decor decor
RP17AY60AJVCA | Maximum-Capacity Inverter Performance

5 Ton Rheem 17 SEER2 Inverter R454B Heat Pump Condenser RP17AY60AJVCA

· SKU 180251 · Condenser
SEER2
17
Capacity
60,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $6,065.00

Sale price:

$4,665.00
You save $1,400.00!
  • SKU: 180251
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • SEER2:
    17
  • Product Type:
    Condenser
  • Tonnage:
    5
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Manufacturer Warranty:
    10 Years
Adding to cart… The item has been added

5 Ton Rheem 17 SEER2 Inverter R454B Heat Pump Condenser RP17AY60AJVCA

The Rheem RP17AY60AJVCA is the largest 5-ton, top-discharge universal heat pump in the Endeavor Line Classic Plus R-454B lineup, built for the highest residential and light-commercial loads. With up to 57,000 BTU of heating at 47°F and roughly 54,000 BTU of cooling, its two-row condenser coil and inverter-driven PlusOne variable-speed compressor deliver serious capacity while still reaching up to 17 SEER2 and 9.5 HSPF2.

Is the 5 Ton RP17AY60AJVCA the Right Size?

A 5-ton heat pump serves the largest homes and many light-commercial spaces, often in the range of about 2,400 to 3,000-plus square feet, but capacity this large should never be selected on floor area alone.

Oversizing a 5-ton unit on a smaller home hurts comfort and humidity control, so a Manual J load calculation is especially important at this capacity. Where the load genuinely calls for it, the inverter-driven RP17AY60AJVCA covers peak demand while still modulating down for efficient part-load operation.

Ideal for: large single-family homes, spacious multi-story layouts, and light-commercial spaces that require maximum single-phase residential heat pump capacity.

Not sure you need a full 5 tons? Compare the 4 Ton Rheem RP17AY48AJVCA Heat Pump Condenser for larger homes with a somewhat lower cooling load.

Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, window load, and air-sealing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

Key Specifications

Model / MPN RP17AY60AJVCA
Nominal Capacity 5 Tons (60,000 BTU class)
Rated Cooling Capacity 54,000 BTU/h (AHRI-matched)
Heating Capacity 57,000 BTU/h @ 47°F / 47,000 BTU/h @ 17°F
Efficiency Up to 17 SEER2 / 11.7 EER2 / 9.5 HSPF2
Refrigerant R-454B (A2L, low GWP)
Compressor Inverter-Driven PlusOne Variable-Speed Twin Rotary
Sound Level As low as 57 dBA
Electrical 208/230V, 1 Phase, 60 Hz • RLA 25.6 • MCA 32 • Max Fuse/HACR 50A
Cabinet (H x W x L) 39" x 34" x 34"
Net Weight 275 lbs

Unlike the smaller sizes, the RP17AY60AJVCA uses a two-row condenser coil with a 23.4 square-foot face area, moving about 4,631 CFM to reject the heat this capacity demands. It ships with a factory bi-flow liquid-line filter drier and the integrated PlusOne Refrigerant Detection System, and carries the highest refrigerant charge and largest cabinet in the inverter-driven line.

Performance & Smart Control Features

RP17AY60AJVCA Performance

  • Inverter-driven PlusOne variable-speed compressor for efficient part-load modulation
  • Up to 57,000 BTU (47°F) heating and ~54,000 BTU cooling for maximum residential capacity
  • Two-row 7mm copper condenser coil for high heat rejection
  • Up to 17 SEER2 and 9.5 HSPF2 with low-GWP R-454B
  • Quiet as low as 57 dBA even at full 5-ton capacity
  • Brushless DC condenser motor and factory bi-flow filter drier included

Smart Control & Compatibility

Specifications & Manuals

Product documentation includes technical specifications, installation instructions, the R-454B charge chart, and warranty information to assist with equipment selection, installation, and service.

Frequently Asked Questions

How much heating capacity does the RP17AY60AJVCA produce at 47°F?

It delivers up to 57,000 BTU/h of heating at 47°F and about 47,000 BTU/h at 17°F when AHRI-matched to its indoor unit, the highest heating output in the RP17AY line.

Why does the 5-ton RP17AY use a two-row condenser coil?

The larger heat load of a 5-ton unit requires more coil surface, so this model uses a two-row coil with a 23.4 square-foot face area, where the smaller sizes use a single row.

What size breaker does the RP17AY60AJVCA need?

It has a rated-load amperage of 25.6 and a minimum circuit ampacity of 32, with a maximum fuse or HACR breaker of 50 amps. Confirm all sizing against the National Electrical Code.

Does inverter-driven operation help on a large 5-ton load?

Yes. The inverter drive lets a 5-ton unit run at reduced capacity during mild weather and ramp to full output on design days, so a large space stays comfortable without the temperature swings of a fixed-capacity condenser.

What are the cabinet dimensions and weight of the 5-ton RP17AY?

The cabinet measures 39 inches high by 34 inches wide by 34 inches deep and weighs 275 lbs net, the largest footprint in the RP17AY series.

If I need more than 5 tons, what are my options?

Loads above 5 tons generally move to three-phase commercial equipment, such as the Rheem RPCY-series 208/230V three-phase heat pump condensers, rather than a single-phase residential unit.

 

Customer Review