1.5 Ton DiamondAir 14.3 SEER2 R32 Heat Pump System D1418HCL32A, D1418HAEAL32A
The DiamondAir 1.5 ton heat pump system pairs the D1418HCL32A outdoor heat pump with the D1418HAEAL32A air handler to deliver year-round heating and cooling for compact living spaces. Rated at 14.3 SEER2 and charged with low-GWP R-32 refrigerant, this AHRI-certified match (AHRI #218350146) produces 17,000 BTU/h of cooling and 17,600 BTU/h of heating from a quiet, 25-inch-tall outdoor cabinet. It is a smart fit for homeowners, landlords, and HVAC contractors replacing aging 1.5 ton equipment in condos, apartments, small homes, and room additions.
Is a 1.5 Ton Heat Pump System the Right Size?
A 1.5 ton heat pump is the entry point of the DiamondAir R-32 split system line, and it is designed for smaller conditioned areas where a larger system would short-cycle, struggle with humidity, and waste energy. Rather than choosing by square footage alone, size this system by the actual heating and cooling load of the space it serves.
That load depends on insulation levels, window size and orientation, ceiling height, air leakage, duct condition, number of occupants, and your local climate. A well-insulated condo may need less capacity than an older cottage of the same size. Our AC tonnage and BTU calculator is a helpful starting point before you buy.
Ideal for: Condos, apartments, small single-family homes, mother-in-law suites, finished garages, and room additions that need both cooling and electric heat pump heating.
Need more capacity? Step up to the 2 Ton DiamondAir R32 Heat Pump System D1424HCL32A, D1424HAEAL32A for slightly larger homes with higher heating and cooling loads.
Recommended sizing is a general guideline only. Actual system requirements depend on insulation, climate, ductwork, windows, occupancy, and home layout. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | D1418HCL32A — 1.5 Ton R-32 Heat Pump Condenser |
|---|---|
| Indoor Air Handler | D1418HAEAL32A Air Handler with PSC Blower |
| Application | Residential Split System Heat Pump (Heating & Cooling) |
| Refrigerant | R-32 |
| Compressor | Scroll Compressor with Crankcase Heater |
| Efficiency | 14.3 SEER2 — AHRI #218350146 |
| Electrical | 208-230V, Single Phase, 60 Hz Outdoor Unit |
| Air Handler Electrical | 208-230V, Single Phase, 60 Hz |
This package gives you a factory-matched outdoor heat pump and indoor air handler designed to work together, so you do not have to guess about coil and condenser compatibility. Optional 5 kW, 8 kW, or 10 kW heat strips can be added for backup heat on colder mornings, and 25' or 50' 3/4" x 3/8" insulated copper line sets are available at checkout. Browse more DiamondAir heating and cooling equipment for matching products.
Heat Pump & Air Handler Features
D1418HCL32A Outdoor Heat Pump
- 17,000 BTU/h rated cooling and 17,600 BTU/h rated heating
- Scroll compressor for smooth, efficient operation
- Crankcase heater protects the compressor in cold weather
- Copper tube and aluminum fin outdoor coil
- Low-GWP R-32 refrigerant
- 60 dB(A) rated sound level
- Compact 25" H x 23-5/8" W x 23-5/8" D cabinet
- 3/8" liquid and 3/4" suction line connections
- Cooling operation from 55°F to 120°F outdoors
- Heating operation down to 5°F outdoors
D1418HAEAL32A Air Handler
- 820 CFM nominal airflow
- 1/5 HP PSC blower motor
- 11" x 11" metal centrifugal blower wheel
- Aluminum tube and fin evaporator coil
- Rated at 0.5 in. w.c. external static pressure
- 3/4" FPT condensate drain connection
- 17-7/8" supply duct opening
- 45-3/4" H x 19-11/16" W x 22" D cabinet
- 53 dB(A) rated sound level
- Accepts optional 5, 8, or 10 kW heat strips
Specifications & Manuals
Product documentation includes outdoor unit and air handler technical specifications, installation manuals, heat strip installation instructions, piston replacement instructions, and DiamondAir warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
What size home is the 1.5 ton D1418HCL32A system designed for?
The D1418HCL32A is built for smaller spaces such as condos, apartments, small homes, and additions. Final sizing should be based on a load calculation that accounts for insulation, windows, and your climate.
Why does a 1.5 ton system list 17,000 BTU/h of cooling instead of 18,000?
"1.5 ton" is the nominal size (18,000 BTU). The manufacturer's spec sheet lists the D1418HCL32A at a rated 17,000 BTU/h cooling and 17,600 BTU/h heating under standard test conditions.
Which heat strips can be added to the D1418HAEAL32A air handler?
This package offers optional 5 kW (WHE0502X), 8 kW (WHE0802X), and 10 kW (WHE1002X) heat strips for supplemental and emergency heat.
What refrigerant line sizes does the 1.5 ton DiamondAir heat pump use?
The D1418HCL32A connects with a 3/8" liquid line and a 3/4" suction line. Matching 25' and 50' insulated copper line sets are available as options.
How quiet is the D1418HCL32A outdoor unit?
The outdoor unit is rated at 60 dB(A), and the D1418HAEAL32A air handler is rated at 53 dB(A), per DiamondAir specifications.
Is this 1.5 ton heat pump system AHRI certified?
Yes. The D1418HCL32A and D1418HAEAL32A combination is listed under AHRI reference number 218350146 at 14.3 SEER2.


Click On Links Below For Documents:
DiamondAir R32 Heat Pump Condenser Technical Specifications
DiamondAir R32 SEER2 Air Handler Technical Specs
DiamondAir R32 SC, HP Condenser Installation Manual
D1418-D1460HAEAL32A R32 Air Handler Installation Manual
D1418-D1460HAEAL32A R32 Heat Strip Installation Manual
R32 Piston Replacement and Installation Instructions
DiamondAir Warranty Certificate