decor decor

Rheem/Ruud Furnace Manual Reset Limit Switch, 47-104888-01 (F)

  • SKU: D-5726-1

Discontinued

Rheem / Ruud Furnace Manual Reset Limit Switch — 47-104888-01 (L250F)

The Rheem/Ruud 47-104888-01 is a genuine OEM manual-reset limit switch (L250F) that protects a gas furnace or packaged gas unit from overheating. If airflow is lost — a clogged filter, failed blower, or blocked duct — the switch opens at about 250°F to shut down the burner and must be manually reset, preventing heat-exchanger damage and unsafe operation. This is the correct OEM safety control for compatible Rheem and Ruud equipment.

Will This Limit Switch Fit Your Furnace?

The 47-104888-01 is a Rheem/Ruud OEM limit switch rated L250F (opens near 250°F) with a manual reset button. It is specified on a range of Rheem and Ruud gas furnaces and packaged gas units. Because limit switches are matched to a specific open temperature and mounting, confirm the part number printed on your existing switch before ordering.

Replacement is quick: disconnect power, note the wiring, remove the mounting screws, and install the new switch in the same orientation. Critically, a limit that has tripped means the unit overheated — find and fix the airflow problem before returning the system to service.

Fits: Rheem and Ruud gas furnaces and packaged gas units that use limit switch 47-104888-01 (L250F, 250°F manual reset).

Also chasing a safety trip? On packaged units, see the Rheem 42-105499-08 high-pressure switch for the refrigerant side.

Replacement parts are application-specific. Confirm the exact part number and your unit's model and serial number before ordering. Need help confirming fitment? Request free assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Part Number 47-104888-01
Product Type Manual Reset Limit / Rollout Switch
Brand Rheem / Ruud
Rating L250F (opens at ~250°F)
Reset Manual reset button
Condition Genuine OEM

A genuine OEM Rheem/Ruud safety switch. Confirm the part number on your existing switch before ordering, or contact us for help identifying the correct limit for your furnace.

Part Details

Switch & Function

  • Genuine Rheem/Ruud OEM manual-reset limit switch (47-104888-01)
  • Opens the gas/heat circuit at approximately 250°F (L250F)
  • Protects against overheating from restricted airflow or a failed blower
  • Manual reset button requires a technician to clear the fault
  • Correct OEM safety control for compatible Rheem/Ruud furnaces

Condition & Installation

  • Genuine OEM — not aftermarket
  • Confirm the number on your existing switch (47-104888-01)
  • Replace in the same location and orientation
  • Investigate the overheat cause before resetting/returning to service
  • Install with power disconnected; for a qualified technician

Specifications & Manuals

Genuine Rheem/Ruud OEM manual-reset limit switch (47-104888-01, L250F). A tripped manual-reset limit indicates an overheating condition — find and correct the cause (airflow, blower, duct restriction) before resetting. Confirm the part number against your unit before ordering.

Frequently Asked Questions

What does the 47-104888-01 limit switch do?

It is a manual-reset high-limit safety switch (L250F) that shuts off the furnace if it overheats — typically around 250°F — to prevent heat-exchanger and fire damage.

Why is it manual reset?

A manual-reset limit forces a technician to investigate and clear the fault after an overheat, rather than letting the furnace cycle on a dangerous condition.

What makes a limit switch trip?

Restricted airflow — a dirty filter, closed registers, a failed blower motor, or blocked ducts. Fix the cause before resetting.

Is it a genuine Rheem/Ruud part?

Yes, it is a genuine OEM safety switch, not aftermarket.

Can I just keep resetting it?

No. Repeated trips mean a real overheating problem. Diagnose and fix the airflow or blower issue; continually resetting a safety switch is dangerous.

Customer Review