Summary

Product #179552: $5,125.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Indoor Air Quality:
  • Thermostats:
  • 45494 / 3 Ton Goodman Two Stage R32 A/C Condenser GLXT7CA3610 (179548) -- 1
  • 45380 / 3 Ton Goodman R32 Variable Speed Air Handler AMVT36CP1300 (179528) -- 1
5125
$5,125.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLXT7CA3610, AMVT36CP1300 | Two-Stage, Variable-Speed Humidity Control for the Classic 3 Ton Home

3 Ton Goodman 17.2 SEER2 R32 Two Stage Central System GLXT7CA3610, AMVT36CP1300 Variable Speed

· SKU 179552 · AHRI 215865742 · Split System
SEER2
17.2
Capacity
36,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $6,519.00

Our price:

$5,847.00

Sale price:

$5,125.00
You save $1,394.00!

Click For Sale Price

Sale price:

$5,125.00

List price:

$6,519.00

Our price:

$5,847.00
You save: 12% ($1,394.00)
  • SKU: 179552
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    17.2
  • Product Type:
    Split System
  • Tonnage:
    3
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    21"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • Clean Comfort 1" Electronic Cleaner 19.5x20 model AE10-1920-14
  • Clean Comfort Electronic Air Cleaner model AE14-2020-51
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 3 Ton Goodman 17.2 SEER2 Two Stage R32 A/C Condenser GLXT7CA3610
  • 3 Ton Goodman R32 Variable Speed Air Handler AMVT36CP1300
Adding to cart… The item has been added

3 Ton Goodman 17.2 SEER2 R32 Two Stage Central System GLXT7CA3610, AMVT36CP1300 Variable Speed

This package brings Goodman's premium two-stage technology to the most popular residential size. It pairs the GLXT7CA3610 two-stage R-32 condenser with the AMVT36CP1300 variable-speed air handler, AHRI certified at 17.2 SEER2 (#215865742). Mid-size homes get long, quiet low-stage cycles on mild days and full 36,000 BTU/h capacity on the hottest afternoons. The variable-speed blower is designed for improved humidity and comfort control. It's a strong pick for homeowners replacing a 3 ton system who want the quietest, most refined comfort in the R-32 lineup. It's cooling only, with optional field-installed electric heat.

Is a 3 Ton Air Conditioning System the Right Size?

Three tons (36,000 BTU/h) fits many mid-size homes. That's often around 1,500–1,800 sq. ft. as a loose benchmark, and it's the most common size in existing homes. With a two-stage system, the right tonnage matters even more. Low stage handles most of the season, so the high-stage capacity should match your hottest design days.

Look at attic insulation, window area and orientation, duct leakage and how humid the home gets in summer. Homes that struggle with humidity under a single-stage system often benefit most from two-stage operation and variable-speed airflow, provided the system isn't oversized.

Ideal for: Mid-size 3–4 bedroom homes, humid-climate homes and 3 ton replacements where owners want premium comfort and quiet operation.

Need more capacity? Step up to the 4 Ton Goodman 17.2 SEER2 R32 Two Stage Central System GLXT7CA4810, AMVT48CP1300 for larger homes.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit GLXT7CA3610 — 3 Ton Two-Stage R32 Split System Air Conditioner
Indoor Air Handler AMVT36CP1300 Variable-Speed ECM Air Handler (C Cabinet, 21" Wide)
Application Two-Stage Communicating Cooling-Only Split System (Electric Heat Kit Optional)
Refrigerant R-32
Compressor Copeland Ultra-Tech Two-Stage Scroll Compressor
Metering Device Factory-Installed Internal Thermal Expansion Valve (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit — 20.8 MCA / 35A Max Overcurrent
Air Handler Electrical 208/240V, Single Phase — 6.5 MCA / 15A Max Overcurrent (No Heat Kit)

The GLXT7CA3610 condenser measures 35-1/2" x 35-1/2" x 39-1/2" and weighs 216 lbs, with a 92 oz. factory R-32 charge and a 70 dBA sound rating. Goodman lists a 7/8" suction line with a 3/4" suction valve, and any adapter is field supplied. The AMVT36CP1300 air handler is 49" tall in the 21" C cabinet with a 3/4 HP variable-speed motor. It provides 804 CFM on low stage and 1,200 CFM on high stage. Browse more options in our variable-speed air handlers category, or compare with the 3 ton GLXS5 single-stage system.

Condensing Unit & Air Handler Features

GLXT7CA3610 Outdoor Condensing Unit

  • 36,000 BTU/h nominal cooling capacity
  • Copeland Ultra-Tech two-stage scroll compressor
  • Quiet two-speed 1/3 HP ECM outdoor fan motor
  • 70 dBA rated sound level
  • ComfortBridge™ communicating technology with CoolCloud™ Bluetooth setup
  • Copeland® ComfortAlert™ built-in diagnostics
  • Color-coded terminal strip for non-communicating setups
  • Ambient temperature sensors and factory-installed transformer
  • High-density foam compressor sound blanket
  • Heavy-gauge galvanized steel cabinet with rust-resistant screws

AMVT36CP1300 Variable-Speed Air Handler

  • 3/4 HP variable-speed ECM blower with 10" x 8" wheel
  • 804 / 1,200 CFM low/high airflow with a 3 ton condenser
  • Improved humidity and comfort control
  • Built-in compatibility with multi-stage cooling
  • Internal factory-installed TXV
  • 21" C cabinet, 49" tall with 21-1/8" depth
  • Upflow or horizontal, with a DFKE-02 downflow kit available
  • Optional HHK0005 high humidity kit and UVPK03 UV drain pan kit
  • Tool-less 19.5" x 20" filter access
  • Accepts HKTS electric heat kits from 3 kW up to 19 kW

Specifications & Manuals

Documentation covers GLXT7CA3610 specifications, expanded cooling and wiring data, AMVT36CP1300 airflow, dimensions and heat kit tables, installation procedures and warranty terms.

Frequently Asked Questions

What are the low and high airflow settings of the AMVT36CP1300 on a 3 ton?

Goodman's airflow data lists 804 CFM on low stage and 1,200 CFM on high stage when paired with a 3 ton outdoor unit.

Why does the GLXT7CA3610 need a suction line adapter?

Goodman specifies a 7/8" suction line for a 25 ft. line set, but the unit's suction service valve is 3/4". Any adapter must be supplied in the field.

How does a two-stage compressor help with humidity?

On low stage, the system runs longer, gentler cycles instead of short blasts at full capacity. That gives the coil more time to remove moisture, and the AMVT's variable-speed blower is designed for improved humidity and comfort control.

What diagnostics are built into this 3 ton system?

The GLXT7CA3610 includes Copeland® ComfortAlert™ diagnostics and Bluetooth access through the CoolCloud™ app. The AMVT36CP1300 adds a CFM indicator and recall of the six most recent faults.

What warranty covers the GLXT7CA3610 compressor?

With online registration within 60 days of installation, Goodman offers a Lifetime Compressor Limited Warranty (for as long as you own your home), a 10-Year Unit Replacement Limited Warranty and a 10-Year Parts Limited Warranty. Registration isn't required in Florida, California or Québec.

Can I use a conventional non-communicating thermostat?

Yes. The GLXT7CA3610 has a color-coded terminal strip for non-communicating setups. Communicating mode unlocks ComfortBridge™ features such as automatic airflow and tonnage configuration.

Click On Links Below For Specifications & Documents:

Technical SpecificationsAMVT R32 Technical Specifications
Technical SpecificationsGoodman Seer2 Air Handler Warranty Certificate
GLXT7C Technical Specifications
Goodman R32 Condenser Installation Manual

 

SEER2 Explained

"SEER2"stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).
3 Ton Goodman 17.2 SEER2 R32 Two Stage Central System GLXT7CA3610, AMVT36CP1300 Variable Speed