1.5 Ton DiamondAir 14.3 SEER2 R32 Central System D1418ACL32A, D1418HAEAL32A
This DiamondAir system pairs the D1418ACL32A condenser with the D1418HAEAL32A multipoise air handler, AHRI certified at 14.3 SEER2 (#218350139). It runs on R-32, a low-GWP A2L refrigerant, and the air handler includes a factory-installed R-32 leak sensor that shuts down the compressor and electric heat if a leak is detected. It's cooling only, with optional 5 or 8 kW electric heat kits.
Is a 1.5 Ton Air Conditioning System the Right Size?
A 1.5 ton system delivers 18,000 BTU/h of nominal cooling. It typically fits condos, apartments, small single-story homes and additions, roughly 600–900 sq. ft. as a loose guide.
Sun-facing windows, attic insulation and leaky ducts all change the real load. A Manual J load calculation is the reliable way to confirm 1.5 tons.
Ideal for: Condos, apartments, small single-story homes and additions on a budget.
Need more capacity? Step up to the 2 Ton DiamondAir 14.3 SEER2 R32 Central System D1424ACL32A, D1424HAEAL32A, which uses the same size air handler cabinet.
Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | D1418ACL32A — 1.5 Ton DiamondAir R32 Air Conditioner |
|---|---|
| Indoor Air Handler | D1418HAEAL32A R32 Multipoise Air Handler (19-11/16" Wide) |
| Application | Cooling-Only Central Air Split System (Electric Heat Kit Optional) |
| Refrigerant | R-32 (Low-GWP A2L Refrigerant) |
| Compressor | Single-Stage Scroll Compressor |
| Metering Device | Piston (Fixed Orifice) Metering at Indoor Coil, Field Replaceable |
| Electrical | 208/230V, Single Phase, 60 Hz Condensing Unit — 10.5 MCA / 15A Max Overcurrent |
| Air Handler Electrical | 208/230V, Single Phase — 2.25 MCA / 3A MOP (Blower Only, per Spec Sheet) |
The D1418ACL32A condenser is 25" tall on a 23-5/8" x 23-5/8" base and ships at 139 lbs, with a 60 dB(A) sound level. The D1418HAEAL32A air handler is 45-3/4" tall, 19-11/16" wide and 22" deep and ships at 131 lbs. Complete the install with compatible thermostats and copper line sets and fittings.
Condensing Unit & Air Handler Features
D1418ACL32A Outdoor Condensing Unit
- 18,000 BTU/h rated cooling capacity
- Scroll compressor (7.3 RLA)
- 60 dB(A) sound level
- Copper tube and aluminum fin condenser coil
- 1/9 HP PSC condenser fan motor
- 3/8" liquid and 3/4" suction line connections
- Cooling operation from 55°F to 120°F outdoor ambient
- Operates on 187–253V, 208/230V single phase
- Low-GWP R-32 refrigerant
- 5-year parts limited warranty (licensed installation required)
D1418HAEAL32A R32 Multipoise Air Handler
- Multipoise: upflow, downflow, horizontal left or right
- Factory-installed R-32 refrigerant leak sensor
- 1/5 HP multi-speed PSC direct drive blower motor
- 11" x 11" metal centrifugal blower wheel
- Aluminum tube and fin evaporator coil
- 820 CFM nominal airflow at 0.5" external static
- 3/4" FPT primary and auxiliary drain connections
- 17-7/8" supply duct opening
- External return filter required (not factory installed)
- Field-installed electric heat kits, 5 or 8 kW
Specifications & Manuals
Documentation includes DiamondAir R32 condenser and air handler specifications, condenser, air handler and heat strip installation manuals, piston replacement instructions and the DiamondAir limited warranty.
Frequently Asked Questions
What happens if the D1418HAEAL32A detects an R-32 leak?
The factory-installed sensor stops the compressor and shuts off the electric heater, while the blower keeps running to dilute the refrigerant. The system resumes about 5 minutes after refrigerant is no longer detected.
Does the D1418HAEAL32A come with an air filter?
No. DiamondAir states the filter is not factory installed, so an external return-air filter or filter grille is required. Don't double-filter the return or filter the supply.
How does this R-32 system compare to the R-410A DiamondAir 1.5 ton system?
The 1.5 ton DiamondAir R-410A system D1418ACG2, D1418HAEAL2 is the earlier version. This R-32 match uses a refrigerant with a much lower global warming potential and adds a factory-installed leak sensor in the air handler.
Is there a 1.5 ton DiamondAir R-32 heat pump system?
Yes. The 1.5 ton DiamondAir R-32 heat pump system D1418HCL32A, D1418HAEAL32A uses the same air handler and adds heating from the outdoor unit.
What is the largest heat kit for the 1.5 ton D1418HAEAL32A?
DiamondAir lists 5 kW and 8 kW kits for the 1.5 ton cabinet. At 230V, the 5 kW kit is rated 24.9 MCA / 25A and the 8 kW kit 37.9 MCA / 40A.
How big is the D1418ACL32A condenser?
DiamondAir lists it at 25" tall on a 23-5/8" x 23-5/8" base, with a 139 lb shipping weight.


DiamondAir R32 A/C Condenser Technical Specifications
DiamondAir R32 SEER2 Air Handler Technical Specs
DiamondAir R32 SC, HP Condenser Installation Manual
D1418-D1460HAEAL32A R32 Air Handler Installation Manual
D1418-D1460HAEAL32A R32 Heat Strip Installation Manual