5 Ton Rheem 17 SEER2 Inverter R454B Heat Pump Condenser RP17AY60AJVCA
The Rheem RP17AY60AJVCA is the largest 5-ton, top-discharge universal heat pump in the Endeavor Line Classic Plus R-454B lineup, built for the highest residential and light-commercial loads. With up to 57,000 BTU of heating at 47°F and roughly 54,000 BTU of cooling, its two-row condenser coil and inverter-driven PlusOne variable-speed compressor deliver serious capacity while still reaching up to 17 SEER2 and 9.5 HSPF2.
Is the 5 Ton RP17AY60AJVCA the Right Size?
A 5-ton heat pump serves the largest homes and many light-commercial spaces, often in the range of about 2,400 to 3,000-plus square feet, but capacity this large should never be selected on floor area alone.
Oversizing a 5-ton unit on a smaller home hurts comfort and humidity control, so a Manual J load calculation is especially important at this capacity. Where the load genuinely calls for it, the inverter-driven RP17AY60AJVCA covers peak demand while still modulating down for efficient part-load operation.
Ideal for: large single-family homes, spacious multi-story layouts, and light-commercial spaces that require maximum single-phase residential heat pump capacity.
Not sure you need a full 5 tons? Compare the 4 Ton Rheem RP17AY48AJVCA Heat Pump Condenser for larger homes with a somewhat lower cooling load.
Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, window load, and air-sealing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
Key Specifications
| Model / MPN | RP17AY60AJVCA |
|---|---|
| Nominal Capacity | 5 Tons (60,000 BTU class) |
| Rated Cooling Capacity | 54,000 BTU/h (AHRI-matched) |
| Heating Capacity | 57,000 BTU/h @ 47°F / 47,000 BTU/h @ 17°F |
| Efficiency | Up to 17 SEER2 / 11.7 EER2 / 9.5 HSPF2 |
| Refrigerant | R-454B (A2L, low GWP) |
| Compressor | Inverter-Driven PlusOne Variable-Speed Twin Rotary |
| Sound Level | As low as 57 dBA |
| Electrical | 208/230V, 1 Phase, 60 Hz • RLA 25.6 • MCA 32 • Max Fuse/HACR 50A |
| Cabinet (H x W x L) | 39" x 34" x 34" |
| Net Weight | 275 lbs |
Unlike the smaller sizes, the RP17AY60AJVCA uses a two-row condenser coil with a 23.4 square-foot face area, moving about 4,631 CFM to reject the heat this capacity demands. It ships with a factory bi-flow liquid-line filter drier and the integrated PlusOne Refrigerant Detection System, and carries the highest refrigerant charge and largest cabinet in the inverter-driven line.
Performance & Smart Control Features
RP17AY60AJVCA Performance
- Inverter-driven PlusOne variable-speed compressor for efficient part-load modulation
- Up to 57,000 BTU (47°F) heating and ~54,000 BTU cooling for maximum residential capacity
- Two-row 7mm copper condenser coil for high heat rejection
- Up to 17 SEER2 and 9.5 HSPF2 with low-GWP R-454B
- Quiet as low as 57 dBA even at full 5-ton capacity
- Brushless DC condenser motor and factory bi-flow filter drier included
Smart Control & Compatibility
- EcoNet enabled for automatic optimization with matched indoor equipment
- AHRI-matched to the 5 Ton Rheem RH2VY6024STACNJ R-454B Air Handler
- With that EcoNet-enabled air handler, install the Rheem EcoNet Smart Thermostat for communicating control
- With a non-EcoNet air handler, use the ecobee Smart Thermostat Lite (EB-STATE7P-01)
- PlusOne Diagnostics & Bluetooth for advanced setup and monitoring
- 10-year conditional parts warranty with registration
Specifications & Manuals
Product documentation includes technical specifications, installation instructions, the R-454B charge chart, and warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
How much heating capacity does the RP17AY60AJVCA produce at 47°F?
It delivers up to 57,000 BTU/h of heating at 47°F and about 47,000 BTU/h at 17°F when AHRI-matched to its indoor unit, the highest heating output in the RP17AY line.
Why does the 5-ton RP17AY use a two-row condenser coil?
The larger heat load of a 5-ton unit requires more coil surface, so this model uses a two-row coil with a 23.4 square-foot face area, where the smaller sizes use a single row.
What size breaker does the RP17AY60AJVCA need?
It has a rated-load amperage of 25.6 and a minimum circuit ampacity of 32, with a maximum fuse or HACR breaker of 50 amps. Confirm all sizing against the National Electrical Code.
Does inverter-driven operation help on a large 5-ton load?
Yes. The inverter drive lets a 5-ton unit run at reduced capacity during mild weather and ramp to full output on design days, so a large space stays comfortable without the temperature swings of a fixed-capacity condenser.
What are the cabinet dimensions and weight of the 5-ton RP17AY?
The cabinet measures 39 inches high by 34 inches wide by 34 inches deep and weighs 275 lbs net, the largest footprint in the RP17AY series.
If I need more than 5 tons, what are my options?
Loads above 5 tons generally move to three-phase commercial equipment, such as the Rheem RPCY-series 208/230V three-phase heat pump condensers, rather than a single-phase residential unit.


RP17AY Technical Specifications
RP17AY Brochure
RP17AY Charge Chart
RP17AY Submittal Sheet
RP17AY Installation Instructions
Rheem Warranty Certificate