Product #172949: $4,890.00
  • Crating :
  • Heat Strip:
  • Roof Curb :
  • Curb Adapter :
  • Economizer or Fresh Air Damper :
4890
$4,890.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?

3 Ton Rheem R454B 13.4 SEER2 208/230V 3Ph Heat Package Unit, RHPCYB036ACT000AAAA0

· SKU 172949 · AHRI 214803177 · Package AC
Capacity
36,000 BTU
Refrigerant
R-454B
Operating Mode
Heat Pump
Average Rating:
List price: $6,591.00

Sale price:

$4,890.00
You save $1,701.00!
  • SKU: 172949
  • Availability:
    Usually Ships in 7 to 10 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • Product Type:
    Package AC
  • Tonnage:
    3
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Airflow Direction:
    Downflow/Horizontal
  • Voltage:
    208-230V 3PH
Crating
  • Crating
  • 10kW Rheem RACB Commercial 240V 3Ph Heat Strip, RXJJ-DC10CP
  • 15kW Rheem RACB Commercial 240V 3Ph Heat Strip, RXJJ-DC15CP
  • 20kW Rheem RACB Commercial 240V 3Ph Heat Strip, RXJJ-DC20CP
Roof Curb
  • 3 - 6 Ton Rheem 14" Roof Curb ALL Models, RXKG-DCC14
Curb Adapter
Economizer or Fresh Air Damper
  • 3-6 Ton Rheem RGEC Manual Fresh Air Damper, RXRF-ACA1
  • 3-6 Ton Rheem RGEC Motorized Fresh Air Damper, RXRF-ACB1
  • 3-6 Ton Rheem RGEC Horizontal Economizer w/ Single Enthalpy, RXRD-01MCHAM3
  • 3-6 Ton Rheem RGEC Downflow Economizer w/ Single Enthalpy, RXRD-01MCDAM3
Adding to cart… The item has been added

Rheem 3 Ton R-454B Packaged Heat Pump — RHPCYB036ACT000AAAA0

The Rheem RHPCYB036ACT000AAAA0 is a 3-ton Commercial Classic Series packaged heat pump that provides both R-454B air conditioning and reverse-cycle heat-pump heating from one self-contained rooftop or slab-mount cabinet. Wired for 208/230V 3-phase power, it delivers 34,200 BTU/h AHRI net cooling at 10.6 EER2 / 13.4 SEER2 and supplies approximately 36,000 BTU/h of heat-pump heating at 47°F, with capacity that tapers as outdoor temperatures fall. Built around a single-stage scroll compressor, all-microchannel coils, a reversing valve with demand defrost, factory refrigerant leak detection, and a direct-drive ECM blower with convertible downflow or horizontal airflow, it is a compact all-electric heating-and-cooling solution for small-commercial spaces on 208/230V 3-phase service.

Is a 3-Ton Heat Pump the Right Size?

This heat pump pairs 34,200 BTU/h of net cooling with reverse-cycle heating from the same refrigerant circuit, so it is sized primarily on the cooling load. For many light-commercial buildings 3 tons suits roughly 1,200 to 1,800 sq ft, though occupancy, ventilation, and heat gain move the real requirement. Its heating output at 47°F is approximately 36,000 BTU/h and declines in colder weather.

Because a heat pump's capacity drops as it gets colder, most commercial installations add a field-installed electric heater kit for supplemental heat below the balance point and for emergency heat during defrost. Size the cooling side from a commercial load calculation, then size the backup electric heat to cover the building's design heating load. Confirming the load (rather than using floor area alone) keeps the compressor off short cycles and protects comfort and humidity control.

Ideal for: Small retail storefronts, offices, bank branches, and light-commercial suites on 208/230V 3-phase power that want all-electric, no-gas heating and cooling — especially in mild-to-moderate climates or where building electrification is a goal.

Cooling only? If you don't need heat-pump heating, the 3-ton RACC 208/230V 3-phase straight-air package unit is the cooling-only equivalent. Need the other voltage? See the 3-ton 460V 3-phase heat pump.

Recommended applications are general guidelines only. Actual cooling and heating requirements depend on insulation, ventilation, occupancy, solar gain, climate, and design temperatures. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Model Number RHPCYB036ACT000AAAA0
Product Type Commercial Classic Series Packaged Heat Pump (Cooling + Heating)
Nominal Cooling 3 Tons — 34,200 BTU/h AHRI net cooling
Cooling Efficiency 10.6 EER2 / 13.4 SEER2
Heat-Pump Heating approximately 36,000 BTU/h at 47°F (declines at lower outdoor temperatures)
Refrigerant R-454B (A2L, factory charged — approx. 84 oz)
Compressor Single-Stage Scroll Compressor with Reversing Valve
Defrost Demand defrost
Nominal Airflow 1,200 CFM — direct-drive ECM, convertible downflow or horizontal
Electrical 208/230V, 3-Phase, 60 Hz
Minimum Circuit Ampacity 23 A
Max Overcurrent Protection 30 A
Manufacturer Warranty 5-Year Compressor / 1-Year Parts (Commercial)

The RHPCYB036ACT000AAAA0 ships as one factory-assembled, wired, and run-tested cabinet with R-454B charged — set it, connect power and ducting, and commission. Add a field-installed electric heater kit for supplemental and emergency backup heat. Need cooling only? See the matching 3-ton RACC straight-air unit, browse more Rheem equipment, or the full packaged unit lineup.

Unit Features

Cooling, Compressor & Coils

  • Single-stage scroll compressor factory-charged with low-GWP R-454B refrigerant
  • Reverse-cycle heat-pump operation delivers both cooling and heating from one system
  • MicroChannel outdoor and indoor coils with TXV metering and a solid-core filter drier
  • Factory-installed A2L refrigerant leak detection with automatic mitigation
  • Rated 10.6 EER2 / 13.4 SEER2 at 34,200 BTU/h AHRI net cooling
  • Demand-based defrost with high- and low-pressure protection and Smart Logic
  • Cooling operation to 125°F ambient; convertible downflow or horizontal airflow
  • 18-gauge galvanized cabinet with forkable base rails and gasket-protected panels

Heat-Pump Heating, Controls & Serviceability

  • Heat-pump heating of approximately 36,000 BTU/h at 47°F, tapering as outdoor temperature drops
  • Reversing valve with demand defrost for efficient cold-weather heating
  • Field-installed electric heater kits available for supplemental and emergency backup heat
  • Direct-drive constant-torque ECM indoor blower delivering 1,200 nominal CFM
  • CoreCommand control with PlusOne diagnostics and dual 7-segment LED display
  • Ships with four disposable 2 x 16 x 16 in. filters; MERV 8 and MERV 13 available
  • 208/230V, 3-Phase, 60 Hz power: 23 A minimum circuit ampacity, 30 A maximum overcurrent protection
  • Ships wired and run-tested; pre-wired for a field- or factory-installed economizer

Specifications & Manuals

Product documentation includes RHPC series technical specifications, installation instructions, and warranty information to assist with equipment selection, installation, and service. This unit carries a Rheem limited warranty; see the warranty document above for full coverage terms.

Frequently Asked Questions

What cooling and heating does the RHPCYB036ACT000AAAA0 provide?

It delivers 34,200 BTU/h AHRI net cooling (10.6 EER2 / 13.4 SEER2) and about 36,000 BTU/h of heat-pump heating at 47°F, with output that declines as it gets colder. Size it from a commercial load calculation and add electric backup heat for the coldest design conditions.

What power does the RHPCYB036ACT000AAAA0 require?

It is wired for 208/230V, 3-Phase, 60 Hz and needs a 23 A minimum circuit ampacity with a 30 A maximum overcurrent protection device. The other-voltage build is the 3-ton 460V 3-phase version (RHPCYB036ADT000AAAA0).

Does a heat pump need backup heat?

In most commercial applications, yes. A heat pump's output falls as the outdoor temperature drops, so a field-installed electric heater kit is typically added for supplemental heat below the balance point and for emergency heat during defrost. The right backup size depends on your climate and design heating load.

Is this a cooling-only unit or does it heat too?

It both heats and cools. A reversing valve lets the refrigerant cycle run in reverse to provide heating as well as cooling, all-electric, with no gas. If you only need cooling, the 3-ton RACC 208/230V 3-phase straight-air package unit is the cooling-only equivalent.

Can this unit be installed downflow and horizontal?

Yes. Airflow is field-convertible between vertical downflow (for curbed rooftop openings) and horizontal side-flow, so the same unit works on a curb or a slab with side duct connections.

Is it charged with R-454B and does it have leak detection?

Yes. It is factory-charged with low-GWP R-454B (an A2L refrigerant, approximately 84 oz) and includes a factory-installed refrigerant leak detection system that triggers a fault and mitigation sequence if a leak is sensed.