5 Ton EcoTemp 14.5 SEER2 R-454B Heat Pump System – W5H5S60AKAAA & WCHL605BD
The EcoTemp W5H5S60AKAAA and WCHL605BD are the top of this R-454B heat pump line. They deliver 60,000 BTU/h of heating and cooling at 14.5 SEER2 for the largest residential loads. The outdoor unit has its own larger 35" cabinet. The two-piece modular WCHL605BD air handler moves 1,750 CFM nominal and can be carried in sections into attics and crawlspaces.
Is a 5 Ton Heat Pump System the Right Size?
Five tons is the top of the typical residential range. Choose it only when a load calculation shows demand near 60,000 BTU/h, which is common in large homes, open floor plans and high-glass designs. Oversizing a single-stage system this large hurts humidity control, so verify with our tonnage and BTU calculator and a Manual J.
Ducts must handle about 1,750 CFM, and the electrical service must support the outdoor unit plus any large heat strip. This listing offers heat strips from 5 to 20 kW.
Ideal for: Large single-family homes, open-concept and vaulted floor plans, high-load homes, and replacement of existing 5 ton heat pump systems.
Prefer cooling only? Compare the 5 Ton EcoTemp 15.5 SEER2 W5A5S60AKAWA & WCHL605BD Central System, which uses the same air handler with an R-454B air conditioner.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, duct design, window load, occupancy and desired indoor temperature. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | W5H5S60AKAAA — 5 Ton Single-Stage R-454B Heat Pump |
|---|---|
| Indoor Air Handler | WCHL605BD Modular Multipoise ECM Fan Coil (24.5" Cabinet) |
| Application | Residential Ducted Split System Heat Pump — Heating & Cooling |
| Refrigerant | R-454B |
| Compressor | Single-Stage Scroll Compressor |
| Backup Heat | Electric Heat Strip Selected at Checkout (5, 8, 10, 15 or 20 kW) |
| Electrical | 208/230V, Single Phase, 60 Hz Heat Pump |
| Air Handler Electrical | 208/230V, Single Phase |
The W5H5S60AKAAA measures 35" square by 35-1/2" tall, weighs 233 lbs and holds 8.7 lbs of R-454B. It has a 7/8" vapor valve, is rated with a 1-1/8" vapor line, and needs 31.1 MCA with a 50 amp max breaker. The WCHL605BD is a modular two-piece fan coil measuring 59-3/16" H x 24-11/16" W x 22-1/16" D at 210.5 lbs. It has a 3/4 HP multi-tap ECM motor, a 7/8" suction connection and takes a 24" x 20" filter. Single components are also offered: the W5H5S60AKAAA heat pump and WCHL605BD air handler.
Heat Pump & Air Handler Features
W5H5S60AKAAA Outdoor Heat Pump
- Nominal 60,000 BTU/h, the largest in the W5H5S series
- Larger 35" square cabinet with 22.6 sq ft 2-row coil
- 74 dBA sound power (72 dBA with sound shield)
- 1/4 HP condenser fan moving 4,300 CFM
- Single-stage scroll compressor (23.7 RLA)
- Rated with 1-1/8" vapor and 3/8" liquid lines
- Internal pressure relief valve and thermal overload
- Loss-of-charge switch, filter drier and accumulator
- Long-line and low-ambient capable with accessories
- Low-GWP R-454B refrigerant
WCHL605BD ECM Air Handler
- Modular two-piece design for attic and crawlspace installs
- 3/4 HP multi-tap ECM motor, 1,750 CFM nominal
- 24-11/16" wide D cabinet
- A-coil with 7/8" suction connection
- Refrigerant leak detection dissipation system
- Factory-installed R-454B TXV
- Accepts 24" x 20" filters with tool-free access
- Heater options up to 30 kW (24 and 30 kW field convertible)
- Cabinet leakage under 1.4% at 0.5" w.c.
- Pre-painted dark gray galvanized steel casing
Specifications & Manuals
Documentation covers 5 ton vapor line sizing and capacity loss, mounting pad dimensions, modular WCHL605 dimensions, and heater electrical data for single and three-phase kits.
Frequently Asked Questions
Can a 7/8" line set be used instead of 1-1/8" on the 5 ton?
Yes. The W5H5S60AKAAA is rated with 1-1/8", but 7/8" is an acceptable vapor diameter, with 0% cooling capacity loss at 26–50 ft and 1% at 51–80 ft per the spec sheet. 7/8" x 3/8" line sets are offered with this listing.
What is the benefit of the modular WCHL605BD design?
The WCHL605BD comes in two pieces, which makes it easier to carry through attic openings and crawlspace access points before assembly.
How much vertical separation is allowed if the 5 ton unit sits below the air handler?
For the 60 size, total equivalent length is limited to 190 ft at 31–40 ft of separation, 150 ft at 41–50 ft and 110 ft at 51–60 ft. Separation beyond 60 ft is outside the acceptable range.
What pad size does the W5H5S60AKAAA need?
The spec sheet lists a 35" minimum ground-mount pad dimension for the 60 size, larger than the 31-3/16" pad used by the 1.5 to 4 ton models.
What electrical service does the 5 ton outdoor unit need?
The W5H5S60AKAAA requires 31.1 MCA and a 50 amp max time-delay fuse or HACR breaker. The air handler needs a separate circuit sized for the heat strip.
Is there a cooling-only version of this 5 ton EcoTemp system?
Yes. The 5 Ton EcoTemp W5A5S60AKAWA & WCHL605BD Central System pairs the same air handler with a 15.5 SEER2 R-454B air conditioner.
W5H5S Technical Specifications
W5HS5 Installation Instructions
W5HS5 Brochure
WCHL Technical Specifications