decor decor

Summary

Product #184039: $2,555.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 46112 / 3 Ton DiamondAir 14.3 SEER2 R32 A/C Condenser, D1436ACL32A (F) (191024) -- 1
  • 46089 / 3 Ton R32 DiamondAir SEER2 Air Handler, D1436HAEAL32A (202032) -- 1
2555
$2,555.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
D1436ACL32A, D1436HAEAL32A | Dependable 3 Ton R-32 Cooling with Heat Kit Options Up to 15 kW

3 Ton DiamondAir 14.3 SEER2 R32 Central System D1436ACL32A, D1436HAEAL32A (F)

· SKU 184039 · AHRI 218350142 · Split System
SEER2
14.3
Capacity
36,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $3,449.00

Sale price:

$2,555.00
You save $894.00!
  • SKU: 184039
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.3
  • Product Type:
    Split System
  • Tonnage:
    3
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    19.5"
  • Manufacturer Warranty:
    5 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for DiamondAir 'D' air handlers  EHK-05 / WHE-05 WHE0502X
  • 8 KW heat strip for DiamondAir 'D' air handlers EHK-08 / WHE-08 WHE0802X
  • 10 KW heat strip for DiamondAir 'D' air handlers EHK-10 / WHE-10 WHE1002X
  • 15 KW breakered heat strip for DiamondAir 'D' air handlers EHK-15B / WHE1502BX
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • 3 Ton DiamondAir 14.3 SEER2 R32 A/C Condenser, D1436ACL32A (F)
  • 3 Ton R32 DiamondAir SEER2 Air Handler, D1436HAEAL32A
Adding to cart… The item has been added

3 Ton DiamondAir 14.3 SEER2 R32 Central System D1436ACL32A, D1436HAEAL32A

This DiamondAir system pairs the D1436ACL32A condenser with the D1436HAEAL32A multipoise air handler, AHRI certified at 14.3 SEER2 (#218350142). It runs on R-32, a low-GWP A2L refrigerant, and the air handler includes a factory-installed R-32 leak sensor that shuts down the compressor and electric heat if a leak is detected. It's cooling only, with electric heat kits from 5 kW up to 15 kW available.

Is a 3 Ton Air Conditioning System the Right Size?

A 3 ton system is often used in 3-bedroom homes around 1,500–1,800 sq. ft. as a general guide. Hot, humid climates may need more capacity.

Return air and duct sizing matter as much as the equipment at this size. Pair a Manual J load calculation with a duct check.

Ideal for: 3-bedroom single-family homes and larger townhomes.

Need more capacity? Step up to the 3.5 Ton DiamondAir 14.3 SEER2 R32 Central System D1442ACL32A, D1442HAEAL32A for a larger load.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit D1436ACL32A — 3 Ton DiamondAir R32 Air Conditioner
Indoor Air Handler D1436HAEAL32A R32 Multipoise Air Handler (19-11/16" Wide)
Application Cooling-Only Central Air Split System (Electric Heat Kit Optional)
Refrigerant R-32 (Low-GWP A2L Refrigerant)
Compressor Single-Stage Scroll Compressor
Metering Device Piston (Fixed Orifice) Metering at Indoor Coil, Field Replaceable
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit — 19.5 MCA / 30A Max Overcurrent
Air Handler Electrical 208/230V, Single Phase — 2.79 MCA / 3A MOP (Blower Only, per Spec Sheet)

The D1436ACL32A condenser is 25" tall on a 29-1/8" x 29-1/8" base and ships at 160 lbs, with a 63 dB(A) sound level. The D1436HAEAL32A air handler is 45-3/4" tall, 19-11/16" wide and 22" deep and ships at 140 lbs. Complete the install with compatible thermostats and copper line sets and fittings.

Condensing Unit & Air Handler Features

D1436ACL32A Outdoor Condensing Unit

  • 33,000 BTU/h rated cooling capacity
  • Scroll compressor (13.5 RLA)
  • 63 dB(A) sound level
  • Copper tube and aluminum fin condenser coil
  • 1/7 HP PSC condenser fan motor
  • 3/8" liquid and 3/4" suction line connections
  • Cooling operation from 55°F to 120°F outdoor ambient
  • Operates on 187–253V, 208/230V single phase
  • Low-GWP R-32 refrigerant
  • 5-year parts limited warranty (licensed installation required)

D1436HAEAL32A R32 Multipoise Air Handler

  • Multipoise: upflow, downflow, horizontal left or right
  • Factory-installed R-32 refrigerant leak sensor
  • 3/10 HP multi-speed PSC direct drive blower motor
  • 11" x 11" metal centrifugal blower wheel
  • Aluminum tube and fin evaporator coil
  • 1,060 CFM nominal airflow at 0.5" external static
  • 3/4" FPT primary and auxiliary drain connections
  • 17-7/8" supply duct opening
  • External return filter required (not factory installed)
  • Field-installed electric heat kits, 5 kW up to 15 kW

Specifications & Manuals

Documentation includes DiamondAir R32 condenser and air handler specifications, condenser, air handler and heat strip installation manuals, piston replacement instructions and the DiamondAir limited warranty.

Frequently Asked Questions

How is a 15 kW heat kit wired in the D1436HAEAL32A?

The 15 kW kit uses two circuits. DiamondAir lists circuit 1 at 37.9 MCA / 40A and circuit 2 at 24.9 MCA / 25A at 230V.

How big is the 3 ton D1436ACL32A condenser?

DiamondAir lists it at 25" tall on a wider 29-1/8" x 29-1/8" base, with a 160 lb shipping weight.

Is there a minimum room size for this R-32 system?

Yes. Because R-32 is an A2L refrigerant, the installation manual sets a required minimum conditioned area based on the total system refrigerant charge. Your installer calculates it from the manual's tables.

How does this R-32 system compare to the R-410A DiamondAir 3 ton system?

The 3 ton DiamondAir R-410A system D1436ACL2, D1436HAEAL2 is the earlier version. This R-32 match uses a refrigerant with a much lower global warming potential and adds a factory-installed leak sensor in the air handler.

Is there a 3 ton DiamondAir R-32 heat pump system?

Yes. The 3 ton DiamondAir R-32 heat pump system D1436HCL32A, D1436HAEAL32A uses the same air handler and adds heating from the outdoor unit.

What outdoor temperatures can the D1436ACL32A cool in?

DiamondAir lists a cooling operating range of 55°F to 120°F outdoor ambient.