5 Ton Goodman 16.2 SEER2 R32 Two Stage Central System GLXT7CA6010, AMVT60DP1300 Variable Speed
The largest system in Goodman's premium GLXT7 line pairs the 60,000 BTU/h GLXT7CA6010 two-stage condenser with the D-cabinet AMVT60DP1300 variable-speed air handler (AHRI #215865329, 16.2 SEER2). It's built for very large homes and single-phase light commercial spaces. The package combines full 5 ton capacity with communicating controls, a two-speed ECM outdoor fan, a factory crankcase heater and a 1 HP variable-speed blower that moves up to 2,000 CFM on high stage. It's cooling only, with support for heat kits up to 25 kW.
Is a 5 Ton Air Conditioning System the Right Size?
At 60,000 BTU/h, 5 tons is the largest single-phase residential size. It's typically considered for large homes, often 2,500–3,000 sq. ft. or more as a rough reference, or for small offices and retail spaces with high loads. Two-stage operation gives this size useful flexibility, running on low stage during milder weather instead of cycling at full capacity.
Confirm the load with a Manual J or commercial load calculation. Verify the ductwork can carry 2,000 CFM on high stage and that the electrical panel can support a 60A-max condenser circuit plus the air handler and any heat kit. Very large or multi-level homes sometimes do better with two zoned systems, and our team can help you compare.
Ideal for: Large custom homes, high-ceiling two-story homes and single-phase light commercial spaces that want premium two-stage, variable-speed comfort.
Need heating too? See the 5 Ton Goodman 16.2 SEER2 R32 Two Stage Heat Pump System GLZT7CA6010, AMVT60DP1300 for heating and cooling from one outdoor unit.
Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | GLXT7CA6010 — 5 Ton Two-Stage R32 Split System Air Conditioner |
|---|---|
| Indoor Air Handler | AMVT60DP1300 Variable-Speed ECM Air Handler (D Cabinet, 24.5" Wide) |
| Application | Two-Stage Communicating Cooling-Only Split System (Electric Heat Kit Optional) |
| Refrigerant | R-32 |
| Compressor | Copeland Ultra-Tech Two-Stage Scroll Compressor with Factory Crankcase Heater |
| Metering Device | Factory-Installed Internal Thermal Expansion Valve (TXV) |
| Electrical | 208/230V, Single Phase, 60 Hz Condensing Unit — 36.4 MCA / 60A Max Overcurrent |
| Air Handler Electrical | 208/240V, Single Phase — 8.6 MCA / 15A Max Overcurrent (No Heat Kit) |
The GLXT7CA6010 condenser measures 35-1/2" x 35-1/2" x 41-5/8" and weighs 283 lbs, with a 167 oz. factory R-32 charge and a 75 dBA sound rating. The AMVT60DP1300 air handler uses the 24.5" D cabinet (58" tall, 24-5/8" deep). Its 1 HP variable-speed motor drives an 11" x 10" blower wheel, delivering 1,340 CFM on low stage and 2,000 CFM on high stage. It's rated at the same 16.2 SEER2 as the 5 ton GLXS5 system. The GLXT7 package stands apart with variable-speed airflow, ComfortBridge™ communicating controls and a Lifetime Compressor Limited Warranty with registration.
Condensing Unit & Air Handler Features
GLXT7CA6010 Outdoor Condensing Unit
- 60,000 BTU/h nominal cooling, the top capacity in the GLXT7 line
- Copeland Ultra-Tech two-stage scroll compressor
- Factory-installed crankcase heater
- Quiet two-speed 1/3 HP ECM outdoor fan motor
- 75 dBA rated sound level
- 167 oz. factory R-32 charge for 15 ft. of tubing
- 1-1/8" suction line recommended (7/8" service valve; adapter field supplied)
- ComfortBridge™ communicating with CoolCloud™ Bluetooth diagnostics
- Compatible with CSR-U-3 hard-start and OT18-60A outdoor thermostat accessories
- Baked-on powder paint with 500-hour salt-spray approval
AMVT60DP1300 Variable-Speed Air Handler
- 1 HP variable-speed ECM blower with 11" x 10" wheel
- 1,340 / 2,000 CFM low/high airflow with a 5 ton condenser
- Adjustable low CFM for efficient fan-only operation
- Internal factory-installed TXV
- 24.5" D cabinet, 58" tall and 24-5/8" deep
- Upflow or horizontal, with a DFKE-03 downflow kit available
- Compatible with the 0230K00007 R-32 zoning accessory kit
- Optional HHK0007 high humidity kit and UVPK07 UV drain pan kit
- Tool-less 23" x 20" filter access
- Accepts HKTS electric heat kits from 5 kW up to 25 kW
Specifications & Manuals
Documentation includes GLXT7CA6010 electrical, refrigerant and wiring data, AMVT60DP1300 D-cabinet dimensions, airflow tables and heat kit data up to 25 kW, installation instructions and warranty terms.
Frequently Asked Questions
Why is the 5 ton GLXT7 rated 16.2 SEER2 when the smaller sizes are 17.2?
The GLXT7CA6010 and AMVT60DP1300 combination is AHRI certified at 16.2 SEER2 (#215865329). Goodman's "up to 17.2 SEER2" rating for the series applies to the smaller matched systems.
What do I get over the 5 ton GLXS5 if both are rated 16.2 SEER2?
The GLXT7 package adds a variable-speed AMVT air handler, ComfortBridge™ communicating controls, a two-speed ECM outdoor fan, Copeland ComfortAlert™ diagnostics and a Lifetime Compressor Limited Warranty with registration.
What airflow range does the AMVT60DP1300 cover?
With a 5 ton outdoor unit, Goodman lists 1,340 CFM on low stage and 2,000 CFM on high stage. Your ductwork should be designed to carry the high-stage airflow.
Can the AMVT60DP1300 be used in a zoned system?
Goodman lists the 0230K00007 R-32 zoning accessory kit for all AMVT models. Zoning design and controls should be planned by your installer.
Is there a heat pump version of this 5 ton two-stage system?
Yes. The 5 ton Goodman GLZT7CA6010 two-stage R32 heat pump system pairs with the same AMVT60DP1300 air handler.
Can the AMVT60DP1300 run a low-speed fan-only mode?
Yes. The AMVT air handler provides an adjustable low CFM setting for efficient continuous fan-only operation, which helps circulate and filter air between cooling cycles.
Click On Links Below For Specifications & Documents:
AMVT R32 Technical Specifications
Goodman Seer2 Air Handler Warranty Certificate
GLXT7C Technical Specifications
Goodman R32 Condenser Installation Manual
"SEER2"stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).