's heat kit table lists 49.8 MCA and 50A maximum protection at 230V for the 10 kW kit, separate from the blower circuit.

What metering device does the D1430HAEAL32A use?

The indoor coil uses a piston (fixed orifice). DiamondAir provides piston replacement instructions if the installer needs to change the piston for the match.

How does this R-32 system compare to the R-410A DiamondAir 2.5 ton system?

The 2.5 ton DiamondAir R-410A system D1430ACG2, D1436HAEAL2 is the earlier version. This R-32 match uses a refrigerant with a much lower global warming potential and adds a factory-installed leak sensor in the air handler.

Is there a 2.5 ton DiamondAir R-32 heat pump system?

Yes. The 2.5 ton DiamondAir R-32 heat pump system D1430HCL32A, D1430HAEAL32A uses the same air handler and adds heating from the outdoor unit.

How long does the R-32 leak sensor last?

DiamondAir rates the refrigerant sensor for a 15-year service life and recommends blowing dust off the sensor surface after long use.

Customer Review