Rheem / Ruud Furnace Manual Reset Limit Switch — 47-104888-01 (L250F)
Protect a Rheem or Ruud furnace from overheating with this genuine OEM 47-104888-01 manual-reset limit switch (L250F). It is a high-limit safety that senses excessive temperature — usually caused by lost airflow — and opens near 250°F to cut the burner, requiring a manual reset so a technician can address the root cause. Installing the correct OEM limit keeps the furnace's safety chain intact and the heat exchanger protected.
Does This Switch Match Your Unit?
This is the Rheem/Ruud OEM L250F manual-reset limit, part 47-104888-01, used across many Rheem and Ruud gas furnaces and gas packaged units. Open temperature and reset type must match the original, so verify the number on your existing switch or your unit's parts list before ordering.
To install, disconnect power, transfer the wiring to the new switch, and mount it in the original position. Remember that a tripped high-limit is a symptom, not the disease — correct the restricted airflow, dirty filter, or blower fault that caused the overheat before resetting.
Fits: Rheem and Ruud gas furnaces and packaged gas units that use limit switch 47-104888-01 (L250F, 250°F manual reset).
Also chasing a safety trip? On packaged units, see the Rheem 42-105499-08 high-pressure switch for the refrigerant side.
Replacement parts are application-specific. Confirm the exact part number and your unit's model and serial number before ordering. Need help confirming fitment? Request free assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Part Number | 47-104888-01 |
|---|---|
| Product Type | Manual Reset Limit / Rollout Switch |
| Brand | Rheem / Ruud |
| Rating | L250F (opens at ~250°F) |
| Reset | Manual reset button |
| Condition | Genuine OEM |
A genuine OEM Rheem/Ruud safety switch. Confirm the part number on your existing switch before ordering, or contact us for help identifying the correct limit for your furnace.
Part Details
Switch & Function
- Genuine Rheem/Ruud OEM manual-reset limit switch (47-104888-01)
- Opens the gas/heat circuit at approximately 250°F (L250F)
- Protects against overheating from restricted airflow or a failed blower
- Manual reset button requires a technician to clear the fault
- Correct OEM safety control for compatible Rheem/Ruud furnaces
Fitment & Safety
- Genuine Rheem/Ruud OEM part, not aftermarket
- L250F open temperature with manual reset
- Verify 47-104888-01 against your existing switch
- Mount in the original orientation and location
- Always fix the overheat cause before returning to service
Specifications & Manuals
Genuine Rheem/Ruud OEM manual-reset limit switch (47-104888-01, L250F). A tripped manual-reset limit indicates an overheating condition — find and correct the cause (airflow, blower, duct restriction) before resetting. Confirm the part number against your unit before ordering.
Frequently Asked Questions
What does the 47-104888-01 limit switch do?
It is a manual-reset high-limit safety switch (L250F) that shuts off the furnace if it overheats — typically around 250°F — to prevent heat-exchanger and fire damage.
Why is it manual reset?
A manual-reset limit forces a technician to investigate and clear the fault after an overheat, rather than letting the furnace cycle on a dangerous condition.
What makes a limit switch trip?
Restricted airflow — a dirty filter, closed registers, a failed blower motor, or blocked ducts. Fix the cause before resetting.
Is it a genuine Rheem/Ruud part?
Yes, it is a genuine OEM safety switch, not aftermarket.
Is this the same as the other 47-104888-01 listing?
Yes, it is the same genuine OEM L250F manual-reset limit switch. Confirm the part number against your unit before ordering.