GZV6SA6010, AHVE60DP1300 | Flagship 5-Ton Inverter Heating & Cooling, Compact Outside

5 Ton Goodman 16.6 SEER2 R32 Side Discharge Inverter Heat Pump System GZV6SA6010, AHVE60DP1300

· SKU 180122 · AHRI 215429195 · Split System
SEER2
16.6
Capacity
60,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $7,810.00

Our price:

$7,209.00

Sale price:

$6,040.00
You save $1,770.00!

Click For Sale Price

Sale price:

$6,040.00

List price:

$7,810.00

Our price:

$7,209.00
You save: 16% ($1,770.00)
  • SKU: 180122
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    16.6
  • Product Type:
    Split System
  • Tonnage:
    5
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    24.5"
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • 20kW Breakered Heat Strip for Goodman AMST60DU1300 Air Handler 81-0631-07  HKTSD20DB
  • 25 KW breakered heat strip for Goodman ARUF, AVPTC, ARPT, ASPT, ASUF, AUPTC  HKSC-25DC / HKTSD25D1 HKTSD25DA
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 1 1/8 & 3/8
  • Copper Line Set 50' 1 1/8 & 3/8
  • Goodman GTST Connected Thermostat GTST-CW-WH-A
  • Daikin One Touch Smart Thermostat DTST-TOU-A
  • 5 Ton Goodman 16.2 SEER2 R32 Side Discharge Heat Pump Condenser GZV6SA6010
  • 5 Ton Goodman R32 Variable Speed Communicating Air Handler AHVE60DP1300
Adding to cart… The item has been added

5 Ton Goodman 16.6 SEER2 R-32 Side Discharge Inverter Heat Pump System

The flagship of this Goodman lineup, the GZV6SA6010 side discharge inverter heat pump and AHVE60DP1300 communicating air handler deliver 5 tons (60,000 BTU) of variable-speed heating and cooling at an AHRI-certified 16.6 SEER2 (AHRI #215429195). With up to 54,500 BTU/h of heating at 47°F, 33,000 BTU/h at 5°F, a 118 oz R-32 charge, and a 1 HP variable-speed blower moving a rated 1,640 SCFM, it is built for large homes that want inverter comfort without a massive top-discharge condenser in the yard. Homeowners and contractors get Goodman's 10-year unit replacement limited warranty with registration and a compact, wall-friendly outdoor cabinet.

Is a 5 Ton Inverter Heat Pump the Right Size?

Five tons is typically reserved for homes in the neighborhood of 2,400 to 3,000 square feet, or smaller homes with very high heat gain. As the largest size in the GZV6SA line, it deserves a careful Manual J calculation covering both heating and cooling, since many homes that "feel" like a 5 ton job turn out to need less.

Large homes often have multiple stories, cathedral ceilings, extensive glass, and long duct runs, all of which affect both load and airflow. The AHVE60DP1300 holds its rated 1,640 SCFM up to 0.9" w.c. external static, but ductwork still needs to be sized for that volume to stay quiet. The inverter compressor turns down on mild days, which helps a 5 ton system maintain comfort and humidity between peak conditions.

Ideal for: Large single-family homes, two-story homes with open floor plans, homes replacing 5 ton single-stage heat pumps, and properties that need maximum capacity from a compact side discharge outdoor unit.

Need more capacity? The 5 ton GZV6SA6010 is the largest model in this side discharge inverter series. For loads above 5 tons, request free sizing assistance and we will recommend a multi-system or zoned solution.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, windows, sun exposure, ceiling height, climate, occupancy, and ductwork. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit GZV6SA6010 — 5 Ton Side Discharge Inverter Heat Pump
Indoor Air Handler AHVE60DP1300 Communicating Variable-Speed Multi-Position Air Handler with EEV
Application Split System Heat Pump, Cooling & Heating — 16.6 SEER2, AHRI #215429195
Refrigerant R-32
Compressor Inverter-Driven Variable-Speed Swing Compressor
Blower Motor 1 HP Variable-Speed ECM, 12" Blower, Constant CFM
Electrical 208-230V, Single Phase, 60 Hz Condensing Unit
Air Handler Electrical 208/230V, Single Phase, 60 Hz

The GZV6SA6010 heat pump weighs 179 lb in a 37" W x 12-5/8" D x 39" H cabinet. The AHVE60DP1300 air handler is the largest in the AHVE family at 24-1/2" W x 58" H with a 1 HP motor. Goodman specifies a 1-1/8" suction line for 5 tons, so an insulated 50 ft 1-1/8" x 3/8" copper line set with a 7/8" adapter at the outdoor valve is typical. Control everything with the Goodman GTST connected thermostat.

Condensing Unit & Air Handler Features

GZV6SA6010 Outdoor Heat Pump

  • Largest GZV6SA model: 53,500 BTU/h cooling, 54,500 BTU/h heating (AHRI)
  • 33,000 BTU/h heating at 5°F
  • Variable-speed swing compressor with high-density sound blanket
  • 118 oz R-32 factory charge; 9°F ±1°F subcooling target
  • 37.5 MCA with 40 amp maximum overcurrent protection
  • Quiet 0.36 HP DC fan motor with digital commutation
  • 73 dBA normal-mode sound rating per AHRI 270
  • 1/2" or 3/4" electrical conduit size
  • Seven-segment LED diagnostics with fault code storage
  • 500-hour salt-spray tested ZAM base frame

AHVE60DP1300 Communicating Air Handler

  • 1 HP variable-speed ECM, the most powerful in the AHVE line
  • 1,640 SCFM rated airflow with the GZV6SA6010
  • 24-1/2" W x 58" H x 21" D cabinet, 167 lb ship weight
  • EEV metering and factory-installed R-32 sensor
  • All-aluminum coil built with 7mm tubing
  • Rigid SmartFrame cabinet with leather grain-embossed finish
  • Cabinet leakage under 1.4% at 0.5" H2O
  • CFM indicator and six-fault memory
  • Installs vertically or horizontally
  • Supports 5, 8, or 10 kW electric heat kits

Specifications & Manuals

Product documentation includes GZV6S heat pump specifications, installation instructions, service and parts manuals, AHVE air handler specifications and installation instructions, and Goodman warranty certificates to assist with equipment selection, installation, and service.

Frequently Asked Questions

How large a home can the 5 ton GZV6SA6010 system serve?

Typically around 2,400 to 3,000 square feet, depending on insulation, windows, and climate. Because 5 tons is the top of the line, a careful heating and cooling load calculation is strongly recommended.

What does the 5 ton system add over the 4 ton GZV6SA4810?

The GZV6SA6010 adds capacity (53,500 vs. 45,500 BTU/h cooling and 33,000 vs. 28,000 BTU/h heating at 5°F), a 118 oz charge, and a 40 amp breaker. Indoors, the AHVE60DP1300 steps up to a 1 HP motor and 1,640 SCFM. The system is rated 16.6 SEER2.

What size breaker does the GZV6SA6010 need?

Goodman lists a 37.5 amp minimum circuit ampacity and a 40 amp maximum time-delay fuse or HACR-type breaker on 208-230V single phase, with a 197 to 253 volt operating range. Always check the unit rating plate.

Is the 5 ton GZV6SA6010 loud?

Its normal-mode sound rating is 73 dBA in both cooling and heating. Quiet mode offers reduced sound levels with lower capacity, and the compressor sound blanket helps dampen noise. Place it away from bedrooms and patios when possible.

Does R-32 change how the 5 ton system is installed?

R-32 is an A2L refrigerant, so the AHVE60DP1300 includes a factory-installed R-32 sensor and installers must follow A2L procedures. The unit is charged for 15 ft of 3/8" liquid line; longer runs need charge adjustment. Learn more in our refrigerant transition guide and SEER2 guide.

Who chooses the top-capacity 5 ton side discharge inverter heat pump?

Owners of large homes who want variable-speed comfort and strong cold-weather heating from a compact outdoor unit, and contractors replacing 5 ton systems on tight lots or in coastal, hurricane-prone areas.

 

 