GZV7SA4810, AHVE60DP1300 | Big-Home Heat Pump Built for Real Winters

4 Ton Goodman 17.5 SEER2 R32 Side Discharge Inverter Heat Pump System GZV7SA4810, AHVE60DP1300

· SKU 180127 · AHRI 215429199 · Split System
SEER2
17.5
Capacity
48,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $8,517.00

Our price:

$7,216.00

Sale price:

$6,645.00
You save $1,872.00!

Click For Sale Price

Sale price:

$6,645.00

List price:

$8,517.00

Our price:

$7,216.00
You save: 8% ($1,872.00)
  • SKU: 180127
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    17.5
  • Product Type:
    Split System
  • Tonnage:
    4
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    24.5"
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • 20kW Breakered Heat Strip for Goodman AMST60DU1300 Air Handler 81-0631-07  HKTSD20DB
  • 25 KW breakered heat strip for Goodman ARUF, AVPTC, ARPT, ASPT, ASUF, AUPTC  HKSC-25DC / HKTSD25D1 HKTSD25DA
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 1 1/8 & 3/8
  • Copper Line Set 50' 1 1/8 & 3/8
  • Goodman GTST Connected Thermostat GTST-CW-WH-A
  • Daikin One Touch Smart Thermostat DTST-TOU-A
  • 4 Ton Goodman 17.5 SEER2 R32 Side Discharge Heat Pump Condenser GZV7SA4810
  • 5 Ton Goodman R32 Variable Speed Communicating Air Handler AHVE60DP1300
Adding to cart… The item has been added

4 Ton Goodman 17.5 SEER2 R-32 GZV7SA Side Discharge Inverter Heat Pump System

Built for larger homes in climates with real winters, the Goodman GZV7SA4810 side discharge inverter heat pump and AHVE60DP1300 communicating air handler provide 4 tons (48,000 BTU) of variable-speed comfort at an AHRI-certified 17.5 SEER2 (AHRI #215429199). The GZV7SA4810 is rated for 47,500 BTU/h of heating at 47°F and 33,600 BTU/h at 5°F, while the 1 HP AHVE60DP1300 delivers a listed 1,380 SCFM. This R-32 system gives homeowners strong cold-weather heating and quiet, efficient cooling from a side discharge outdoor unit that stays close to the house.

Is a 4 Ton GZV7SA Heat Pump the Right Size?

Four tons typically corresponds to homes of roughly 2,100 to 2,400 square feet. With a heat pump this capable in cold weather, sizing should be driven by a load calculation that weighs both the winter heating load and the summer cooling load.

Two-story layouts, bonus rooms, and extensive glass make large homes harder to size by square footage alone. The strong low-temperature output of the GZV7SA4810 can reduce how much electric backup heat a home needs, which matters for both comfort and operating cost. Ductwork should be sized for the listed 1,380 SCFM, and the 58" tall AHVE60DP1300 needs adequate mechanical space.

Ideal for: Larger single-family homes, two-story homes, colder-climate heat pump replacements, and properties where a compact side discharge outdoor unit is preferred.

Need more capacity? Step up to the 5 Ton Goodman GZV7SA6010 & AHVE60DP1300 Inverter Heat Pump System for the largest homes requiring additional heating and cooling capacity.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, windows, sun exposure, ceiling height, climate, occupancy, and ductwork. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit GZV7SA4810 — 4 Ton High-Efficiency Side Discharge Inverter Heat Pump
Indoor Air Handler AHVE60DP1300 Communicating Variable-Speed Multi-Position Air Handler with EEV
Application Split System Heat Pump, Cooling & Heating — 17.5 SEER2, AHRI #215429199
Refrigerant R-32
Compressor Inverter-Driven Variable-Speed Swing Compressor
Blower Motor 1 HP Variable-Speed ECM, 12" Blower, Constant CFM
Electrical 208-230V, Single Phase, 60 Hz Condensing Unit
Air Handler Electrical 208/230V, Single Phase, 60 Hz

The GZV7SA4810 heat pump shares the 37" W x 12-5/8" D x 39" H cabinet and 118 oz charge of the 3.5 ton model. Indoors, the AHVE60DP1300 is the largest AHVE cabinet at 24-1/2" W x 58" H. Goodman specifies a 1-1/8" suction line for this size; an insulated 50 ft 1-1/8" x 3/8" line set and a 1-1/8" to 7/8" reducer handle the connection. Pair it with the Daikin One Touch thermostat and the 5 kW HKTSN05X1 heat strip or a larger kit.

Condensing Unit & Air Handler Features

GZV7SA4810 Outdoor Heat Pump

  • 4 ton GZV7S inverter heat pump on R-32
  • 46,500 BTU/h cooling and 47,500 BTU/h heating maximum (AHRI)
  • 33,600 BTU/h heating at 5°F
  • 118 oz R-32 charge, charged for 15 ft of liquid line
  • 37.5 amp MCA, 40 amp maximum HACR breaker
  • 73 dBA cooling and heating sound rating
  • Boost mode increases compressor speed for extreme loads
  • Proprietary inside intelligence for diagnostics
  • Galvanized cabinet with grille-style sound control sides
  • ENERGY STAR Cold Climate per Goodman spec sheet

AHVE60DP1300 Communicating Air Handler

  • 1,380 SCFM listed airflow with the GZV7SA4810
  • 1 HP variable-speed ECM and 12" blower
  • 24-1/2" W x 58" H x 21" D cabinet
  • Electronic expansion valve for precise control
  • Factory R-32 sensor, UL 60335-2-40 compliant
  • Multi-position horizontal or vertical
  • Foil-faced internal insulation
  • Thermoplastic drain pan with secondary drain
  • CFM indicator for setup verification
  • Goodman 10-year parts limited warranty with registration

Specifications & Manuals

Product documentation includes GZV7S heat pump specifications, installation instructions, service and parts manuals, AHVE air handler specifications and installation instructions, and Goodman warranty certificates to assist with equipment selection, installation, and service.

Frequently Asked Questions

How large a home is the 4 ton GZV7SA4810 / AHVE60DP1300 system suited for?

Typically about 2,100 to 2,400 square feet. Because this system emphasizes heating, a load calculation that includes your winter design temperature is recommended.

What does the 4 ton GZV7SA4810 add over the 3.5 ton GZV7SA4210?

Both share the AHVE60DP1300, the same outdoor cabinet, and the same electrical ratings. The GZV7SA4810 adds capacity (46,500 vs. 41,000 BTU/h cooling and 33,600 vs. 31,000 BTU/h at 5°F), and the air handler runs at 1,380 versus 1,320 SCFM. Both systems are rated 17.5 SEER2.

How does the GZV7SA4810 heat compared with the GZV6SA4810?

Goodman rates the GZV7SA4810 at 33,600 BTU/h of heating at 5°F versus 28,000 BTU/h for the GZV6SA4810, and this system is rated 17.5 SEER2 versus 17 SEER2 for the 4 ton GZV6SA4810 system.

Can the GZV7SA4810 be wall mounted?

Goodman lists the DACA-WB-3 powder-coated wall-mounted bracket as an accessory for the 2 through 4 ton GZV7SA models, including the GZV7SA4810. Confirm structural support and clearances per the installation instructions.

Which heat kit should I add to the 4 ton GZV7SA system?

This system is offered with 5, 8, or 10 kW heat kits. The GZV7SA4810's strong low-temperature output may reduce how much backup heat is needed; size the kit to your heating load and electrical service using the AHVE heat kit data.

Who should choose the 4 ton GZV7SA inverter heat pump system?

Owners of larger homes who want strong heat pump heating in cold weather and quiet, efficient cooling in summer, plus contractors who need a compact outdoor unit. Explore more Goodman systems.

 

 

Customer Review

You Might Also Like