decor decor

Summary

Product #180267: $9,110.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 46822 / 5 Ton Goodman R32 Side Discharge Heat Pump Condenser GZV9SA6010 (180263) -- 1
  • 46589 / 5 Ton Goodman R32 Variable Speed Communicating Air Handler AHVE60DP1300 (180114) -- 1
9110
$9,110.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GZV9SA6010, AHVE60DP1300 | Maximum 5-Ton 18 SEER2 Inverter System for Big Homes

5 Ton Goodman 18 SEER2 R32 Side Discharge Inverter Heat Pump System GZV9SA6010, AHVE60DP1300

· SKU 180267 · AHRI 217989140 · Split System
SEER2
18
Capacity
60,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $12,100.00

Our price:

$9,949.00

Sale price:

$9,110.00
You save $2,990.00!

Click For Sale Price

Sale price:

$9,110.00

List price:

$12,100.00

Our price:

$9,949.00
You save: 8% ($2,990.00)
  • SKU: 180267
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    18
  • Product Type:
    Split System
  • Tonnage:
    5
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    24.5"
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • 20kW Breakered Heat Strip for Goodman AMST60DU1300 Air Handler 81-0631-07  HKTSD20DB
  • 25 KW breakered heat strip for Goodman ARUF, AVPTC, ARPT, ASPT, ASUF, AUPTC  HKSC-25DC / HKTSD25D1 HKTSD25DA
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 1 1/8 & 3/8
  • Copper Line Set 50' 1 1/8 & 3/8
  • Goodman GTST Connected Thermostat GTST-CW-WH-A
  • Daikin One Touch Smart Thermostat DTST-TOU-A
  • 5 Ton Goodman 19 SEER2 R32 Side Discharge Heat Pump Condenser GZV9SA6010
  • 5 Ton Goodman R32 Variable Speed Communicating Air Handler AHVE60DP1300
Adding to cart… The item has been added

5 Ton Goodman GZV9SA6010, AHVE60DP1300 18 SEER2 R-32 Inverter Heat Pump System

This complete, top-capacity 5-ton (60,000 BTU/h) Goodman inverter system pairs the GZV9SA6010 side-discharge condenser with the AHVE60DP1300 variable-speed communicating air handler for whole-home comfort in the largest houses. Rated 18 SEER2 on R-32 refrigerant, the matched package delivers maximum output when demand peaks and quietly scales back the rest of the time, with dependable heat-pump heating even in cold weather.

Is a 5-Ton System the Right Size?

The 5-ton GZV9SA6010 system is the maximum residential capacity in this line, reserved for large or two-story homes, sprawling single-level floor plans, and properties with high ceilings or significant heat gain. A variable-speed platform is what makes this much capacity practical: it can deliver full output on the most extreme days, then throttle down to avoid the short-cycling and uneven temperatures of oversized single-stage systems. The AHVE60DP1300 air handler provides the high airflow a system this size demands.

Capacity this large should never be chosen by square footage alone. Only a Manual J load calculation weighing insulation, window area, duct capacity, ceiling height, and climate can confirm a 5-ton system is genuinely required rather than oversized.

Ideal for: large or two-story homes, expansive open floor plans, and high-load properties needing maximum whole-home capacity.

Not sure you need this much? Step down to the 4 Ton GZV9SA4810 + AHVE60DP1300 system for larger-but-not-maximum loads.

Recommended applications are general guidelines only. Confirm that maximum capacity is warranted with our tonnage & BTU calculator, request free sizing help, or call 813-885-7999.

What's Included

Outdoor Condensing Unit GZV9SA6010 — 5 Ton Variable-Speed Inverter Heat Pump, Side Discharge
Indoor Air Handler AHVE60DP1300 — Variable-Speed ECM Communicating Air Handler with Internal EEV
System Type R-32 Side-Discharge Inverter Heat Pump Split System
Nominal Capacity 5 Ton — 60,000 BTU/h
Efficiency 18 SEER2 / up to 9.0 HSPF2 (variable-speed inverter)
Refrigerant R-32
Compressor Variable-Speed Inverter-Driven Swing Compressor
Heating Operation Reliable heating down to -20°F
Electrical 208-230V / 1 Phase / 60 Hz (dedicated circuits; size per rating plates)
Recommended Thermostat Daikin One Touch DTST-TOU-A (upgrade over the standard Goodman GTST-CW-WH-A)
Warranty 10-Year Parts Limited Warranty & 10-Year Unit Replacement Limited Warranty (with timely registration)

Sold as an AHRI-matched R-32 pairing, the GZV9SA6010 and AHVE60DP1300 are built to deliver maximum residential capacity together. A 3kW–25kW field-installed electric heat kit is available for supplemental or backup heat.

System Features

GZV9SA6010 Outdoor Condenser

  • Top-of-line 60,000 BTU/h inverter output for the largest homes
  • Peak capacity paired with quiet, efficient part-load operation
  • 18 SEER2 / up to 9.0 HSPF2 efficiency across the seasons
  • Dependable cold-weather heat-pump heating down to -20°F
  • Slim side-discharge cabinet places maximum capacity in a compact footprint
  • R-32 refrigerant with factory-installed stop valves
  • Heavy-gauge galvanized steel cabinet with corrosion-resistant finish

AHVE60DP1300 Indoor Air Handler

  • High-output variable-speed ECM blower matched to 5-ton airflow needs
  • Constant CFM over a wide static-pressure range for balanced delivery
  • Internal EEV for precise refrigerant metering
  • All-aluminum evaporator coil optimized for R-32
  • Factory-installed A2L leak sensor for the life of the coil
  • Multi-position install with slim 21" depth for attic access
  • Communicating controls with CFM indicator and 6-fault recall

Recommended Thermostat: Daikin One Touch

To get the most from this top-capacity system, we recommend the Daikin One Touch Smart Thermostat (DTST-TOU-A) — a nicer, more capable control that works better with the inverter equipment than the standard option. The Goodman GTST Connected Thermostat (GTST-CW-WH-A) is available as the standard choice.

Specifications & Manuals

Documentation covers both the outdoor condenser and indoor air handler, including technical specifications, installation instructions, and service information for selection, installation, and maintenance.

Frequently Asked Questions

Is the 5-ton GZV9SA6010 system large enough for a big or two-story home?

The 5-ton is the maximum capacity in the GZV9S line and is intended for large or two-story homes and high-load properties. Confirm the requirement with a Manual J calculation so the system is not oversized.

How does this 5-ton system differ from the 4-ton version?

Both use the same AHVE60DP1300 air handler and inverter platform, but the 5-ton GZV9SA6010 condenser delivers a higher 60,000 BTU/h output for the largest homes, while the 4-ton is sized for large-but-not-maximum loads.

Why does a variable-speed 5-ton stay efficient at such a large capacity?

Rather than running at full power and cycling off, the inverter compressor and variable-speed blower operate at lower speeds during partial loads, which keeps the 18 SEER2 / up to 9.0 HSPF2 efficiency working for you most of the time.

Does the system include a refrigerant leak sensor for R-32?

Yes. The AHVE60DP1300 air handler has a factory-installed A2L refrigerant sensor designed to last the life of the coil, providing built-in safety monitoring for the R-32 charge.

Which thermostat is best for this top-capacity system?

We recommend the Daikin One Touch DTST-TOU-A over the standard Goodman GTST-CW-WH-A — it is the nicer control and works better with the inverter system, which is especially valuable on a large, long-cycling installation.

 

 
 


 

Customer Review

You Might Also Like