decor decor

Summary

Product #179510: $3,350.00
  • Fast Track :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 42069 / 3 Ton EcoTemp 14.3 SEER2 R454B Heat Pump Condenser W5H5S36AKAAA (179445) -- 1
  • 42076 / 3 Ton EcoTemp R454B ECM Motor Air Handler WCHL365AB (179452) -- 1
3350
$3,350.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
W5H5S36AKAAA, WCHL365AB | Low-profile 3 ton heat pump with a 2-row coil for everyday family comfort

3 Ton EcoTemp 14.5 SEER2 R454B Heat Pump System W5H5S36AKAAA, WCHL365AB

· SKU 179510 · AHRI 214101862 · Split System
Capacity
36,000 BTU
Refrigerant
R-454B
SEER2
14.5

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,406.00

Our price:

$4,108.00

Sale price:

$3,350.00
You save $2,056.00!

Click For Sale Price

Sale price:

$3,350.00

List price:

$5,406.00

Our price:

$4,108.00
You save: 18% ($2,056.00)
  • SKU: 179510
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • Product Type:
    Split System
  • Tonnage:
    3
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    17.5"
  • SEER2:
    14.5
  • Manufacturer Warranty:
    10 Years
Fast Track ?
  • EcoTemp 5 kW Heat Strip Air Handler WBH models EHC05BKN1 / KFFEH0501N05A/ WKF0502X
  • EcoTemp 8 kW Heat Strip Air Handler WBH models EHC07BKN1 /  KFFEH0801N08A / WKF0802X
  • EcoTemp 10 kW Heat Strip Air Handler WBH models EHC10BKN1 /  KFFEH0901N10A / WKF1002X
  • EcoTemp 15 kW Heat Strip Air Handler WBH models EHC15BKB1 /  KFFEH3101C15A / WKF1502BX
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • 3 Ton EcoTemp 14.3 SEER2 R454B Heat Pump Condenser W5H5S36AKAAA
  • 3 Ton EcoTemp R454B  ECM Motor Air Handler WCHL365AB
Adding to cart… The item has been added

3 Ton EcoTemp 14.5 SEER2 R-454B Heat Pump System – W5H5S36AKAAA & WCHL365AB

The EcoTemp W5H5S36AKAAA and WCHL365AB deliver 36,000 BTU/h of R-454B heating and cooling at 14.5 SEER2 for typical mid-size family homes. The 3 ton outdoor unit moves up to a two-row condenser coil yet stays only 31-11/16" tall, the same height as the 1.5 ton model. That low profile works well under windows and decks. The WCHL365AB air handler pairs a 1/2 HP multi-tap ECM blower with an A-coil and a 17-5/8" wide cabinet.

Is a 3 Ton Heat Pump System the Right Size?

Three tons is one of the most common residential sizes. It covers loads around 36,000 BTU/h, though the right size depends on the home itself. Insulation, attic conditions, glass area and duct design can push the load above or below 3 tons. Get a quick estimate with the BTU and tonnage calculator before committing.

Plan the ductwork around the WCHL365AB's 1,050 CFM nominal airflow. If you add a larger heat strip, note the manufacturer's minimum airflow for each heater size. Strips of 5, 8, 10 and 15 kW are offered with this system.

Ideal for: Mid-size family homes, ranch homes, replacements of existing 3 ton heat pumps, and installs where a low-profile outdoor unit is preferred.

Need more capacity? Step up to the 3.5 Ton EcoTemp W5H5S42AKAAA & WCHL425AC Heat Pump System for homes requiring additional heating and cooling capacity.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, duct design, window load, occupancy and desired indoor temperature. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump W5H5S36AKAAA — 3 Ton Single-Stage R-454B Heat Pump
Indoor Air Handler WCHL365AB Multipoise ECM Fan Coil (17.5" Cabinet)
Application Residential Ducted Split System Heat Pump — Heating & Cooling
Refrigerant R-454B
Compressor Single-Stage Scroll Compressor
Backup Heat Electric Heat Strip Selected at Checkout (5, 8, 10 or 15 kW)
Electrical 208/230V, Single Phase, 60 Hz Heat Pump
Air Handler Electrical 208/230V, Single Phase

The W5H5S36AKAAA weighs 172 lbs and ships with 7.6 lbs of R-454B. Its 2-row, 17.2 sq ft condenser coil sits in a 31-3/16" square cabinet. It needs a 19.2 MCA circuit with a 30 amp max breaker, and both the vapor valve and the rated vapor line are 3/4". The WCHL365AB stands 49-5/8" tall, weighs 148 lbs and takes a 16" x 20" filter. Single components are also listed: the W5H5S36AKAAA heat pump and WCHL365AB air handler.

Heat Pump & Air Handler Features

W5H5S36AKAAA Outdoor Heat Pump

  • Nominal 36,000 BTU/h heating and cooling capacity
  • 2-row condenser coil with 20 fins per inch
  • Low 31-11/16" cabinet height
  • 1/4 HP direct-drive condenser fan, 3,500 CFM
  • Single-stage scroll compressor
  • Internal pressure relief valve and thermal overload
  • Loss-of-charge switch for compressor protection
  • Accessory crankcase heater and time-delay relay available
  • Low-ambient cooling capability with accessory kit
  • Low-GWP R-454B refrigerant

WCHL365AB ECM Air Handler

  • 1/2 HP multi-tap ECM motor, 1,050 CFM nominal
  • A-coil with 3/4" suction and 3/8" liquid sweat connections
  • Refrigerant leak detection dissipation system
  • Factory-installed R-454B TXV
  • Tested for condensate disposal beyond AHRI requirements
  • Super-thick R-4.2 insulation with vapor barrier
  • Insulated filter door for an improved air seal
  • Accepts heaters from 5 to 20 kW
  • Pre-painted dark gray galvanized steel casing
  • Multipoise upflow or horizontal installation

Specifications & Manuals

Find 3 ton expanded heating and cooling performance, charging subcooling, accessory usage guidelines and WCHL365 heater minimum airflow requirements in these documents.

Frequently Asked Questions

Is the 3 ton outdoor unit louder than the smaller EcoTemp sizes?

Yes, somewhat. The W5H5S36AKAAA is rated 76 dBA, compared with 70–72 dBA for the 1.5 to 2.5 ton models. The NASA00201SJ sound blanket and careful placement can help near bedrooms.

What minimum airflow is needed with a 15 kW heat strip?

The WCHL spec sheet lists a 920 CFM minimum for the 36 size with a 15 kW heater. Speed tap 4 (white wire) is reserved for electric heat and must stay on tap 4.

What subcooling should be used when charging the 3 ton system?

The W5H5S product data lists 10°F (5.6°C) of required subcooling for the 36 size with a TXV-type expansion device.

Will the 3 ton condenser fit under a window or deck?

The W5H5S36AKAAA is only 31-11/16" tall on a 31-3/16" square base, the same height as the 1.5 ton model. Allow the clearances shown in the spec sheet.

Is a crankcase heater included with the 3 ton heat pump?

It is an accessory (NASA00601CH for sizes 18 to 36). The manufacturer requires one for low-ambient cooling and long-line applications.

Who is the 3 ton EcoTemp system a good match for?

Homeowners and contractors replacing a 3 ton system, or sizing a mid-size home near 36,000 BTU/h, who want a low-profile outdoor unit and a simple single-stage R-454B system.

Customer Review