4 Ton EcoTemp 15 SEER2 R-454B Heat Pump System – W5H5S48AKAAA & WCHL485AC
For larger homes, the EcoTemp W5H5S48AKAAA heat pump and WCHL485AC air handler deliver 48,000 BTU/h of R-454B heating and cooling at 15 SEER2. The outdoor unit has a 21.4 sq ft two-row coil and the largest factory charge in the series. Indoors, a 3/4 HP multi-tap ECM blower moves 1,400 CFM nominal. It is a solid pick for two-story homes, larger ranch floor plans and replacements of tired 4 ton systems.
Is a 4 Ton Heat Pump System the Right Size?
A 4 ton system serves loads near 48,000 BTU/h, common in larger homes with more glass, higher ceilings or a second floor. Size from the heat load, not the floor plan, because a well-insulated large home can need less than expected. Our AC tonnage and BTU calculator is a quick first check.
At this size, airflow setup matters. Goodman notes that airflow above 400 CFM per ton on 48 and 60 size fan coils can blow condensate off the coil, so the installer should set the speed tap accordingly. Heat strips from 5 to 20 kW are offered for backup heat.
Ideal for: Larger single-family homes, two-story houses, homes with high ceilings or large window areas, and replacements of existing 4 ton heat pumps.
Need more capacity? Step up to the 5 Ton EcoTemp W5H5S60AKAAA & WCHL605BD Heat Pump System for the largest residential heating and cooling loads.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, duct design, window load, occupancy and desired indoor temperature. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | W5H5S48AKAAA — 4 Ton Single-Stage R-454B Heat Pump |
|---|---|
| Indoor Air Handler | WCHL485AC Multipoise ECM Fan Coil (21" Cabinet) |
| Application | Residential Ducted Split System Heat Pump — Heating & Cooling |
| Refrigerant | R-454B |
| Compressor | Single-Stage Scroll Compressor |
| Backup Heat | Electric Heat Strip Selected at Checkout (5, 8, 10, 15 or 20 kW) |
| Electrical | 208/230V, Single Phase, 60 Hz Heat Pump |
| Air Handler Electrical | 208/230V, Single Phase |
The W5H5S48AKAAA stands 38-7/16" tall on a 31-3/16" square base and weighs 231 lbs. It holds 10.5 lbs of R-454B, the most of any unit in the series, and is rated with a 7/8" vapor line. It needs a 29.4 MCA circuit with a 50 amp max breaker. The WCHL485AC is a single-piece fan coil at 53-7/16" H x 21-1/8" W x 22-1/16" D and 182 lbs, with a 7/8" suction connection and a 20" x 20" filter. Buy separately if needed: the W5H5S48AKAAA heat pump and WCHL485AC air handler.
Heat Pump & Air Handler Features
W5H5S48AKAAA Outdoor Heat Pump
- Nominal 48,000 BTU/h heating and cooling capacity
- 15 SEER2 when matched with the WCHL485AC
- 21.4 sq ft, 2-row condenser coil with 12 circuits
- 1/4 HP condenser fan moving 3,800 CFM
- Single-stage scroll compressor (22.4 RLA)
- 10.5 lb factory R-454B charge for a 15 ft line set
- Internal pressure relief valve and thermal overload
- Filter drier, accumulator and loss-of-charge switch
- Optional NASA00101SJ sound blanket for sizes 42–60
- Low-ambient cooling to 0°F with approved kits
WCHL485AC ECM Air Handler
- 3/4 HP multi-tap ECM motor, 1,400 CFM nominal
- Single-piece 21-1/8" C cabinet, 53-7/16" tall
- A-coil with 7.42 sq ft face area
- Refrigerant leak detection dissipation system
- Factory-installed R-454B TXV
- Integrated motor controls with 90-second off-delay
- Accepts heaters up to 20 kW single phase
- Also supports 24 and 30 kW field-convertible heaters
- R-4.2 foil-free insulation with vapor barrier
- Multipoise with horizontal hanging provisions
Specifications & Manuals
These sheets cover 4 ton outdoor electrical data and vertical separation limits, WCHL485 airflow by speed tap, condensate guidelines and the full electric heater table.
Frequently Asked Questions
Are there airflow cautions for installing the WCHL485AC horizontally?
Yes. For horizontal 42–60 size installs, supply static should be above 0.20" w.c. and return static below 0.40" w.c. to keep condensate in the drain pan.
What is the largest heat strip available for the 4 ton system?
Up to 20 kW is offered with this listing. The WCHL48 size also accepts the 24 kW and 30 kW EHC25BHCF and EHC30BHCF heaters, which require larger electrical service.
How much refrigerant is in the W5H5S48AKAAA?
It ships with 10.5 lbs (4.76 kg) of R-454B, sized for a 15 ft line set. Adjust the charge for longer runs per the installation instructions, using 13°F subcooling.
How far below the air handler can the 4 ton outdoor unit sit?
For the 48 size with the outdoor unit below the indoor unit, total equivalent length is limited to 230 ft at 51–60 ft of vertical separation and 160 ft at 61–70 ft. Separation beyond 70 ft is outside the acceptable range.
What kind of home typically needs a 4 ton heat pump?
Homes with loads near 48,000 BTU/h, often larger single-story or two-story homes with significant glass or high ceilings. A load calculation confirms the fit.
Which crankcase heater fits the 4 ton heat pump?
The NASA00501CH crankcase heater is listed for the 42, 48 and 60 sizes. It is required for low-ambient cooling and long-line applications.
W5H5S Technical Specifications
W5HS5 Installation Instructions
W5HS5 Brochure
WCHL Technical Specifications
