Rheem / Ruud Furnace Manual Reset Limit Switch — 47-104888-01 (L250F)
The Rheem/Ruud 47-104888-01 is a genuine OEM manual-reset limit switch (L250F) that protects a gas furnace or packaged gas unit from overheating. If airflow is lost — a clogged filter, failed blower, or blocked duct — the switch opens at about 250°F to shut down the burner and must be manually reset, preventing heat-exchanger damage and unsafe operation. This is the correct OEM safety control for compatible Rheem and Ruud equipment.
Will This Limit Switch Fit Your Furnace?
The 47-104888-01 is a Rheem/Ruud OEM limit switch rated L250F (opens near 250°F) with a manual reset button. It is specified on a range of Rheem and Ruud gas furnaces and packaged gas units. Because limit switches are matched to a specific open temperature and mounting, confirm the part number printed on your existing switch before ordering.
Replacement is quick: disconnect power, note the wiring, remove the mounting screws, and install the new switch in the same orientation. Critically, a limit that has tripped means the unit overheated — find and fix the airflow problem before returning the system to service.
Fits: Rheem and Ruud gas furnaces and packaged gas units that use limit switch 47-104888-01 (L250F, 250°F manual reset).
Also chasing a safety trip? On packaged units, see the Rheem 42-105499-08 high-pressure switch for the refrigerant side.
Replacement parts are application-specific. Confirm the exact part number and your unit's model and serial number before ordering. Need help confirming fitment? Request free assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Part Number | 47-104888-01 |
|---|---|
| Product Type | Manual Reset Limit / Rollout Switch |
| Brand | Rheem / Ruud |
| Rating | L250F (opens at ~250°F) |
| Reset | Manual reset button |
| Condition | Genuine OEM |
A genuine OEM Rheem/Ruud safety switch. Confirm the part number on your existing switch before ordering, or contact us for help identifying the correct limit for your furnace.
Part Details
Switch & Function
- Genuine Rheem/Ruud OEM manual-reset limit switch (47-104888-01)
- Opens the gas/heat circuit at approximately 250°F (L250F)
- Protects against overheating from restricted airflow or a failed blower
- Manual reset button requires a technician to clear the fault
- Correct OEM safety control for compatible Rheem/Ruud furnaces
Condition & Installation
- Genuine OEM — not aftermarket
- Confirm the number on your existing switch (47-104888-01)
- Replace in the same location and orientation
- Investigate the overheat cause before resetting/returning to service
- Install with power disconnected; for a qualified technician
Specifications & Manuals
Genuine Rheem/Ruud OEM manual-reset limit switch (47-104888-01, L250F). A tripped manual-reset limit indicates an overheating condition — find and correct the cause (airflow, blower, duct restriction) before resetting. Confirm the part number against your unit before ordering.
Frequently Asked Questions
What does the 47-104888-01 limit switch do?
It is a manual-reset high-limit safety switch (L250F) that shuts off the furnace if it overheats — typically around 250°F — to prevent heat-exchanger and fire damage.
Why is it manual reset?
A manual-reset limit forces a technician to investigate and clear the fault after an overheat, rather than letting the furnace cycle on a dangerous condition.
What makes a limit switch trip?
Restricted airflow — a dirty filter, closed registers, a failed blower motor, or blocked ducts. Fix the cause before resetting.
Is it a genuine Rheem/Ruud part?
Yes, it is a genuine OEM safety switch, not aftermarket.
Can I just keep resetting it?
No. Repeated trips mean a real overheating problem. Diagnose and fix the airflow or blower issue; continually resetting a safety switch is dangerous.