Rheem OEM High Pressure Switch — 42-105499-08
Keep your Rheem or Ruud system protected with this genuine OEM 42-105499-08 high-pressure switch. It is a refrigerant high-side safety that monitors compressor discharge pressure and opens the control circuit to stop the compressor if pressure rises to an unsafe level. High-pressure trips are usually caused by condenser airflow or charge problems, and this OEM switch restores the system's protection after the original has failed or weakened.
Does This Switch Match Your System?
This is the Rheem/Ruud OEM high-pressure switch, part 42-105499-08, used across a range of Rheem and Ruud air conditioners and heat pumps. Because the trip/reset pressures and fitting must match, verify the part number on your existing switch or your unit's parts list before ordering.
Installation is a refrigerant-side repair: relieve pressure as required, disconnect power, swap the switch at its port or line with proper sealing, and leak-check. Always diagnose why the high-pressure switch tripped — clean the condenser, confirm the condenser fan runs, and verify the charge — before putting the system back in service.
Fits: Rheem/Ruud air conditioners and heat pumps that use high-pressure switch 42-105499-08.
Replacing the compressor? See a Copeland scroll compressor and matching parts if high-pressure trips damaged it.
Replacement parts are application-specific. Confirm the exact part number and your unit's model and serial number before ordering. Need help confirming fitment? Request free assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Part Number | 42-105499-08 |
|---|---|
| Product Type | Refrigerant High-Pressure Cutout Switch |
| Brand | Rheem / Ruud |
| Function | Opens the control circuit on excessive refrigerant discharge pressure |
| Mounting | Refrigerant line/service port |
| Condition | Genuine OEM |
A genuine OEM Rheem safety switch for the refrigerant high side. Confirm the part number against your existing switch before ordering, or contact us for help identifying the correct pressure control for your unit.
Part Details
Switch & Function
- Genuine Rheem/Ruud OEM high-pressure switch (42-105499-08)
- Opens the control circuit when discharge pressure gets too high
- Protects the compressor from high-pressure damage
- Automatically or manually resets once pressure returns to normal
- Correct OEM refrigerant-side safety control for compatible units
Fitment & Service
- Genuine Rheem/Ruud OEM part, not aftermarket
- Verify 42-105499-08 against your existing switch
- Matches the unit's trip and reset set-points
- Install with proper sealing and leak-check
- Fix the high-head-pressure cause before resetting
Specifications & Manuals
Genuine Rheem/Ruud OEM high-pressure switch (42-105499-08). A high-pressure trip points to a refrigerant-side problem — dirty condenser coil, failed condenser fan, overcharge, or restricted airflow. Diagnose and correct the cause before returning the system to service, and confirm the part number before ordering.
Frequently Asked Questions
What does the 42-105499-08 switch do?
It is a refrigerant high-pressure safety that opens the control circuit if discharge pressure climbs too high, shutting down the compressor to prevent damage.
What causes a high-pressure trip?
A dirty or blocked condenser coil, a failed condenser fan motor, refrigerant overcharge, or restricted condenser airflow.
Is it genuine Rheem?
Yes, it is a genuine Rheem/Ruud OEM high-pressure switch, not aftermarket.
Where is it located?
On the refrigerant high side, typically on the liquid/discharge line or a service port of the outdoor unit.
Is this the same as the other 42-105499-08 listing?
Yes, it is the same genuine OEM Rheem high-pressure switch. Confirm the part number against your unit before ordering.