decor decor

Summary

Product #179509: $3,050.00
  • Fast Track :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 42068 / 2.5 Ton EcoTemp 14.3 SEER2 R454B Heat Pump Condenser W5H5S30AKAAA (179444) -- 1
  • 42075 / 2.5 Ton EcoTemp R454B ECM Motor Air Handler WCHL305AB (179451) -- 1
3050
$3,050.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
W5H5S30AKAAA, WCHL305AB | The series’ quietest heat pump at 70 dBA, matched with an A-coil ECM air handler

2.5 Ton EcoTemp 14.5 SEER2 R454B Heat Pump System W5H5S30AKAAA, WCHL305AB

· SKU 179509 · AHRI 214101826 · Split System
Capacity
30,000 BTU
Refrigerant
R-454B
SEER2
14.5

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $4,173.00

Our price:

$3,604.00

Sale price:

$3,050.00
You save $1,123.00!

Click For Sale Price

Sale price:

$3,050.00

List price:

$4,173.00

Our price:

$3,604.00
You save: 15% ($1,123.00)
  • SKU: 179509
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • Product Type:
    Split System
  • Tonnage:
    2.5
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    17.5"
  • SEER2:
    14.5
  • Manufacturer Warranty:
    10 Years
Fast Track ?
  • EcoTemp 5 kW Heat Strip Air Handler WBH models EHC05BKN1 / KFFEH0501N05A/ WKF0502X
  • EcoTemp 8 kW Heat Strip Air Handler WBH models EHC07BKN1 /  KFFEH0801N08A / WKF0802X
  • EcoTemp 10 kW Heat Strip Air Handler WBH models EHC10BKN1 /  KFFEH0901N10A / WKF1002X
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • 2.5 Ton EcoTemp 14.3 SEER2 R454B Heat Pump Condenser W5H5S30AKAAA
  • 2.5 Ton EcoTemp R454B ECM Motor Air Handler WCHL305AB
Adding to cart… The item has been added

2.5 Ton EcoTemp 14.5 SEER2 R-454B Heat Pump System – W5H5S30AKAAA & WCHL305AB

At 70 dBA, the W5H5S30AKAAA is the quietest outdoor unit in the EcoTemp W5H5S heat pump series. Paired with the WCHL305AB A-coil air handler, it delivers 30,000 BTU/h of R-454B heating and cooling at 14.5 SEER2. This 2.5 ton system is a strong fit for mid-size homes where the outdoor unit sits near a patio, bedroom window or neighbor's property line.

Is a 2.5 Ton Heat Pump System the Right Size?

A 2.5 ton system fills the gap between smaller 2 ton applications and full 3 ton homes, covering loads around 30,000 BTU/h. Choosing a half-ton size when the load calls for it helps avoid an oversized system that short-cycles. Estimate with our AC tonnage calculator, then confirm with a Manual J.

Check that ductwork can deliver about 875 CFM, the WCHL305AB's nominal airflow. To keep condensate in the drain pan, the spec sheet calls for return static pressure below 0.40" w.c. Backup heat strips are offered in 5, 8 and 10 kW.

Ideal for: Mid-size homes, ranch and split-level houses, homes where outdoor unit noise matters, and replacements of existing 2.5 ton heat pumps.

Need more capacity? Step up to the 3 Ton EcoTemp W5H5S36AKAAA & WCHL365AB Heat Pump System for homes requiring additional heating and cooling capacity.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, duct design, window load, occupancy and desired indoor temperature. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump W5H5S30AKAAA — 2.5 Ton Single-Stage R-454B Heat Pump
Indoor Air Handler WCHL305AB Multipoise ECM Fan Coil (17.5" Cabinet)
Application Residential Ducted Split System Heat Pump — Heating & Cooling
Refrigerant R-454B
Compressor Single-Stage Scroll Compressor
Backup Heat Electric Heat Strip Selected at Checkout (5, 8 or 10 kW)
Electrical 208/230V, Single Phase, 60 Hz Heat Pump
Air Handler Electrical 208/230V, Single Phase

The 2.5 ton size is where the W5H5S line moves to a 3/4" vapor valve and rated 3/4" vapor line, which matches the 3/4" x 3/8" line sets offered with this system. The outdoor unit is 38-7/16" tall on a 31-3/16" square base, weighs 167 lbs and holds 6.1 lbs of R-454B. Indoors, the WCHL305AB is the smallest WCHL with an A-coil. It measures 49-5/8" H x 17-5/8" W and is driven by a 1/2 HP multi-tap ECM motor. Also available separately: the W5H5S30AKAAA heat pump and WCHL305AB air handler.

Heat Pump & Air Handler Features

W5H5S30AKAAA Outdoor Heat Pump

  • 70 dBA sound power, the lowest in the W5H5S series
  • 67 dBA with the accessory sound shield
  • Nominal 30,000 BTU/h heating and cooling capacity
  • Single-stage scroll compressor with internal overload
  • 21.4 sq ft condenser coil face area
  • 3/4" vapor and 3/8" liquid connections
  • Filter drier and suction line accumulator
  • Front-seating service valves for easier service
  • Long-line applications up to 200 ft actual length with accessories
  • Low-GWP R-454B refrigerant

WCHL305AB ECM Air Handler

  • A-coil design with grooved tubes and louvered fins
  • 1/2 HP multi-tap ECM blower, 875 CFM nominal
  • Five speed taps for a wide range of duct systems
  • Refrigerant leak detection dissipation system
  • Factory-installed R-454B TXV
  • 1" thick R-4.2 insulation with vapor barrier
  • Cabinet leakage under 1.4% at 0.5" w.c. (ASHRAE 193)
  • Leak-preventing sweat connections
  • Field-installed heaters from 5 to 20 kW
  • Entry options for high- and low-voltage wiring

Specifications & Manuals

Spec sheets include octave-band sound data for the 2.5 ton outdoor unit, long-line piping limits, WCHL305 airflow tables and electric heater static pressure corrections.

Frequently Asked Questions

How quiet is the W5H5S30AKAAA outdoor unit?

It has a 70 dBA sound power rating, the lowest in the W5H5S heat pump series. With the accessory sound shield, the rating drops to 67 dBA.

What type of coil is in the WCHL305AB?

The WCHL305AB uses an A-coil. For horizontal A-coil installs, the NAMA00125HC horizontal water management kit is listed as an accessory.

Can my existing ductwork handle the 2.5 ton system?

The WCHL305AB is rated at 875 CFM nominal. Ducts should allow that airflow while keeping return static below 0.40" w.c., which helps prevent condensate from blowing out of the drain pan.

What electrical service does the 2.5 ton system require?

The W5H5S30AKAAA needs 16.3 MCA and a 25 amp max breaker. Without electric heat, the WCHL305AB needs 5.3 MCA on a 15 amp circuit. A heat strip increases the air handler's requirement.

How long can the refrigerant line set be?

The W5H5S allows up to 200 ft actual and 250 ft equivalent length. Runs beyond 80 ft on the same level are long-line applications and require additional accessories.

Does this system work with smart thermostats?

The system supports both programmable and standard thermostat controls. Several programmable and Wi-Fi heat pump thermostats are offered as add-ons with this listing.

Customer Review

You Might Also Like