Rheem OEM High Pressure Switch — 42-105499-08
The Rheem 42-105499-08 is a genuine OEM high-pressure cutout switch that protects an air conditioner or heat pump from dangerously high refrigerant discharge pressure. Wired into the control circuit on the high side, it opens and shuts the compressor off if pressure climbs too high — from a dirty condenser, a failed condenser fan, overcharge, or blocked airflow — preventing compressor and system damage. This is the correct OEM pressure control for compatible Rheem/Ruud equipment.
Will This Pressure Switch Fit Your Unit?
The 42-105499-08 is a Rheem/Ruud OEM high-pressure switch specified on many Rheem and Ruud condensers and heat pumps. Pressure switches are matched to specific trip and reset set-points and fittings, so confirm the part number printed on your existing switch before ordering.
To replace it, recover or isolate pressure as required, disconnect power, remove the old switch from its port or line, and install the new one with proper sealing. A tripped high-pressure switch is a symptom — correct the underlying high-head-pressure condition before returning the unit to service.
Fits: Rheem/Ruud air conditioners and heat pumps that use high-pressure switch 42-105499-08.
Replacing the compressor? See a Copeland scroll compressor and matching parts if high-pressure trips damaged it.
Replacement parts are application-specific. Confirm the exact part number and your unit's model and serial number before ordering. Need help confirming fitment? Request free assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Part Number | 42-105499-08 |
|---|---|
| Product Type | Refrigerant High-Pressure Cutout Switch |
| Brand | Rheem / Ruud |
| Function | Opens the control circuit on excessive refrigerant discharge pressure |
| Mounting | Refrigerant line/service port |
| Condition | Genuine OEM |
A genuine OEM Rheem safety switch for the refrigerant high side. Confirm the part number against your existing switch before ordering, or contact us for help identifying the correct pressure control for your unit.
Part Details
Switch & Function
- Genuine Rheem/Ruud OEM high-pressure switch (42-105499-08)
- Opens the control circuit when discharge pressure gets too high
- Protects the compressor from high-pressure damage
- Automatically or manually resets once pressure returns to normal
- Correct OEM refrigerant-side safety control for compatible units
Condition & Installation
- Genuine OEM — not aftermarket
- Confirm 42-105499-08 against your existing switch
- Match trip/reset set-points by using the OEM part
- Correct the high-pressure cause before resetting
- Refrigerant-side service — for a qualified technician
Specifications & Manuals
Genuine Rheem/Ruud OEM high-pressure switch (42-105499-08). A high-pressure trip points to a refrigerant-side problem — dirty condenser coil, failed condenser fan, overcharge, or restricted airflow. Diagnose and correct the cause before returning the system to service, and confirm the part number before ordering.
Frequently Asked Questions
What does the 42-105499-08 switch do?
It is a refrigerant high-pressure safety that opens the control circuit if discharge pressure climbs too high, shutting down the compressor to prevent damage.
What causes a high-pressure trip?
A dirty or blocked condenser coil, a failed condenser fan motor, refrigerant overcharge, or restricted condenser airflow.
Is it genuine Rheem?
Yes, it is a genuine Rheem/Ruud OEM high-pressure switch, not aftermarket.
Where is it located?
On the refrigerant high side, typically on the liquid/discharge line or a service port of the outdoor unit.
Does it reset itself?
Depends on the configuration; many high-pressure switches reset automatically once pressure normalizes, but the underlying cause must still be fixed. Confirm your unit's switch type.