decor decor

Summary

Product #179359: $4,310.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 41904 / 4 Ton Rheem R454B Two Stage Heat Pump Condenser RP14AY48AJ2NA (179272) -- 1
  • 41941 / 4 Ton Rheem Two Stage R454B Air Handler RH2TY4821STANNJ (179309) -- 1
4310
$4,310.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
RP14AY48AJ2NA, RH2TY4821STANNJ | Workhorse Capacity for Large Homes and Small Commercial

4 Ton Rheem 14.3 SEER2 R454B Two Stage Heat Pump System RP14AY48AJ2NA, RH2TY4821STANNJ

· SKU 179359 · AHRI 214568778 · Split System
SEER2
14.3
Capacity
48,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,256.00

Sale price:

$4,310.00
You save $946.00!
  • SKU: 179359
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.3
  • Product Type:
    Split System
  • Tonnage:
    4
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    21"
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • 15 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RH1PY, RH2TY, RH2VY, RXBH-1724A15J-1, WRX1502BI
  • 20 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724A20J-1, WRX2002BI
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • Honeywell T6 Pro Thermostat 3H/2C Programmable TH6320U2008
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Honeywell T10 Pro Smart Wi-Fi Touchsrceen Thermostat 3H/2C Programmable w/ Sensor, THX321WFS2001W
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 4 Ton Rheem 14.3 SEER2 R454B Two Stage Heat Pump Condenser RP14AY48AJ2NA
  • 4 Ton Rheem Two Stage R454B Air Handler RH2TY4821STANNJ
Adding to cart… The item has been added

4 Ton Rheem 14.3 SEER2 R-454B Two Stage Heat Pump System RP14AY48AJ2NA, RH2TY4821STANNJ

Forty-eight thousand BTU of two-stage capacity, built for larger single-system homes. The RP14AY48AJ2NA outdoor heat pump drives the RH2TY4821STANNJ air handler at the top of that cabinet's rating, delivering full four-ton output on R-454B refrigerant with a 27 amp minimum circuit ampacity. For builders and contractors working 2,000 to 2,400 square foot plans, this is the workhorse size of the Endeavor Line Classic Series.

Is a 4 Ton Heat Pump System the Right Size?

Four tons covers approximately 1,900 to 2,400 square feet in a hot climate. Larger four and five bedroom homes, houses with a lot of glass, and open-plan layouts with two-story great rooms commonly land here. It is also a common capacity for light commercial spaces such as offices, salons and small retail suites.

At this capacity, distribution becomes the deciding factor. A 4 ton system moves around 1,600 CFM, and a home that fights to deliver that airflow will feel uneven no matter how the equipment is rated. Long duct runs, a single undersized return, and closed interior doors all raise static pressure. If one part of the house is consistently warmer, zoning or a second smaller system is often a better answer than simply adding tonnage.

Ideal for: Four and five bedroom homes, open-plan houses with two-story great rooms, homes with extensive glass, and light commercial offices or retail suites in the 1,900 to 2,400 square foot range.

Need more capacity? Step up to the 5 Ton Rheem RP14AY60AJ2NA, RH2TY6024STANNJ Heat Pump System at 15.2 SEER2, or the narrower-cabinet 5 Ton RP14AY60AJ2NA, RH2TY6021STANAJ system when closet width is limited.

Recommended capacity ranges are general guidelines only. Actual system requirements depend on insulation, window area, duct design, air infiltration, and local climate. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump RP14AY48AJ2NA — 4 Ton / 48,000 BTU Two-Stage Heat Pump
Indoor Air Handler RH2TY4821STANNJ — 21.5 in. Wide Multiposition Air Handler
Application Residential and Light Commercial Split System Heat Pump
Refrigerant R-454B Low GWP (A2L)
Compressor Two-Stage Scroll
Rated Efficiency 14.3 SEER2 / 9.0 EER2 / 7.5 HSPF2 (Region IV)
AHRI Reference 214568778
Condenser Electrical 208/230V, Single Phase, 60 Hz — 27 MCA / 45 A Max Fuse or Breaker
Air Handler Electrical 208/240V, Single Phase, 60 Hz
Line Set Connections 3/8 in. Liquid, 7/8 in. Vapor

This match tops out the RH2TY4821STANNJ cabinet, so there is no headroom left indoors for a future capacity increase without changing air handlers. Plan the electrical accordingly, since the 45 amp maximum breaker is a step above the 3.5 ton system, and size auxiliary heat with a kit such as the 19.2 kW Rheem RXBH heat strip only after confirming fit and circuit capacity in the RH2TY tables.

Condenser & Air Handler Features

RP14AY48AJ2NA Outdoor Heat Pump

  • 48,000 BTU two-stage scroll compressor for large-home and light commercial loads
  • Two discrete capacity steps reduce on-off cycling on partial-load days
  • Inverted reversing valve with gravity-assist shifting for durable defrost operation
  • Expanded valve space and 15 in. corner access speed up charging and service calls
  • Individual louver panels can be removed for coil cleaning without full teardown
  • PlusOne Refrigerant Detection System combines the A2L sensor and mitigation board
  • Automatic outdoor unit shutdown if refrigerant is detected above threshold
  • Standard 24V control interface works with conventional two-stage heat pump thermostats
  • R-454B refrigerant delivers a 78 percent GWP reduction over previous generation refrigerants
  • 27 amp minimum circuit ampacity with 45 amp maximum overcurrent protection

RH2TY4821STANNJ Air Handler

  • 21.5 in. cabinet operating at the top of its 3.5 to 4 ton rating
  • 3/4 HP constant-torque ECM blower sized for approximately 1,600 CFM
  • Two-stage airflow profile follows compressor staging for quieter part-load operation
  • 7/8 in. vapor and 3/8 in. liquid sweat connections match the larger outdoor unit
  • Field-installed heat kits to 18.0 kW at 208V or 24.0 kW at 240V
  • Breakered heat kits satisfy UL and cUL service disconnect requirements
  • Upflow, downflow, horizontal left and horizontal right installation from one cabinet
  • Aluminum A-coil construction throughout for corrosion resistance
  • Foil-faced 1.0 in. insulation with verified sub-2 percent cabinet leakage
  • Onboard A2L detection shares the same architecture as the outdoor unit

Specifications & Manuals

Specification and submittal documents for both the RP14AY outdoor unit and the RH2TY air handler are provided, along with installation instructions, the product brochure, and Rheem warranty terms. On commercial and permitted jobs, the submittal sheets carry the dimensional, weight and electrical data most inspectors and general contractors ask for.

Frequently Asked Questions

How many square feet will a 4 ton Rheem heat pump condition?

Typically 1,900 to 2,400 square feet in the Southeast, and more in a milder climate or a tightly built home. Ceiling height and glass area move that number substantially, so a load calculation is the only way to be certain.

Do the 3.5 ton and 4 ton systems use the same air handler?

Yes, both use the RH2TY4821STANNJ. The 3.5 ton RP14AY42AJ2NA system sits at the bottom of that cabinet's range and this one sits at the top, so the outdoor unit and circuit sizing are the practical differences.

What is the minimum circuit ampacity for the RP14AY48AJ2NA?

27 amps, with a 45 amp maximum fuse or circuit breaker on 208/230V single phase power. That is a step up from the 3.5 ton unit, so an existing 40 amp circuit may need to be re-evaluated on a replacement job.

Can a 4 ton heat pump work in a light commercial space?

It is frequently used that way in offices, salons and small retail suites. Commercial loads often carry higher occupancy and equipment heat gain than a house of the same size, so the load calculation should reflect actual use rather than floor area alone.

Does this system include a thermostat?

No, the thermostat is ordered separately. Any 24V control with two-stage compressor and auxiliary heat terminals will run it, from a basic programmable unit to a smart Wi-Fi model. Browse the complete systems category for matched accessories.

What warranty coverage applies to the RP14AY48AJ2NA?

Rheem publishes conditional parts coverage of up to ten years when the equipment is registered within the required period after installation; unregistered equipment receives the shorter standard term. The exact terms, exclusions and registration deadline are in the Rheem warranty document linked above.

Customer Review

You Might Also Like