3 Ton Goodman 17.2 SEER2 R32 Two Stage Central System GLXT7CA3610, AMVT36CP1300 Variable Speed
This package brings Goodman's premium two-stage technology to the most popular residential size. It pairs the GLXT7CA3610 two-stage R-32 condenser with the AMVT36CP1300 variable-speed air handler, AHRI certified at 17.2 SEER2 (#215865742). Mid-size homes get long, quiet low-stage cycles on mild days and full 36,000 BTU/h capacity on the hottest afternoons. The variable-speed blower is designed for improved humidity and comfort control. It's a strong pick for homeowners replacing a 3 ton system who want the quietest, most refined comfort in the R-32 lineup. It's cooling only, with optional field-installed electric heat.
Is a 3 Ton Air Conditioning System the Right Size?
Three tons (36,000 BTU/h) fits many mid-size homes. That's often around 1,500–1,800 sq. ft. as a loose benchmark, and it's the most common size in existing homes. With a two-stage system, the right tonnage matters even more. Low stage handles most of the season, so the high-stage capacity should match your hottest design days.
Look at attic insulation, window area and orientation, duct leakage and how humid the home gets in summer. Homes that struggle with humidity under a single-stage system often benefit most from two-stage operation and variable-speed airflow, provided the system isn't oversized.
Ideal for: Mid-size 3–4 bedroom homes, humid-climate homes and 3 ton replacements where owners want premium comfort and quiet operation.
Need more capacity? Step up to the 4 Ton Goodman 17.2 SEER2 R32 Two Stage Central System GLXT7CA4810, AMVT48CP1300 for larger homes.
Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | GLXT7CA3610 — 3 Ton Two-Stage R32 Split System Air Conditioner |
|---|---|
| Indoor Air Handler | AMVT36CP1300 Variable-Speed ECM Air Handler (C Cabinet, 21" Wide) |
| Application | Two-Stage Communicating Cooling-Only Split System (Electric Heat Kit Optional) |
| Refrigerant | R-32 |
| Compressor | Copeland Ultra-Tech Two-Stage Scroll Compressor |
| Metering Device | Factory-Installed Internal Thermal Expansion Valve (TXV) |
| Electrical | 208/230V, Single Phase, 60 Hz Condensing Unit — 20.8 MCA / 35A Max Overcurrent |
| Air Handler Electrical | 208/240V, Single Phase — 6.5 MCA / 15A Max Overcurrent (No Heat Kit) |
The GLXT7CA3610 condenser measures 35-1/2" x 35-1/2" x 39-1/2" and weighs 216 lbs, with a 92 oz. factory R-32 charge and a 70 dBA sound rating. Goodman lists a 7/8" suction line with a 3/4" suction valve, and any adapter is field supplied. The AMVT36CP1300 air handler is 49" tall in the 21" C cabinet with a 3/4 HP variable-speed motor. It provides 804 CFM on low stage and 1,200 CFM on high stage. Browse more options in our variable-speed air handlers category, or compare with the 3 ton GLXS5 single-stage system.
Condensing Unit & Air Handler Features
GLXT7CA3610 Outdoor Condensing Unit
- 36,000 BTU/h nominal cooling capacity
- Copeland Ultra-Tech two-stage scroll compressor
- Quiet two-speed 1/3 HP ECM outdoor fan motor
- 70 dBA rated sound level
- ComfortBridge™ communicating technology with CoolCloud™ Bluetooth setup
- Copeland® ComfortAlert™ built-in diagnostics
- Color-coded terminal strip for non-communicating setups
- Ambient temperature sensors and factory-installed transformer
- High-density foam compressor sound blanket
- Heavy-gauge galvanized steel cabinet with rust-resistant screws
AMVT36CP1300 Variable-Speed Air Handler
- 3/4 HP variable-speed ECM blower with 10" x 8" wheel
- 804 / 1,200 CFM low/high airflow with a 3 ton condenser
- Improved humidity and comfort control
- Built-in compatibility with multi-stage cooling
- Internal factory-installed TXV
- 21" C cabinet, 49" tall with 21-1/8" depth
- Upflow or horizontal, with a DFKE-02 downflow kit available
- Optional HHK0005 high humidity kit and UVPK03 UV drain pan kit
- Tool-less 19.5" x 20" filter access
- Accepts HKTS electric heat kits from 3 kW up to 19 kW
Specifications & Manuals
Documentation covers GLXT7CA3610 specifications, expanded cooling and wiring data, AMVT36CP1300 airflow, dimensions and heat kit tables, installation procedures and warranty terms.
Frequently Asked Questions
What are the low and high airflow settings of the AMVT36CP1300 on a 3 ton?
Goodman's airflow data lists 804 CFM on low stage and 1,200 CFM on high stage when paired with a 3 ton outdoor unit.
Why does the GLXT7CA3610 need a suction line adapter?
Goodman specifies a 7/8" suction line for a 25 ft. line set, but the unit's suction service valve is 3/4". Any adapter must be supplied in the field.
How does a two-stage compressor help with humidity?
On low stage, the system runs longer, gentler cycles instead of short blasts at full capacity. That gives the coil more time to remove moisture, and the AMVT's variable-speed blower is designed for improved humidity and comfort control.
What diagnostics are built into this 3 ton system?
The GLXT7CA3610 includes Copeland® ComfortAlert™ diagnostics and Bluetooth access through the CoolCloud™ app. The AMVT36CP1300 adds a CFM indicator and recall of the six most recent faults.
What warranty covers the GLXT7CA3610 compressor?
With online registration within 60 days of installation, Goodman offers a Lifetime Compressor Limited Warranty (for as long as you own your home), a 10-Year Unit Replacement Limited Warranty and a 10-Year Parts Limited Warranty. Registration isn't required in Florida, California or Québec.
Can I use a conventional non-communicating thermostat?
Yes. The GLXT7CA3610 has a color-coded terminal strip for non-communicating setups. Communicating mode unlocks ComfortBridge™ features such as automatic airflow and tonnage configuration.
Click On Links Below For Specifications & Documents:
AMVT R32 Technical Specifications
Goodman Seer2 Air Handler Warranty Certificate
GLXT7C Technical Specifications
Goodman R32 Condenser Installation Manual
"SEER2"stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).